Danfoss Comfort II GVX, Comfort II VVX Fact sheet

Fact sheet

Comfort II GVX and VVX

Floor or wall-mounted cylinder systems for single-family houses for central and district heating

Application

The Comfort II GVX and VVX units are ready-made substations for heating and domestic hot water for indirect systems in single-family house, which are connected to a district heating network.

Configuration

The Comfort II range can be configured according to local requirements and legislation, however as a standard the substations are prefabricated with plate heat exchanger, domestic hot water cylinder, thermostats, ball valves, differential pressure controller, expansion vessel, non-re- turn and safety valves, fitting piece for heat meter, circulation pump, manometers and thermometers, strainers, sensor pockets, pressure relief valve as well as a functional cover in a new design. The Comfort II GVX comes with a complete cover as standard delivery. The cover for the VVX must be ordered separately. The cylinder cover is delivered fully assembled and the bottom part cover is supplied unassembled.

Design

The Comfort II GVX is a ready-made solution, which is prepared for floor-mounting.

The technical part featuring the substation control is placed below the cylinder. The cover consists of a cylinder cover, two side plates as well as a detachable front cover for the technical part.This facilitates heat meter readings and maintenance.

The Comfort II VVX is a wall-mounted solution, which is suitable for mounting in a installation cabinet. The VVX is supplied unassembled, consisting of a separate cylinder as well as a technical part, for mounting on site. The VVX can, if ordered separately, be supplied with cylinder cover and bottom part cover. The Comfort II VVX is especially suitable for implementation with a Danfoss Redan DR II distribution unit.

Domestic hot water cylinder

The Comfort II range is supplied with a 100 or a 150 liter cylinder with Danish VA approval. The highly efficient cylinder is double-enamelled and supplied with a heating coil, which is designed for the use of district heating as heating source for domestic hot water heating. The cylinder is fully insulated with environmentally friendly PU foam, which minimizes the heat loss and ensures the best possible operating economy.

FEATURES AND BENEFITS

Compact district heating substation with hot water cylinder

Plenty of DHW, 100/150 l cylinder

Equipped with a highly efficient plate heat exchanger

Totally insulated cylinder, min. heat loss

Superior heating capacity

Fine operating economy

Complies with modular measures

Wall-mounted solutions, which are suitable for implementation with DR II distribution units

Domestic hot water circulation

The Comfort II is prepared for DHW circulation. For new systems it is recommended to establish domestic hot water circulation, which ensures that domestic hot water is available immediately when tapping starts.

Service friendly and easy to install

Suitable piping and consistent use of union nuts to connect pipes facilitates the servicing and mounting of the substation.

Reading and initial adjustment

Thermometers are placed in the front part of the substation, easily read. Thermostats for adjustment of the heating and the domestic hot water temperature are placed conveniently to facilitate the adjustment.

www.danfoss.com

Danfoss Comfort II GVX, Comfort II VVX Fact sheet

CIRCUIT DIAGRAM – EXAMPLE

 

1.

Plate heat exchanger, HE

16.

Expansion vessel

 

2.

DHW cylinder

17.

Air valve

 

4.

Differential pressure controller

23.

Sensor pocket for heat meter

 

5.

Strainer

24.

Flexible piece for heat meter

 

6.

Non-return valve

 

¾ x 110-165 mm

 

7.

Ball valve

29.

Thermostat Danfoss RAVK, HE

DHW

8.

A-labelled pump - HE, 230V AC

30.

Valve, Danfoss VMA 15, HE

9.

Plug

31.

Thermostat Danfoss RAVK, DHW

 

 

11.

Safety valve, HE, 2.5 bar

32.

Valve, Danfoss VMA 15, DHW

 

12.

Safety valve, DHW, 10 bar

43.

Blind plate

Circ.

13.

Thermometer

---------------------------------------------

 

13A.

Thermometer

62.

Non-return valve (not part of dly)

DCW

14.

Pressure relief valve

64.

Circ. pump (not part of dly)

15.

Manometer, 2.5 bar

 

 

DH

Supply

DH

Return

Technical parameters:

 

Nom. pressure

 

(prim/sec):

PN 16 / PN 3

Max. supply temp:

120 ºC

Min. ∆P:

See capacity examples

Weight:

 

GVX 100/150 ltr.

130/155 kg

VVX 100/150 ltr.

90/115 kg

Dimensions (mm):

Floor-mounted w/cover: H 1885 xW 550 x D 560 Wall-mounted w/cover: H 1617 xW 550 x D 560

Fitting piece for heat meter:

¾ x 110 x 165 mm flex. return

Connections sizes:

G ¾

 

1

13

 

560

560

 

Floor-mounted

Wall-mounted

 

GVX

VVX

 

side view

side view

 

<![if ! IE]>

<![endif]>1617

<![if ! IE]>

<![endif]>1603

<![if ! IE]>

<![endif]>1885

<![if ! IE]>

<![endif]>1872

 

 

 

<![if ! IE]>

<![endif]>496

 

<![if ! IE]>

<![endif]>764

 

 

<![if ! IE]>

<![endif]>268

 

60 65 65 65 65

65 65 100

 

 

 

 

 

 

<![if ! IE]>

<![endif]>44,5

GVX/VVX

 

 

 

 

60 65 65 65 65 65 65 100

 

top view

 

 

 

 

<![if ! IE]>

<![endif]>4,5

 

 

Front

Connections

 

550

 

 

 

 

HE

Note! Units with heat exchanger

Supply

for floor heating are supplied with

 

connection pipes for radiators

 

before heat exchanger for direct

 

connection.

HE

 

Return

 

Connections:

1. District heating (DH) supply

2. District heating (DH) return

3. Circulation

4. Heating (HE) return

5. Heating (HE) supply

6. Domestic hot water (DHW)

7. Domestic cold water (DCW)

Options

Art. No.

Cylinder cover (for GVX and VVX)

936.1201

Complete cover, for wall-mounted VVX

936.1231

Bottom part cover, for wall-mounted VVX

936.1240

Complete cover, for floor-mounted GVX

936.1211

Bottom part cover, for floor-mounted GVX

936.1220

 

 

 

 

 

 

 

 

DHW: Capacity examples, 10°C/50 °C

 

Heating: Capacity examples

Total

 

Supply

Return

Constant flow

Constant

 

 

Temperatures

Pressure loss

Flow

 

 

 

 

 

Cylinder

flow

flow

rate

capacity

Type

Capacity

 

 

Primary

Secondary

Primary

Primary

volume, ltr.

primary

primary

 

kW

GVX/VVX

kW

 

2

2

 

°C

°C

l/h

 

 

 

°C

°C

(total )bar

(total ) l/h

 

70

30

245

11,4

100-26

15

30

30

0,55

470

100

65

30

204

9,5

150-26

15

30

30

0,55

470

 

60

30

172

8,0

100-241

15

40

40

0,39

400

 

70

30

245

11,4

100-241

15

40

40

0,39

400

150

65

30

204

9,5

 

 

 

 

 

 

 

60

30

172

8,0

 

 

 

 

 

 

© Danfoss | DHS-SRMT/ PL | 2018 . 05