Danfoss Comfort II GTD/VTD, Comfort II GS/VS Fact sheet

Fact sheet
Comfort II GTD/VTD and GS/VS
Floor or wall-mounted cylinder systems for single-family houses for central and district heating
FEATURES AND BENEFITS
• Compact district heating substation with hot water cylinder
• Plenty of DHW, 100/150 l cylinder
• Superior heating capacity
• Fine operating economy
• Complies with modular measures
• Wall-mounted solutions, which are suitable for implementation with DR II distribution units
Application
The Comfort II GTD/GS and VTD/VS units are ready-made solutions for heating and domestic hot water for direct systems in single-family house, which are connected to a district heating network.
Configuration
The Comfort II range can be configured according to local requirements and le­gislation, however as a standard the sub­stations are prefabricated with domestic hot water cylinder, ball valves, differen­tial pressure controller, non-return and safety valves, fitting piece for heat meter, thermometers, strainers, sensor pockets, pressure relief valve as well as a functio­nal cover in a new design. The Comfort II GTD/GS come with a complete cover as standard delivery. The cover for the VTD/ VS must be ordered separately. The cylin­der cover is delivered fully assembled and the bottom part cover is supplied unas­sembled.
Design
The Comfort II GTD/GS are ready-made solutions, which are prepared for flo­or-mounting.
The technical part featuring the substa­tion control is placed below the cylinder. The cover consists of a cylinder cover, two side plates as well as a detachable front cover for the technical part. This facilitates heat meter readings and maintenance. The Comfort II VTD/VS are wall-moun-ted solutions, which are suitable for mounting in an installation cabinet. The VTD/VS are supplied unassembled, consisting of a se­parate cylinder as well as a technical part, for mounting on site. The VTD/VS can, if ordered separately, be supplied with cy­linder cover and bottom part cover. The Comfort II VTD/VS are especially suitable for implementation with a Danfoss Redan DR II distribution unit.
Domestic hot water cylinder
The Comfort II range is supplied with a 100 or a 150 liter cylinder with Danish VA approval. The highly efficient cylinder is double-enamelled and supplied with a heating coil, which is designed for the use of district heating as heating source for domestic hot water heating. The cylinder is fully insulated with environmentally fri­endly PU foam, which minimizes the heat loss and ensures the best possible opera­ting economy.
Domestic hot water circulation
The Comfort II range is prepared for DHW circulation. For new systems it is recom­mended to establish domestic hot water circulation, which ensures that domestic hot water is available im- mediately when tapping starts.
Service friendly and easy to install
Suitable piping and consistent use of uni­on nuts to connect pipes facilitates the servicing and mounting of the substation.
Reading and initial adjustment
Thermometers are placed in the front part of the substation, easily read. Thermostats for adjustment of the heating and the do­mestic hot water temperature are placed conveniently to facilitate the adjustment.
www.heatwwwwww.danfoss.com
764
1885
1872
560
268
D
B
C
D
B
C
560
D
C
B
A
87
6
5
4
3
764
1885
1872
560
268
60 65 65 65 65 65 65 100
D
B
C
ISO 2768 - mK
General tolerance accuracy
Weight
293,634 kg
E
F
Designation
Comfort2 GVX Kbh.
Replace
Design
14-11-2011
JJ
Approval
Danfoss Redan A/S
Projection
Scale
Size
Material
1:10
A3
Danfoss Standard
CIRCUIT DIAGRAM – EXAMPLE
NOTE! Components in the dotted areas are fitted only in Comfort II VS and GS
DHW
7
64 62
Circ.
DCW
7
12
6
19
24A
DH
7
5
23
Supply
DH
14
7
24
23
4 5
Return
Technical parameters:
Nom. pressure (prim/sec): PN 10 / PN 103 Max. supply temp: 120 ºC Min. ∆P: See capacity examples
Weight:
GTD 100/150 ltr. 120/145 kg (incl. cover)
GS 100/150 ltr. 125/150 kg (incl. cover)
VTD 100/150 ltr. 8 0/105 kg (incl. cover)
VS 100/150 ltr. 85/110 kg (incl. cover)
Dimensions (mm):
Floor-mounted w/cover: H 1885 x W 550 x D 560 Wall-mounted w/cover: H 1617 x W 550 x D 560
Fitting piece for heat meter:
Connections sizes:
¾ x 110 x 165 mm flex. re turn
G ¾
43A
13A
7
32
43
43
1885
764
268
60 65 65 65 65 65 65 100
2
7
560
Connections
2. DHW cylinder
4. Differential pressure controller
5. Strainer
6. Non-return valve
7. Ball valve
8. A-labelled pump - HE, 230V AC (only GS/VS)
12. Safety valve, DHW, 10 bar
13. Thermometer 13A. Thermometer
14. Pressure relief valve
17. Air valve (only GS/VS)
19. Tap valve (with plug)
17
30
6
1617
1872
496
44,5
GTD/GS VTD/VS
550
8
1603
23. Sensor pocket for heat meter
24. Flexible fitting piece for heat meter ¾” x 110-165 mm 24A. Fitting pipe for heat meter
30. Thermostat, HE (only GS/VS)
32. Thermostat, DHW
43. Connection pipe with blind plate before mixing circuit 43A. Blind plate
---------------------------------------------
62. Non-return valve (not part of dly)
64. Circ. pump (not part of dly)
13
14
7
HE Supply
13
7
HE
Note! GS/VS units are supplied with connection pipes for radiators before heat exchanger for direct connection.
Return
Connections:
1. District heating (DH) supply
2. District heating (DH) return
3. Circulation
4. Heating (HE) return
5. Heating (HE) supply
6. Domestic hot water (DHW)
7. Domestic cold water (DCW)
Options Art. No.
Cylinder cover (for GTD/GS and VTD/VS) 936.1201 Complete cover, wall-mounted VTD/VS 936.1231 Bottom part cover, wall-mounted VTD/VS 936.1240 Complete cover, floor-mounted GTD/GS 936.1211 Bottom part cover, floor-mounted GTD/GS 936.1220
DHW: Capacity examples, 10°C/50 °C
Cylinder
volume, ltr.
Supply
flow
primary
°C
Return
flow
primary
°C
70 30 245 11, 4 GTD/VTD100 15 30 30 0,55 470
100
65 30 204 9, 5 GTD/VTD150 15 30 30 0,55 470 60 30 172 8,0 GTD/VTD100 15 40 40 0,39 400
150
70 30 245 11, 4 GTD/VTD150 15 40 40 0,39 400 65 30 204 9, 5 GS/ VS100 8 40 5 60 30 172 8,0 GS/ VS150 8 40 5
© Danfoss | DHS-SRMT/ PL | 2018 . 05
Constant flow
rate
l/h
Constant
capacity
kW
Heating: Capacity examples Tot al
Temperatures
Capacity
kW
Primary
Typ e
GS/ VS100 15 40 10 GS/V S150 15 40 10
°CSecundary
°C
1
1
1
1
Pressure loss
Primary
(total2) bar
0,16 290 0,16 290 0,29 400 0,29 400
Flow
Primary
(total2) l/h
VL.IE.W2.02