Danfoss BB, BE, BF, BG, BN Data sheet

Data Sheet
Solenoid coil Type BB, BE, BF, BG and BN
The Clip-on coils are available for the entire range of Danfoss solenoid valves
The coils are specially designed to operate in the aggressive environment of high humidity and temperature uctuations that you nd in most refrigeration systems.
The Clip-on fastening system ensures a faultless installation and makes the coils easy to mount and dismount. A Danfoss Clip-on coil can be mounted without any tools at all, and it is simple to dismount the coil by means of a screwdriver.
The Clip-on coils are available for the entire range of Danfoss solenoid valves for refrigeration, freezing and air conditioning purposes.
Features
• Encapsulated coils with long operating life, even under extreme conditions.
• Standard coils for AC or DC.
• Standard coils available with 3-core cable, terminal box or DIN plugs.
• Standard coils from 12 V to 420 V, 50, 60 or 50/60 Hz.
• Standard coils dimensioned for max. opening dierential pressure (MOPD) of up to 38 bar.
• Coils can be tted without the use of tools.
AI237186440089en-000802
Data
Solenoid coil type
1m 3-core
cable
Terminal box
DIN spade
and
protection
cap
DIN spade
1m 3-core
cable
Terminal
box
DIN spade
and
protection
cap
DIN spade
Terminal box IP67
BFBEBGBGBEBBBFBEBEBBBN
Enclosure
IP67
IP67
IP67
IP67
IP20
IP00
IP67
IP67
IP20
IP00
IP67
Polution de­gree
44443344333
Conductor area [mm2]
0.75
0.75 - 1.5
0.75 - 1.5
0.75 - 1.5
0.75 - 1.5
0.75 - 1.5
0.75
0.75 - 1.5
0.75 - 1.5
0.75 - 1.5
0.75 - 1.5
Cable size [mm]
Ø6.6
Ø6.0 - Ø11
Ø6.0 - Ø11
Ø6.0 - Ø11
Ø6.0 - Ø11
Ø6.0 - Ø11
Ø6.6
Ø6.0 - Ø11
Ø6.0 - Ø11
Ø6.0 - Ø11
Ø6.0 - Ø11
Rated im­pulse volt­age [kV], if altitude < 4000 m
44444444444
Humidity [R.H.]
0 − 100%
0 − 100%
0 − 100%
0 − 100%
0 − 97%
non-con­densation condition
0 − 97%
non-con­densation condition
0 − 100%
0 − 100%
0 − 97%
non-con­densation condition
0 − 97%
non-con­densation condition
0 − 100%
Type of con­trol
11111111111
Safety clas-
sication
Class I
Class I
Class I
Class I
Class I
Class I
Class I
Class I
Class I
Class I
Class I
Max. alti­tude above sea level [m]
4000
4000
4000
4000
4000
4000
4000
4000
4000
4000
4000
Solenoid coil, Type BB, BE, BF, BG, and BN
Product specication
Technical data
Table 1: Solenoid coil type
NOTE:
For DIN plug, impulse withstand voltage is 3.1 kV for 2000 m < Altitude < 4000 m
Connection
3-core cable
The external thread in the screwed cable entry suits exible steel hose or corresponding cable protection (3 x 0.75 mm2).
Terminal box
Leads are connected to terminal screws in the terminal box. The box is tted with a Pg 13.5 screwed entry for 6 - 14 mm cable. Max. lead cross section: 2.5 mm2.
DIN plugs
The three pins on the coil can be tted with spade tabs, 6.3 mm wide (to EN175301-803A). The two current carrying pins can also be tted with spade tabs, 4.8 mm wide. Max. lead cross section: 1.5 mm2. Use of the protective cap supplied will prevent inadvertent contact with live parts.
DIN socket
(to EN175301-803A) Leads are connected in the socket. The socket is tted with a Pg 11 screwed entry for 6 - 12 mm.
© Danfoss | Climate Solutions | 2021.08 AI237186440089en-000802 | 2
94
Danfoss M18F03
45
57
47
71
57
45
46
86
51
45
57
47
28
110
45
57
68
Solenoid coil, Type BB, BE, BF, BG, and BN
Dimension and weight
Figure 1: Terminal box 10 W , Weight 0.29 Kg
Figure 2: Cable 10 W , Weight 0.29 Kg
Figure 3: DIN socket 10 W , Weight 0.24 Kg
Figure 4: Terminal box 12 - 20 W , Weight 0.55 Kg
© Danfoss | Climate Solutions | 2021.08 AI237186440089en-000802 | 3