Application
Ordering
The Basic insulation overlap panels of 20 and
35 mm are 2 m² (1 + 1 m² - folded) and serve as
heat and sound insulation. The surface of the
insulation overlap panels is capable of taking
stress and can be walked on. It forms a suitable
base for the Danfoss BasicRail system and for the
pipe lay-out.
They are easy to install and the strong foil is a
technically ecient base for cement and liquid
screed. To compensate for pipes on the oor and
for deeper insulation a double layer is laid e.g.
with EPS 035 DEO 20 mm.
The grid shown on the insulation foil is 5 cm.
Product Typ e Code no.
Basic Insulation overlap panel, 20 mm FH-IMB 088X0071
BasicRail for 16 x 2 mm pipes, 2 m FH-BRA 088X0040
BasicRail for 20 x 2.25 mm pipes, 3 m FH-BRB 088X0042
Rail clips for BasicRail FH-BRD 088X0043
Basic perimeter insulation, 150 mm, 8 mm FH-BK 088X0065
Technical specications
VDCSE502
Insulation Overlap Panel 35 mm 20 mm
Foil
Insulation (expanded polystyrene) EPS 045 DES 35-3 EPS 045 DES 20-2
Panel size 1000 x 2000 mm, folded 1000 x 2000 mm, folded
Total thickness (dL / dB) 35 mm / 32 mm 20 mm / 18 mm
Thermal conductivity (λ) 0.045 W/mK 0.045 W/mK
Thermal resistance (R) 0.77 m2 K/W 0.44 m2 K/W
Impact sound insulation 29 dB 26 dB
Maximum active load 4 kN/m
0.2 mm,
3 cm aps on two sides
2
0.2 mm,
3 cm aps on two sides
2
4 kN/m
© Danfoss | FHH | 2015.09 | 1
Accessories
Product Typ e Code no.
Basic movement gap strip, 2 m FH-ACA 088X0066
Basic pipe sleeve, 40 cm FH-ACB 088X0067
Note on HBCD
This product contains a substance included on the
candidate list according to article 59 (1,10) of
regulation EC No. 1907/2006 (‘REACH’) in a
concentration above 0.1% w/w: ameproong
agent, hexabromocyclododecane.
HBCD is also present on the Annex 14 list.
Danfoss A/S
Floor Heating Hydronics • Ulvehavevej 61 • DK-7100 Vejle • Denmark • Phone: +45 7488 8500 • Fax: +45 7488 8501
heating@danfoss.com • www.oorheating.danfoss.com
Danfoss ca n accept no respons ibility for pos sible errors in ca talogues, bro chures and other pr inted material. Da nfoss reserves t he right to alter its p roducts with out notice. This als o applies to produ cts
already o n order provided t hat such alteratio ns can be made with out subsequenti al changes being n ecessary in spe cications alr eady agreed.
All trade marks in this mate rial are proper ty of the respec tive companies . Danfoss and the Dan foss logotyp e are trademark s of Danfoss A/S. Al l rights reserv ed.
2 | © Danfoss | Danfoss | FHH | 2015.09
VDCSE502