Danfoss BasicGrip Application guide

Application Sheet
1
2
3
4
5
6
BasicGrip
Carpet / Tiles / Parquet / Laminate / Synthetics Cement-screed
1 Carpet / tiles / parquet
2 Cement-screed 85 mm
3 FH composite pipe / FH PE-RT pipe (16 mm)
5 Basic perimeter insulation
6 BasicGrip PE-string (18 mm)
Technical Data
Floor finish
Construction height
Weight
Thermal resistance (R)
Thermal transmission coefficient (U)
Distribution load
Point load (≥ 20 cm²)
Impact subsonic noise reduction
Application area
Requirements & special features
Additional insulation
Construction
NA mm Carpet / tiles / parquet / laminate / synthetics
96 mm Height excluding floor finish
~ 176 kg / m² Weight excluding floor finish
0, 31 m²K / W Thermal resistance value for BasicGrip panel
2,08 W / m²K
≤ 2,0 kN / m²
≤ 2,0 kN
dB
Rooms in residential bulildings and houses; bedrooms and wards in hospitals; bedrooms in hotels and hostels kitchens and toilets. Correponding to category A of EN 1991. Office areas. Correponding to category B of EN 1991.
The screed thicknesses must be adjusted in case of higher design load or point load values. Structural sealing according to EN 13967 must be placed beneath the floor panel in case of structures facing the ground, and otherwise on the unfinished floor. Observe all installation instructions and manufacturer’s instructions.
For thermal resistance table and insulation thickness, please refer to the Basic handbook.
Referring to EN 1264, ISO EN 140-8, EN 1991, EN 13813, EN 13967 and local building regulations.
Be aware that building regulations can specify better thermal insulation
Calculated value according to DIN 4109; applies to concrete slabs thicker than 12 cm (DIN 4109: m2 > 276 kg/m2).
Construction number 562
VAELF202 © Danfoss 10/2009