Instructions
Accessories P - for AMV 15, AMV 16
1
087R9105
3
2
087R9105
7369286-0 SIBC R&D EI.97.I1.5Q © Danfoss 9/00 1
ENGLISH DEUTSCH
Potentiometer settings:
With the module mounted in the actuator
(figs. 1 and 2):
Settings fig. 3:
1. Connect actuator and valve
2. Apply voltage to the actuator
terminals N and 1, and allow the
actuator to run to the end stop.
3. Turn the potentiometer carefully and
clockwise until it stops.
4. Test and adjust the setting, if
necessary.
NOTE:
It is only possible to make use of the full
potentiometer range if the applied valve
has a stroke of 15 mm.
SLOVENSKO
Nastavitev potenciometra
Montirajte modul na pogon (sliki 1 in 2):
Nastavitev potenciometra - slika 3
1. Montirajte pogon na ventil.
2. Priklopite napajanje pogona na
sponki N in 1. Tako pustite da se
pogon zapelje do skrajne lege.
3. Previdno zavrtite potenciometer do
konène lege v smeri urinega kazalca.
4. Preizkusite in po potrebi fino
nastavite.
Potentiometereinstellungen:
Nach der Montage vom Modul im Antrieb
(Abb. 1 und 2)
Einstellungen (Abb. 3):
1. Antrieb und Ventil montieren (Abb. 1
und 2).
2. Die Antriebsklemmen N und 1 mit
Spannung versorgen, und den
Antrieb zum Endausschalter laufen
lassen.
3. Die Einstellung prüfen und wenn
notwendig eine Feineinstellung
vornehmen.
Beachten Sie bitte:
Der gesamte Potentiometerbereich kann
dann nur genutzt werden, sofern der
Hub des gewählten Ventils 15 mm
beträgt.
Opomba:
Polni obseg potenciometra se lahko
uporabi samo z ventili, ki imajo 15 mm
hoda.
2 EI.97.I1.5Q © Danfoss 9/00 SIBC R&D 7369286-0