Danfoss 3022 User guide

3022 Electro-Mechanical Timeswitch
(For 3-Port Priority Diverter Valves)
INSTALLATION INSTRUCTIONS
SPECIFICATION
Power Supply : 220/240 Vac, 50 Hz Switch Action : 2 x SPST, type 1B Switch Rating : 220/240 Vac, 50 Hz, 3(1)A Timing Accuracy : +/- 1 min/month Enclosure Rating : IP30 Max. Ambient Temperature : 55°C Designed to meet BS EN60730-2-7 Overall Dimensions : 102mm wide, 210mm high, 60mm deep Construction : Class 1 Control Pollution Situation : Degree 2 Rated Impulse Voltage : 2.5Kv Ball Pressure Test : 75°C
The unit must be installed by a competent electrician and the installation should conform to IEE Wiring Regulations. The supply to this unit should be wired through full disconnect in accordance with BS EN60730-1, i.e. one which provides an air gap of at least 3mm in both poles of the mains, e.g. a 13 amp plug and unswitched socket, or a switched, fused outlet with neon; either tted with a 3 amp (max.) fuse.
INSTALLATION AND WIRING INSTRUCTIONS
1. Unscrew xings rings from selector switches, move all four tappets to top of dial, remove outer case.
2. Slacken two screws securing plug-in module to backplate and separate module from backplate by pulling upwards.
3. Fix backplate to wall (3 hole xing).
4. Referring to wiring diagrams opposite make electrical connections as shown (as applicable).
5. Secure cables under cable clamp.
6. Plug in programmer module and re-tighten the two retaining screws
- do not overtighten.
7. Remove cut-out from outer case as required, replace outer case and xing rings. Check that outer case sits squarely on body and is not distorted by uneven wall surface.
8. Select left hand switch to ‘ON’ and light up boiler according to manufacturers instructions.
9. Rotate dial clockwise through at least one complete revolution and check that all four tappets are clear of outer case aperture.
10. Operating checks:- Select left hand switch to ‘TIMED’. Rotate dial by hand to observe that both boiler and pump operate together during ‘ON’ periods. Select left hand switch to ‘ON’. Select right hand switch to ‘HEATING PRIORITY’; under this condition the room thermostat should take preference over the cylinder thermostat (i.e. hot water will not be available until the room thermostat is satised: in other words when the room thermostat is calling for heat the DIVERTER VALVE will be energised irrespective of the state of the cylinder thermostat). Now select ‘HOT WATER PRIORITY’. Under this condition the cylinder thermostat takes preference over the room thermostat and heating will only be available when the cylinder thermostat is satised (i.e. when the cylinder thermostat is calling for heat the DIVERTER VALVE will remain unenergised irrespective of the state of the room thermostat). When both cylinder and room thermostats are satised check that the boiler, and pump are electrically ‘dead’ and the diverter valve is sprung open to the cylinder.
EXTERNAL WIRING TO DANFOSS RANDALL HEATPLAN CONTROLS PACK
PRIORITY
SWITCH
HW
1 2 3
(N)
Danfoss Randall RMT230 Room Stat
L
L
PumpBoiler
N
N
SELECTOR SWITCH
HTG
2
4
1
4 5
213
ON OFF
TIMED
6
Danfoss
Randall ATC
Cylinder Stat
L
Diverter
Valve
N
Time
Switch
7
3022 Terminals
Mains
N
Supply
L
1
3022 Electro-Mechanical Timeswitch
(For 3-Port Priority Diverter Valves)
USER INSTRUCTIONS
3022 PROGRAMMER OPERATING INSTRUCTIONS
1) Setting the programmer (Example 1)
i) Decide when you want the
‘ON’ periods. While griping the Dial Knob slide the dial tappets rmly as shown. The tappets may be quite stiff to move. If yo u wan t the swit ch ‘ON’ between 7am and 10am and between 5pm (1700 hours) and 11pm (2300 hours), set the tap pe ts as shown (A to 7, B to 10, C to 17 and D to 23).
Remember:­ Red tappets switch ON Blue tappets switch OFF
ii) Using the Dial Knob rotate the dial completely at least twice,
clockwise only, to clear the mechanism.
‘A’ at the rst ON time in the day (7) ‘B’ at the rst OFF time in the day (10) ‘C’ at the second ON time in the day (17) ‘D’ at the second OFF time in the day (23)
2) Setting the Time (Example 2)
Suppose it is 2pm (1400 hours)
wh en y ou a re m akin g th is adjustment. Using the dial knob rotate the dial clockwise only until ‘14’ on the dial is next to the ‘Time’ mark, as shown.
Remember that you will have
to reset the time after a power cut and also when the clocks change by one hour in spring and autumn.
Important: Any adjustment to the time setting must be made by
rotating the dial clockwise only.
3) Selecting the Programme Required
The two selector switches operate entirely independently of each other
as follows:
The 3-way selector switch with positions marked TIMED, OFF and ON
is used to operate and override the tappet settings on the clock as follows:
TIMED (Selector switch in the up position). The clock will switch your
system ON and OFF according to times at which you have set the four tappet arms. See example 1.
OFF (Selector switch in the middle position). This position will
completely override the tappet setting and the ON-OFF function of the timeclock enabling you to switch your system o.
ON (Selector switch in the down position). This position operates in
the opposite way to the OFF position. It will completely override the tappet settings and ON-OFF function of the timeclock enabling you to switch your system ON (e.g. during the winter when the timeclock is in an o position).
The 2-way priority switch is set to give the emphasis or priority on
the service which you require. On a cold morning for example you may want the heating to come on rst. In this case the switch is set to ‘HEATING PRIORITY’.
Or you may require two baths in succession, so ‘WATER PRIORITY’ would
be selected. Whichever priority is chosen, it will remain in that state until the switch is moved to the other priority position.
To obtain water only, select ‘ WATER PRIORITY’ and turn the room
thermostat down to the lowest setting.
Danfoss Randall can accept no responsibility for possible errors in catalogues, brochures and other printed material, and reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without subsequent changes being necessary in specications already agreed.
Danfoss Randall Ltd,
Ampthill Road, Bedford, MK42 9ER Tel: 01234 364621 Fax: 01234 219705 Email: danfossrandall@danfoss.com Website: www.danfoss-randall.co.uk
2
Part No: 7452 Iss.05 05/05