Danfoss 176F3166, 176F3167 Installation Instructions Manual

Description
The top fan assembly in D3h/D4h drives includes 1 fan within a fan housing or secured under a grill. The top fan assembly in E3h/E4h drives consists of 2 fans within a single fan housing. The top fan replacement kit contains all parts required to replace 1 fan in the top fan assembly.
Kit Ordering Numbers
176F3166 Top fan IP20 DC 80x25 mm
176F3167 Top fan IP20 DC 80x38 mm
Table 1.1 Numbers for the Top Fan Kit
Items Supplied
The top fan replacement kit contains the following:
1 fan
Installation instructions
Safety Information
Only qualied, Danfoss authorized personnel are allowed to install the parts described in these installation instructions. Handling of the drive and its parts must be done in accordance with the corresponding operating guide.
WARNING
ELECTRICAL SHOCK HAZARD
VLT® FC series drives contain dangerous voltages when connected to mains voltage. Improper installation, and installing or servicing with power connected, can cause death, serious injury, or equipment failure.
To avoid death, serious injury, or equipment failure:
Only use
qualied
electricians for the installation.
Disconnect the drive from all power sources before installation or service.
Treat the drive as live whenever the mains voltage is connected.
Follow the guidelines in these instructions and local electrical safety codes.
WARNING
DISCHARGE TIME
The drive contains DC-link capacitors, which can remain charged even when the drive is not powered. High voltage can be present even when the warning LED indicator lights are
o.
Failure to wai t for the
specied
time listed in Tab l e 1 .2 after power has been removed before performing service or repair work can result in death or serious injury.
1. Stop the motor.
2. Disconnect AC mains and remote DC-link supplies, including battery back-ups, UPS, and DC-link connections to other drives.
3. Disconnect or lock motor.
4. Wait for the capacitors to discharge fully. Refer to Tab l e 1 .2 .
5. Before performing any service or repair work, use an appropriate voltage measuring device to make sure that the capacitors are fully discharged.
Voltage [V ] Power rating [kW] (hp)
(normal overload)
Enclosure Minutes to
discharge
380–500 90–250
(125–350)
D1h–D8h 20
380–500 315–500
(450–650)
E1h–E4h 40
525–690 55–315
(60–350)
D1h–D8h 20
525–690 355–710
(400–750)
E1h–E4h 40
Table 1.2 Discharge Time for Enclosures D1h–D8h and E1h–E4h
Installation Instructions
Top Fan Kit for D3h/D4h and E3h/E4h Drives VLT
®
FC Series FC 102, FC 103, FC 202, FC 302
Danfoss A/S © 04/2018 All rights reserved. MI35N202
Installation Instructions
1 Screw (T25) 4 Fan cable and connector
2Fan grill 5Top vent
3 Fan 6 Cable access hole
Illustration 1.1 Top Fan with Grill in D3h/D4h Drives
Installation Instructions
Top Fan Kit for D3h/D4h and E3h/E4h Drives VLT
®
FC Series FC 102, FC 103, FC 202, FC 302
2
Danfoss A/S © 04/2018 All rights reserved. MI35N202
Loading...