Installation Instructions
LOP Connection and Set-up
®
VLT
Items Supplied
•
•
•
DriveMotor FCP/FCM 106
Local operating panel (LOP), 175N0128 IP 65, see
Illustration 1.1.
Fixture for LOP, 175N2717 (included in 175N0128),
see Illustration 1.2.
LOP cable.
Illustration 1.1 Local Operation Panel (LOP) 175N0128 IP 65
Illustration 1.2 Fixture for LOP 175N2717 (included in 175N0128)
Danfoss A/S © 09/2015 All rights reserved. MI03L202

Installation Instructions
LOP Connection and Set-up
®
DriveMotor FCP/FCM 106
VLT
Safety Instructions
Refer to VLT® DriveMotor FCP 106 and FCM 106 Operating
Instructions for detailed information about safety precautions
for installation.
WARNING
DISCHARGE TIME
The frequency converter contains DC-link capacitors, which
can remain charged even when the frequency converter is
not powered. High voltage can be present even when the
warning LED indicator lights are
specied time after power has been removed before
performing service or repair work can result in death or
serious injury.
1. Stop the motor.
2. Disconnect AC mains, permanent magnet type
motors, and remote DC-link supplies, including
battery back-ups, UPS, and DC-link connections to
other frequency converters.
3. Wait for the capacitors to discharge fully, before
performing any service or repair work. The duration
of waiting time is
specied
Failure to wait the
o.
in Ta b l e 1 . 1 .
Connection to FCP 106 or FCM 106
1. Connect the LOP as shown in Ta b le 1 . 2 and
Illustration 1.3.
2. After completing connections, cut o or isolate
excess wire.
3. Connect terminal 27 V to +24 V or set
parameter 5-12 Terminal 27 Digital Input to [0] No
operation.
Terminal Dual-speed
operation
18 Purple Gray
19 –
27 Brown
29 Green
12 Red
50 Yellow
55 Blue
Table 1.2 Electrical Connections
Dual-mode
operation
Dual-direction
operation
Volt age
[V]
3x400 0.55–7.5 4
Table 1.1 Discharge Time
1) Power ratings relate to NO, see VLT
Operating Instructions.
Power Range
1)
[kW]
®
DriveMotor FCP 106 and FCM 106
Minimum waiting
time
(min)
Illustration 1.3 LOP Connections to FCP 106 or FCM 106
2
Danfoss A/S © 09/2015 All rights reserved. MI03L202