The ConMed Linvatec 26” and 32” LCD Medical Monitor
Instruction Manual
(VP4726, VP4726F, VP4732 and VP4732F)
Manuel d'instruction du moniteur médical LCD
ConMed Linvatec 66 cm et 81 cm
(VP4726, VP4726F, VP4732 et VP4732F)
ConMed Linvatec 26-Zoll und 32-Zoll LCD-Monitor
Bedienungsanleitung
(VP4726, VP4726F, VP4732 und VP4732F)
Monitor medicale LCD 26" e 32” ConMed Linvatec
Manuale di istruzioni
(VP4726, VP4726F, VP4732 e VP4732F)
Manual de instrucciones del monitor LCD médico ConMed
Linvatec de 26 y 32 pulgadas
(VP4726, VP4726F, VP4732 y VP4732F)
E
F
G
I
S
E
Proprietary Information
This manual contains information deemed proprietary to Linvatec Corporation. The
information contained herein, including all of the designs and related materials, is the sole
property of ConMed Linvatec and/or its licensors. ConMed Linvatec and/or its licensors
reserve all patent, copyright and other proprietary rights to this document, including all
design, manufacturing methodology and reproduction.
This document, and any related materials, is confidential and is protected by copyright laws
and shall not be duplicated, transmitted, transcribed, stored in a retrieval system, or
translated into any human or computer language in any form or by any means, electronic,
mechanical, magnetic, manual or otherwise, or disclosed to third parties, in whole or in part,
without the prior express written consent of ConMed Linvatec.
ConMed Linvatec reserves the right to revise this publication and to make changes from time
to time in the contents hereof without obligation to notify any person of such revision or
changes, unless otherwise required by law.
Linvatec is a trademark or registered trademark of ConMed Linvatec
Linvatec Corporation 2009. All Rights Reserved. Printed in USA
Record the Model and Serial Numbers of the LCD Monitor(s) and date received. Retain
for future reference.
Monitor Model No.Serial NoDate
Monitor Model No.Serial NoDate
Monitor Model No.Serial NoDate
t is recommended that personnel study this
manual before attempting to connect,
operate, adjust and/or clean the ConMed
Linvatec 26” and 32” Medical LCD Monitors
(VP4726, VP4726F, VP4732 and VP4732F future designation as VP47XX and VP47XXF).
The safe and effective use of this equipment
requires the understanding of and compliance
with all warnings, precautionary notices, and
instructions marked on the product, and
included in this manual.
VP47XXF Monitors are identical to VP47XX
Monitors except they are equipped with Optical
input connectors. See “1.19 OPTICAL
(available on VP47XXF Monitors Only)” on
page E-33 for connector information.
1.1Intended Use
VP47XX and VP47XXF Medical LCD Monitors
are used to display live and recorded images
captured with a medical grade camera system or
previously recorded using various recording
devices.
1.2Warnings and Precautions
E
The words WARNING, PRECAUTION, and
NOTE carry special meanings and they should
be read carefully.
WARNING: The safety and/or health
of the patient, user, or a third party is at
risk. Comply with this warning to avoid
injury to the patient, user, or third party.
PRECAUTION: This contains
information concerning the intended use
of the device or accessory. Damage to
the equipment is possible if these instructions
are not followed.
NOTE: A note is added to provide additional,
focused, information.
1.2.1Warnings
1.This equipment is designed for use
by medical professionals completely familiar
with the required techniques and instructions
for use of the equipment. Prior to using the
device, read and follow all warning and
precautionary notices and instructions
marked on the product and included in
this manual.
2.Do not attempt to open or service
the monitor, as this may void your
warranty. There are no userserviceable parts inside. Removing
the cover may introduce an electric
shock hazard by exposing you to dangerous
high voltages or other risks. If the system
malfunctions, return it for service
immediately.
E-1
E
3.Dangerous voltages are present
inside the monitor. The unit should
be used only in rooms that comply
with recommendations concerning
electrical safety when used for medical
purposes (as stated in IEC 60601 Series and
UL 60601-1).
4.Never insert anything metallic into
the cabinet openings of the monitor.
Doing so may cause electric shock.
5.System installation shall be in accordance
with the requirements of IEC 60601-1-1,
The Standard for Safety Requirements of
Medical Electrical Systems.
6.This equipment is not suitable for
use in the presence of flammable
anesthetic mixture with air,
oxygen, or nitrous oxide.
7.Some disinfectants and cleaning agents
vaporize to form explosive mixtures and, if
such agents are used, the vapor must be
allowed to disperse before the monitor is
put to use.
8.Before connecting the AC power cord to
the DC adapter outlet make sure the voltage
designation of the DC adapter corresponds
to the local electrical supply.
9.Disconnect monitor prior to applying
cardiac defibrillation to patient.
10. This monitor should not share an electrical
outlet or grounding with life supporting or
life sustaining equipment.
11. This monitor may not be used in connection
with life support equipment.
12. Equipment grounding is vital for safe
operation. Plug power cord into a properly
earthed mains supply outlet whose voltage
and frequency characteristics are
compatible with those listed on the monitor
or in this manual. Do not use plug adapters
or extension cords; such devices defeat the
safety ground and could cause injury.
13. Grounding reliability is achieved only when
the monitor is connected to a “hospital
only” or “hospital grade” receptacle.
Inspect routinely and do not use if damage
is discovered.
14. If one or more mains powered units are
connected simultaneously to one socket by
the means of a distribution box, the sum of
the individual leakage currents may exceed
the tolerated limits.
15. Be sure to hold the plug, not the
cord, when disconnecting the
monitor from an electric socket.
Doing so may cause electric shock.
16. Do not touch signal input, signal output or
other connectors, and the patient
simultaneously.
17. If your monitor does not operate normally,
in particular, if there are any unusual
sounds or smells coming from it, unplug it
immediately and return for service.
18. For the protection of service personnel, and
for safety during transportation, all devices
and accessories that are returned for repair
must be prepared for shipment as described
in “1.6 Returning the Monitor” on page
E-6 of this manual. The manufacturer has
the right to refuse to carry out repairs if the
product is contaminated.
E-2
1.2.2Precautions
Rx ONLY
1.United States Federal law
restricts sale of this device to or
on the order of a physician.
2.The monitor should only be used in
compliance with its intended use.
3.Do not use the monitor with incompatible
equipment not authorized by ConMed
Linvatec. Doing so may void certifications
and/or warranties.
4.The warranty becomes void and the
manufacturer is not liable for dire ct or
resulting damage if:
• The monitor or the accessories are
improperly used, prepared or maintained;
• The instructions in the manual are not
adhered to;
• Non-authorized persons open and / or
perform repairs, adjustments or
alterations to the monitor;
NOTE: Receipt of technical documentation
from the manufacturer does not authorize
individuals to perform repairs, adjustments,
or alterations to the monitor or accessories.
Only authorized service personnel may
perform repairs, adjustments or alterations on
the monitor and accessories. Any violation will
void the manufacturer’s warranty. Authorized
service technicians are trained and certified
only by the manufacturer.
5.Prior to each use the monitor and all
associated equipment must be inspected for
proper operation.
6.Do not expose the monitor to moisture,
operate in wet areas, or place liquids on or
above unit.
7.Electrical cords and attaching cables used
with the monitor must be appropriate for the
rated voltage and current, and in compliance
with all international, national, and local
electrical codes and regulations pertaining to
the use of medical devices.
8.Ensure that the available mains voltage
matches the mains voltage data on the rear
of the monitor which is located near the
appliance inlet module.
9.Do not excessively bend or kink the
instrument power cord.
10. Handle all equipment carefully. If the
monitor is dropped or otherwise damaged,
return it immediately for service.
11. Openings in the monitor cabinet are
provided for ventilation. To prevent
overheating, these openings should not be
blocked or covered.
12. Thoroughly clean the monitor as needed
(reference “2.3 Cleaning Instructions” on
page E-34).
E
E-3
E
13. External equipment that will be connected to
signal input and signal output ports or other
connectors shall comply with relevant IEC
standard (i.e., IEC 60950 for IT equipment
and IEC 60601 series for medical electrical
equipment). In addition, all such
combinations / systems - shall comply with
the standard IEC 60601-1-1 (Safety
requirements for medical electrical systems).
Any person who connects external
equipment to signal input and signal output
ports or other connectors has formed a
system and is therefore responsible for the
system to comply with the requirements of
IEC 60601-1-1. If in doubt, contact a
qualified technician or your local
representative.
(a) Reorient or relocate the receiving
device.
(b) Increase the separation between the
equipment.
(c) Connect the equipment into an outlet
on a circuit different from that to which
the other devices are connected.
(d) Consult the manufacturer or field
service technician for assistance.
1.3Environmental Directives
WEEE Directive [2002/96/EC] on
Waste Electrical and Electronic
Equipment
The Directive on Waste Electrical and
Electronic Equipment obliges manufacturers,
importers, and/or distributors of electronic
equipment to provide for recycling of the
electronic equipment at the end of its useful life.
Do not dispose of WEEE in unsorted municipal
waste.
The WEEE symbol on the product or its
packaging indicates that this product must not
be disposed of with other waste. Instead, it is
your responsibility to dispose of your waste
equipment by handing it over to a designated
collection point for the recycling of Waste
Electrical and Electronic Equipment. The
separate collection and recycling of your waste
equipment at the time of disposal will help
conserve natural resources and ensure that it is
recycled in a manner that protects human health
and the environment. For more information
about where you can drop off your medical
equipment at the end of its useful life for
recycling, please contact ConMed Linvatec.
E-4
1.4Symbol Definitions
Rx ONLY
3
Power Standby / ON
Follow instructions for use.
Precaution or warning notice
Flammable Anesthetics - Risk of
explosion if used in the presence of
flammable anesthetics
Fragile
This side up
E
Electrical hazard. Dangerous
voltages are present within the
cabinet. Never attempt to repair
the equipment. Only trained
service personnel may remove
the cover, or obtain access to the
system components.
Alternating Current.
Direct Current
Protective Earth (ground).
Warning - For continued
protection against risk of fire,
replace only with same type and
rating fuse.
Waste Electronics and Electrical
Equipment (WEEE) Symbol.
Regarding European Union endof-life of product.
RF Symbol. Non-ionizing
Electromagnetic Radiation
Caution: Federal Law restricts
this device to sale by or on the
order of a physician.
GPIO
PACS
PIP
PBP
IPX1
Maximum Stacking
Keep Dry
Temperature limits for storage and
transport
Humidity limits for storage and
transport
Pressure limits for storage and
transport
General Purpose Input / Output
Picture Archive Communications
System
Picture in Picture
Picture By Picture (side by side
images)
Indicates that the device is
protected against the effects of
vertically falling water.
E-5
E
1.5Unpacking and Inspecting the
Monitor
Upon receipt, carefully unpack the monitor and
accessories. Ensure contents are complete and
are free from damage. If any damage is noted
contact your ConMed Linvatec Customer
Service Representative. Save ALL packaging
materials; they may be needed to verify any
claims of damage by the shipper.
VP47XX / VP47XXF LCD Monitor:
•1 - DVI Cable, 6 ft. (IM9021)
•1 - BNC Cable (8175-06)
•1 - AC Adapter (VP4726PS for 26”
Monitor or VP4732PS for 32”
Monitor)
•2 - DC Cable Terminal male / female
(Optional)
•4 - Screws FH M4x12 (Screws for Vesa
mount - Optional)
•2 - Ferrite Core,
ZCAT2035-0930A-M-K (Optional)
•1 - Instruction Manual
1.6Returning the Monitor
If it becomes necessary to return the monitor,
always use the original packaging. The
manufacturer does not take responsibility for
damage that has occurred during transportation
if the damage was caused by inadequate
transport packaging.
Contact ConMed Linvatec Customer Service for
Return Authorization PRIOR to shipping your
monitor for service.
Please make sure that all required information
has been supplied.
• Owner’s Name
• Owner’s Address
• Owner’s Daytime Telephone Number
• Device type and model.
• Serial Number
• Detailed explanation of the damage.
The power cord is sold separately and is
packaged in a separate box.
•C7104 Power Cord — 115VAC
•C7105 Power Cord — 230VAC
E-6
E
❶
❸❹❺
❻❼❽❾
❷
1.7System Indicators
1.7.1Front Panel On-Screen Display
(OSD) Button Functionality
❶ “POWER” Button - Press to set the
monitor to Normal Mode or Stand-by Mode.
❷ Power Status Indicator - Indicator is off
when monitor is in stand-by mode, and is
illuminated green when the monitor is
activated.
❸ Up Arrow - With the OSD deactivated, press
this area to increase the brightness of the
monitor. With the OSD activated, press this
area to move the cursor upward in a menu.
❹ Left Arrow - With the OSD deactivated,
press this area to decrease the contrast of
the monitor. With the OSD activated, press
this area to enter a sub-menu and decrease
the adjustment of the selected function.
➎ MENU Button - With the OSD deactivated,
pressing this button activates the OSD menu.
With OSD activated, pressing this button
exits the main menu or sub-menu.
➏ Down Arrow - With the OSD deactivated,
press this area to decrease the brightness of
the monitor. With the OSD activated, press
this area to move the cursor downward.
❼ Right Arrow - With the OSD deactivated,
press this area to increase the contrast of the
monitor. With the OSD activated, press this
area to enter a sub-menu and increase the
adjustment of the selected function.
❽ INPUT Button - Used to change the
monitor’s signal source; select DVI
OPTICAL / DVI DIGITAL / DSUB
ANALOG / SDI / YPbPR / RGBS /
SVIDEO / CVIDEO. With OSD
deactivated, press this button to switch
signal inputs.
➒ PIP Button - Pressing this button enables
the Picture-In-Picture function. Select PIP,
PBP1, PBP2.
E-7
E
11
1213141516
17
18
❶❷❸❹❺❻❼❽
❾
1011
12
13
1415
17
18
16
1.7.2Rear Panel
❶ AC / DC IN Jack
❷ ON / OFF Switch
❸ OPTICAL IN (OPTIONAL) Connector
(Available only on VP47XXF Models)
❹ DVI IN Connector
➎ DVI OUT Connector
➏ VGA IN Connector
❼ GPIOConnector
❽ RS232C Connector
➒ HD SDI IN Connector
➓ HD SDI OUT Connector
RED / Pr Connector
GREEN / Y Connector
BLUE / Pb Connector
C-SYNC / H-SYNC Connector
VS (V-SYNC) Connector
S-VIDEO / Y Connector
S-VIDEO / C Connector
Composite (C) VIDEO Connector
E-8
1.8Monitor Operation
1.Connect the DC input jack to the DC IN
connector on the back of the monitor.
2.Plug the female end of the AC Power Cord
into the AC Inlet of the DC Adapter.
3.Plug the AC Power Cord into a Hospital
Grade outlet.
4.Connect the appropriate video source to the
monitor.
5.Apply power to all connected peripheral
devices.
6.Turn the monitor on by pressing the power
switch on the back of the monitor.
7.Set your preferred settings using the On-
Screen Menus listed on the following
pages.
E
E-9
E
1.9On-Screen Display Menus
1.9.1DSUB ANALOG/RGBS Input Source
Adjust Menu
❶ BRIGHTNESS - Increase or decrease the
brightness (Range: 0~100).
❷ CONTRAST - Increase or decrease the contrast
(Range: 0~100).
❸ SATURATION - Changes the tone of the color
(Range: 0~100).
❹ COLOR - Changes the richness of the color
(Range: Green 0~50, Red 0~50).
➎ CLOCK - Increase or decrease the sampling
frequency (Range: 0~100).
➏ PHASE - Increase or decrease the phase level
(Range: 0~100).
❼ BACK LIGHT - Increase or decrease the back
light dimming level (Range: 0~100).
❽ AUTO ADJUST - Fit to the most appropriate
screen on the D-SUB Analog signal.
Color Temp Menu
❶ MODE - Change the color temperature mode:
6500K, 5600K, USER. When USER is selected, a
sub-menu displays allowing the user to adjust the
RED, GREEN or BLUE balance.
❷ RED - Red balance- Only works with USER mode
(Range: 0~100).
❸ GREEN - Green balance- Only works with USER
mode (Range: 0~100).
❹ BLUE - Blue balance- Only works with USER
mode (Range: 0~100).
E-10
Image Menu
❶ IMAGE SIZE - Change the image size (Scaling
mode) (Full; Fill Aspect; 1:1; Normal).
❷ H POSITION - Adjust the horizontal (left or right)
position of the displayed source image
(Range: 0~100).
❸ V POSITION - Adjust the vertical (up or down)
position of the displayed source image
(Range: 0~100).
❹ GAMMA - Adjust GAMMA value (VIDEO,
BYPASS, 1.8, 2.0, 2.2, 2.4, 2.6, PACS).
➎ FILTER - Set the sharpness of the image (Softest,
Soft, Normal, Sharp, Sharpest).
➏ OVER SCAN - Adjust the displayed size ( 0~8)
❼ IMAGE SETTING - Allow selection of one of
five user defined image presets.
❽ ZOOM / PAN - Enlarge the image.
➒ FREEZE FRAME - Freezes the image.
❷ OSD POSITION - Change the OSD position.
❸ DURATION - Adjust time until the OSD Menu
will disappear after adjusting the duration
(5, 10, 20, 30, 60, 90, 120, 180, 240 seconds).
❹ RESET SETTINGS - Changes all the OSD values
to factory out-going status.
➎ AUTO SOURCE SELECT - Disable or enable
auto source select. (ON: Searches through all
possible input sources until an active video source
is found. OFF: Video input is manually selected.)
➏ USER NAME ENTRY - Change the name of a
Preset to the Users Name, etc.
E-11
PIP Menu
E
❶ LAYOUT - Changes the OSD layout (Single, PIP,
PBP1, PBP2).
For each LAYOUT selection, the following Sub-menus
are available:
❷ SOURCE - Changes the secondary source.
❸ SIZE - Changes the PIP size (Small, Large).
❹ POSITION - Changes the PIP location.
➎ SWAP - Swaps the position and size of the Primary
and Secondary image.
E-12
1.9.2DVI OPTICAL / DVI DIGITAL Input
Source
Adjust Menu
❶ BRIGHTNESS - Increase or decrease the
brightness (Range: 0~100).
❷ CONTRAST - Increase or decrease the contrast
(Range: 0~100).
❸ SATURATION - Changes the tone of the color
(Range: 0~100).
❹ COLOR - Changes the richness of the color
(Range: Green 0~50, Red 0~50).
➎ BACK LIGHT - Adjust the back light dimming
level (Range: 0~100).
E
Color Temp Menu
❶ MODE - Change the color temperature mode:
6500K, 5600K, USER. When USER is selected, a
sub-menu displays allowing the user to adjust the
RED, GREEN or BLUE balance.
❷ RED - Red balance- Only works with USER mode
(Range: 0~100).
❸ GREEN - Green balance- Only works with USER
mode (Range: 0~100).
❹ BLUE - Blue balance- Only works with USER
mode (Range: 0~100).
E-13
Image Menu
E
❶ IMAGE SIZE - Change the image size
(Scaling mode) (Full; Fill Aspect; 1:1; Normal).
❷ GAMMA - Adjust GAMMA value (VIDEO,
BYPASS, 1.8, 2.0, 2.2, 2.4, 2.6, PACS).
❸ FILTER - Set the sharpness of the image (Softest,
Soft, Normal, Sharp, Sharpest).
❹ OVER SCAN - Adjust the displayed size ( 0~8).
➎ IMAGE SETTING - Change the image setting
(PRESET 1, PRESET 2, USER 1, USER 2, USER 3).
➏ ZOOM / PAN - Enlarge the image.
❼ FREEZE FRAME - Freezes the image.
will disappear after adjusting the duration
(5, 10, 20, 30, 60, 90, 120, 180, 240 seconds).
❹ RESET SETTINGS - Changes all the OSD values
to factory out-going status.
➎ AUTO SOURCE SELECT - Disable or enable
auto source select. (ON: Searches through all
possible input sources until an active video source
is found. OFF: Video input is manually selected.)
➏ USER NAME ENTRY - Change the name of a
Preset to the Users Name, etc.
E-14
PIP Menu
❶ LAYOUT - Changes the OSD layout (Single, PIP,
PBP1, PBP2).
For each LAYOUT selection, the following Sub-menus
are available:
❷ SOURCE - Changes the secondary source.
❸ SIZE - Changes the PIP size (Small, Large).
❹ POSITION - Changes the PIP location.
➎ SWAP - Swaps the position and size of the Primary
and Secondary image.
1.9.3YPbPr Input Source
Adjust Menu
❶ BRIGHTNESS - Increase or decrease the
brightness (Range: 0~100).
❷ CONTRAST - Increase or decrease the contrast
(Range: 0~100).
E
❸ SHARPNESS - Adjust the sharpness of the video
image (Range: 0~100).
❹ SATURATION - Changes the tone of the color
(Range: 0~100).
➎ COLOR - Changes the richness of the color
(Range: Green 0~50, Red 0~50).
➏ BACK LIGHT - Increase or decrease the back
light dimming level (Range: 0~100).
❼ CLOCK - Increase or decrease the sampling
frequency (Range: 0~100).
❽ PHASE - Increase or decrease the phase level
(Range: 0~100).
E-15
Color Temp Menu
E
❶ MODE - Change the color temperature mode:
6500K, 5600K, USER. When USER is selected, a
sub-menu displays allowing the user to adjust the
RED, GREEN or BLUE balance.
❷ RED - Red balance- Only works with USER mode
(Range: 0~100).
❸ GREEN - Green balance- Only works with USER
mode (Range: 0~100).
❹ BLUE - Blue balance- Only works with USER
mode (Range: 0~100).
Image Menu
❶ IMAGE SIZE - Change the image size
(Scaling mode) (Full; Fill Aspect; 1:1; Normal;
Anamorphic).
❷ H POSITION - Adjust the horizontal (left or right)
position of the displayed source image
(Range: 0~100).
❸ V POSITION - Adjust the vertical (up or down)
position of the displayed source image
(Range: 0~100).
❹ GAMMA - Adjust GAMMA value (VIDEO,
BYPASS, 1.8, 2.0, 2.2, 2.4, 2.6, PACS).
➎ FILTER - Set the sharpness of the image (Softest,
Soft, Normal, Sharp, Sharpest).
➏ OVER SCAN - Adjust the displayed size ( 0~8)
❼ IMAGE SETTING - Change the image setting
(PRESET 1, PRESET 2, USER 1, USER 2, USER 3).
❽ ZOOM / PAN - Enlarge the image.
➒ FREEZE FRAME - Freezes the image.
will disappear after adjusting the duration
(5, 10, 20, 30, 60, 90, 120, 180, 240 seconds).
❹ RESET SETTINGS - Changes all the OSD values
to factory out-going status.
➎ AUTO SOURCE SELECT - Disable or enable
auto source select. (ON: Searches through all
possible input sources until an active video source
is found. OFF: Video input is manually selected.)
➏ USER NAME ENTRY - Change the name of a
Preset to the Users Name, etc.
E
PIP Menu
❶ LAYOUT - Changes the OSD layout (Single, PIP,
PBP1, PBP2).
For each LAYOUT selection, the following Sub-menus
are available:
❷ SOURCE - Changes the secondary source.
❸ SIZE - Changes the PIP size (Small, Large).
❹ POSITION - Changes the PIP location.
➎ SWAP - Swaps the position and size of the Primary
and Secondary image.
E-17
E
1.9.4SVIDEO / CVIDEO Input Source
Adjust Menu
❶ BRIGHTNESS - Increase or decrease the
brightness (Range: 0~100).
❷ CONTRAST - Increase or decrease the contrast
(Range: 0~100).
❸ SHARPNESS - Adjust the sharpness of the video
image (Range: 0~100).
❹ SATURATION - Changes the tone of the color
(Range: 0~100).
➎ COLOR - Changes the richness of the color
(Range: Green 0~50, Red 0~50).
➏ BACK LIGHT - Increase or decrease the back
light dimming level (Range: 0~100).
Color Temp Menu
❶ MODE - Change the color temperature mode:
6500K, 5600K, USER. When USER is selected, a
sub-menu displays allowing the user to adjust the
RED, GREEN or BLUE balance.
❷ RED - Red balance- Only works with USER mode
(Range: 0~100).
❸ GREEN - Green balance- Only works with USER
mode (Range: 0~100).
❹ BLUE - Blue balance- Only works with USER
mode (Range: 0~100).
E-18
Image Menu
❶ IMAGE SIZE - Change the image size
(Scaling mode) (Full; Fill Aspect; 1:1; Normal;
Anamorphic).
❷ H POSITION - Adjust the horizontal (left or right)
position of the displayed source image
(Range: 0~100).
❸ V POSITION - Adjust the vertical (up or down)
position of the displayed source image
(Range: 0~100).
❹ GAMMA - Adjust GAMMA value (VIDEO,
BYPASS, 1.8, 2.0, 2.2, 2.4, 2.6, PACS).
➎ FILTER - Set the sharpness of the image (Softest,
Soft, Normal, Sharp, Sharpest).
➏ OVER SCAN - Adjust the displayed size ( 0~8)
❼ IMAGE SETTING - Change the image setting
(PRESET 1, PRESET 2, USER 1, USER 2, USER 3).
❽ ZOOM / PAN - Enlarge the image.
➒ FREEZE FRAME - Freezes the image.
will disappear after adjusting the duration
(5, 10, 20, 30, 60, 90, 120, 180, 240 seconds).
❹ RESET SETTINGS - Changes all the OSD values
to factory out-going status.
➎ AUTO SOURCE SELECT - Disable or enable
auto source select. (ON: Searches through all
possible input sources until an active video source
is found. OFF: Video input is manually selected.)
➏ USER NAME ENTRY - Change the name of a
Preset to the Users Name, etc.
PIP Menu
❶ LAYOUT - Changes the OSD layout (Single, PIP,
PBP1, PBP2).
For each LAYOUT selection, the following Sub-menus
are available:
❷ SOURCE - Changes the secondary source.
❸ SIZE - Changes the PIP size (Small, Large).
❹ POSITION - Changes the PIP location.
➎ SWAP - Swaps the position and size of the Primary
and Secondary image.
E-20
1.9.5SDI Input Source
Adjust Menu
❶ BRIGHTNESS - Increase or decrease the
brightness (Range: 0~100).
❷ CONTRAST - Increase or decrease the contrast
(Range: 0~100).
❸ SATURATION - Changes the tone of the color
(Range: 0~100).
❹ COLOR - Changes the richness of the color
(Range: Green 0~50, Red 0~50).
➎ BACK LIGHT - Increase or decrease the back
light dimming level (Range: 0~100).
E
Color Temp Menu
❶ MODE - Change the color temperature mode:
6500K, 5600K, USER. When USER is selected, a
sub-menu displays allowing the user to adjust the
RED, GREEN or BLUE balance.
❷ RED - Red balance- Only works with USER mode
(Range: 0~100).
❸ GREEN - Green balance- Only works with USER
mode (Range: 0~100).
❹ BLUE - Blue balance- Only works with USER
mode (Range: 0~100).
E-21
Image Menu
E
❶ IMAGE SIZE - Change the image size
(Scaling mode) (Full; Fill Aspect; 1:1; Normal,
Anamorphic).
❷ GAMMA - Adjust GAMMA value (VIDEO,
BYPASS, 1.8, 2.0, 2.2, 2.4, 2.6, PACS).
❸ FILTER - Set the sharpness of the image (Softest,
Soft, Normal, Sharp, Sharpest).
❹ OVER SCAN - Adjust the displayed size ( 0~8)
➎ IMAGE SETTING - Change the image setting
(PRESET 1, PRESET 2, USER 1, USER 2,
USER 3).
➏ ZOOM / PAN - Enlarge the image.
❼ FREEZE FRAME - Freezes the image.
will disappear after adjusting the duration
(5, 10, 20, 30, 60, 90, 120, 180, 240 seconds).
❹ RESET SETTINGS - Changes all the OSD values
to factory out-going status.
➎ AUTO SOURCE SELECT - Disable or enable
auto source select. (ON: Searches through all
possible input sources until an active video source
is found. OFF: Video input is manually selected.)
➏ USER NAME ENTRY - Change the name of a
Preset to the Users Name, etc.
E-22
PIP Menu
❶ LAYOUT - Changes the OSD layout (Single, PIP,
PBP1, PBP2).
For each LAYOUT selection, the following Sub-menus
are available:
❷ SOURCE - Changes the secondary source.
❸ SIZE - Changes the PIP size (Small, Large).
❹ POSITION - Changes the PIP location.
➎ SWAP - Swaps the position and size of the Primary
and Secondary image.
E
E-23
E
1.10 OSD System Overview
MENUSFUNCTION DESCRIPTION
BRIGHTNESSAdjust the image brightness.
Setting the brightness too high will cause the image to bloom or flare, too
low will decrease the visible light
CONTRASTAdjust the image contrast.
Setting the Contrast too high or too low will causes loss of some greyscales.
PHASEAdjust the phase level.
Do not adjust manually - fine adjustment will occur automat ically dur ing
auto adjustment. When the phase value is wrong, the image may have
interference from “noise”.
CLOCKAdjust the sampling frequency.
Do not adjust manually - fine adjustment will occur automat ically dur ing
auto adjustment. When the frequency value is wrong, the horizontal image
may be the wrong size or have interference from “noise”.
BACKLIGHTAdjust the backlight dimming level. Setting the backlight too low will
cause a dark image and too high will decrease the backlight lifetime.
AUTO ADJUSTFit to the most appropriate screen on the D-SUB Analog signal.
SHARPNESSAdjusts the sharpness of the video image
SATURATIONChanges the tone of the color
COLORChange the tone richness of the color
COLOR TEMP
6500K
COLOR TEMP
5600K
COLOR TEMP USERDefault 6500K color setting. When USER is selected, Red, Green and
Default 6500K color setting
Default 5600K color setting
Blue values are changeable by the user.
H POSITIONAdjusts the Horizo ntal (left / rig ht) posi tion of the im age. I t will r eturn to
the default state when executing AUTO ADJUST OR RESET SETTINGS
E-24
V POSITIONAdjusts the Vertical (up / down) position of the image. It will return to the
FULLFILL ASPECT
1:1NORMAL
NOTE: FILL ASPECT,
YPbPr / RGBS / SDI / CVIDEO / SVIDEO input source
FULL
NORMAL size are dependent
on input size ratio.
1:1FILL ASPECT
NORMALANAMORPHIC
NOTE: FILL ASPECT,
NORMAL, ANAMORPHIC
size are dependent on input
size ratio.
1.82.02.22.42.6PACSVIDEO
default state when executing AUTO ADJUST OR RESET SETTINGS
IMAGE SIZEDSUB/ DVI OPTICAL / DVI DIGITAL input source
E
GAMMAAdjusts the gamma curve of the video image
E-25
E
0:1:2:
3:4:5:
6:7:8:
FILTERAdjusts the sharpness of the video image
OVER SCANEnable 10% over scan of the original input image
IMAGE SETTINGAllows the selection of one of five user defined image presets
FREEZE FRAMEFreezes the main image. Does not support secondary image freeze at PIP mode
LANGUAGEChanges the OSD language (8 languages). ENGLISH / GERMAN /
FRENCH / SPANISH / ITALIAN / JAPANESE / CHINESE / KOREAN
OSD POSITIONAdjusts the position of the OSD
OSD DURATIONAdjusts the time until the OSD Menu will disappear after adjusting the menu.
E-26
Loading...
+ 256 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.