Danby AAC060EB1G User Manual

Owner’s Use and Care Guide
Guide de soin d’utiliser-et
Model • Modèle
AAC060EB1G
Danby Products Ltd, PO Box 1778, Guelph, Ontario Canada N1H 6Z9
Danby Products Inc, PO Box 669, Findlay, Ohio USA 45839-0669
V1.10.12.DM
CAUTION: Read and follow all safety rules and operating instructions before first use of this product.
MISE EN GARDE : Veuillez lire attentivement les consignes de sécurité et les directives d'utilisation avant l'utilisation initiale de ce produit.
KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE: If the unit changes
ownership, be sure this manual accompanies the unit.
CONSERVER CES INSTRUCTIONS POUR CONSULTATION ULTÉRIEURE: En cas
de revente du l’unité, ce manuel doit être inclus avec l’appareil.
AIR CONDITIONER • CLIMATISEUR
Contents
CAUTION:
PRECAUTION:
Read and follow all safety rules and operat­ing instructions before first use of this prod­uct.
Veuillez lire attentivement les consignes de sécurité et les instructions d’utilisation avant l’utilisation initiale de ce produit.
CLIMATISEUR
Guide d'utilisation et d'entretien ........................
• Bienvenue
• Consignes de Sécurité Importantes
• Caractéristiques
• Installation
• Consignes d’utilisation
• Soins et Entretien
• Dépannage
• Garantie
2-17
AIR CONDITIONER
Owner’s Use and Care Guide .............................
• Welcome
• Important Safety Information
• Features
• Installation
• Operation Instructions
• Care and Maintenance
• Troubleshooting
• Warranty
Model • Modèle AAC060EB1G
18-33
Welcome
Thank you for choosing a Arcticaire appliance to provide you and your family with all of the “Home Comfort” require­ments of your home, cottage, or office. This Owner’s Use and Care Guide will provide you with valuable information necessary for the proper care and maintenance of your new appliance. If properly maintained, your Arcticaire appliance will give you many years of trouble free operation. Please take a few moments to read the instructions thoroughly and familiarize yourself with all of the operational aspects of this appliance.
For easy reference, may we suggest you attach a copy of your sales slip/receipt to this page, along with the following information, located on the manufacturers nameplate on side of the unit. This information will be necessary if your unit requires servicing and/or for general inquiries. To contact a Customer Service Representative, call TOLL FREE:
1-800-263-2629
NOTE: THIS UNIT IS NOT DESIGNED FOR “THROUGH-THE-WALL” INSTALLATION.
Model Number:
Serial Number:
Date of Purchase:
2
WARNING
Improper connection of the grounding plug can result in risk of Fire, Electric Shock and/or injury to Persons associated with the appliance. Check with a qualified service representative if in doubt that the appliance is proplery grounded.
Important Safety Information
READ AND FOLLOW ALL SAFETY INSTRUCTIONS
ELECTRICAL SPECIFICATIONS
FOR YOUR SAFETY: Read these instructions carefully before operating the unit.
1) All wiring must comply with local and national electrical codes and must
be installed by a qualified electrician. If you have any questions regarding the following instructions, contact a qualified electrician.
2) Check available power supply and resolve any wiring problems
BEFORE installing and operating this unit.
3) This 115V air conditioner uses 5.4 or less nameplate amps and may
be used in any properly wired, general purpose household receptacle. See Table 1 for specifications for individual branch circuit.
4) For your safety and protection, this unit is grounded through the power
cord plug when plugged into a matching wall outlet. If you are not sure whether your wall outlet is properly grounded, please consult a qualified electrician.
5) The wall outlet must match the 3-prong plug on the service cord supplied with the unit. DO NOT use plug adapters. See Table 2 for receptacle and fuse information. If it is necessary to use an extension cord to connect your air conditioner, use an approved “air conditioner” extension cord only (available at most local hardware stores).
6) The rating plate on the unit contains electrical and other technical data. The rating plate is located on the right side of the unit, above the power cord.
3
TABLE 1
Suggested Individual Branch Circuit
Nameplate Amps *AWG Wire Size
5.4 18
AWG- American Wire Gauge
*Based on copper wire at 60°C temperature rating.
TABLE 2
Receptacle and Fuse Types Rated Volts 125
Amps 15 Wall Outlet
Fuse Size 15 Time Delay Fuse Plug Type
(or Circuit Breaker)
Important Safety Information
READ AND FOLLOW ALL SAFETY INSTRUCTIONS
ENERGY SAVING TIPS
FOR YOUR SAFETY: Read these instructions carefully before operating the unit.
Your Danby appliance is designed to be highly efficient in energy savings. Follow these recommendations for greater efficiency.
1) Select a thermostat setting that suits your comfort needs and leave at
that chosen setting.
2) The air filter is very efficient in removing airborne particles. Keep the air
filter clean at all times. (usually cleaned every 2 weeks depending on indoor air quality).
3) Use drapes, curtains or shades to keep direct sunlight from penetrating
and heating the room, but do not allow drapes or curtains to obstruct the air flow around the unit.
4) Start your air conditioner before the outdoor air becomes hot and
uncomfortable, to avoid an initial period of discomfort while the unit is cooling off the room.
5) When outdoor temperatures are cool enough, use HIGH or LOW FAN
only. This circulates indoor air, providing some cooling comfort, and utilizes less electricity than when operating on a cooling setting.
4
Features
Air FIlter
Exterior Air Inlet
Cabinet
Interior Air Inlet
Control Panel
Interior Air Outlet
Installation Instructions
CAUTION
Because the compressor is located on the controls side of the unit (left side), this side will be heavier and more awkward to manipu­late. Inadequate support on control side of the unit can result in personal injury and damage to your unit and property. Therefore, it is recommended that you have someone assist you during the installation of this unit.
TOOLS NEEDED FOR INSTALLATION:
Screw Drivers: Phillips and flat head.
Power Drill: 1/8” (3.2mm) diameter drill bit.
Pencil
Measuring Tape
Scissors
Carpenters Level
NOTE: Save the shipping carton and packing materials for future storage or transportation. From carton, remove the plastic bag containing the installation hardware kit necessary for the installation of your air conditioner. Please check the contents of hardware kit against the corre­sponding model check list, prior to installation of the unit. See Fig. 1.
ELECTRIC SHOCK HAZARD
To avoid the possibility of personal injury, disconnect power to the unit before installing or servicing.
NOTE: Your Room Air Conditioner is designed for easy installtion in a single or double-hung window. This unit is NOT designed for vertical (slider type) windows and/or through-the-wall applications.
Installation Instructions
Fig. 1
INSTALLATION HARDWARE
LOCATION
A) This room air conditioner is designed to fit easily into a single or double
hung window. However, since window designs vary, it may be necessary to make some modifications for safe, proper installation.
B) Make sure window and frame are structurally sound and free from dry
and rotted wood.
C) For maximum efficiency, install the air conditioner on a side of the
house or building which favours more shade than sunlight. If the unit is in direct sunlight, it is advisable to provide an awning over the unit.
D) Provide sufficient clearance around the cabinet to allow for ample air
circulation through the unit (See Fig. 2). The rear of the unit should be outdoors and not in a garage nor inside a building. Keep unit as far away as possible from obstacles/obstructions and at least 30” above the floor or ground. Curtains and other objects within a room should be prevented from blocking the air flow.
E) Be certain the proper electrical outlet is within reach of the installation.
Use only a single outlet circuit rated at 15 amps. All wiring should be in accordance with local and national electrical codes.
F) DO NOT install unit where leakage of combustible gas is suspected.
Your air conditioner may fail to operate in air containing oils (including machine oils), sulfide gas, near hot springs, etc.
NOTE: Your unit is designed to evaporate condensation under normal conditions. However, under extreme humidity conditions, excess conden­sation may cause basepan to overflow to the outside. The unit should be installed where condensation run-off cannot drip on pedestrains or neigh­boring properties.
5
3/4in. (19.1mm) screws (7)
Safety Lock (1)
3/8in. (9.5mm) screws (4) *Factory installed
on some models
“L” Shaped mounting bracket (1)
* Factory installed
on some models
Sash bracket (2)
Adhesive Foam Seal(1)
Side Curtain LH (1)
Side Curtain RH (1)
LOCATION
Installation Instructions
Awning
Fence, wall, or other obstacle
Ground
Side Obstruction
20” Min
30” Min
20” Min
12” Min
Fig. 2
1) Assembly of the Upper Channel to Cabinet.
(Factory installed on some units)
• “L” Shaped Top Channel: Install the “L” shaped channel to the top of the
cabinet as shown in Fig. 3, using four (4) 3/8” screws.
2) Assembly of the Side Curtains to Cabinet.
• Extend the shutter from the shutter frame and slide it into the shutter tabs
on the side channel of the air conditioner, as shown in Fig. 4.
• Slide the shutters into the top (“L” Shaped) and bottom (“U” Shaped) channels. The shutters are identified (on frame) as left and right.
3) Completing the Installation
• Cut the foam (non adhesive) sealing strip to fit the area of the window sill
that the air conditioner will rest on.
3/8” screws
“L” shaped mounting bracket
“U” shaped Channel (Factory Installed)
Slide down into tabs
Shutter tabs
Shutter
Shutter frame
Fig. 3
Fig. 4
6
7
Installation Instructions
3) Completing the Installation (cont’d)
• Carefully place the air conditioner into the window with the “L” shaped mounting bracket (on top) positioned in front of the upper window sash. The bottom of the cabinet should be positioned on the “recessed” portion of the window frame. Pull the window down until it rests just behind the front flange of the (top) “L” shaped mounting bracket (See Fig. 5).
• Expand the shutter frames (fully) on each side and secure the top of the frames to the window sash using one 3/4” screw on each side and one in the “L” shaped mounting bracket (Fig. 5).
• Secure the shutter clamp on each side of the (lower) shutter and secure
to window sill using one 3/4” screw on each side (Fig. 5).
• Place the second foam sealing strip to fit the opening between the inside and outside windows, then attach the safety lock to the outside window frame using one 3/4” screw (See Fig. 6).
PLEASE NOTE: Window applications come in a variety of different styles. Therefore, it may be necessary to modify or improvise your particular installation.
Window sash
“L” Shaped Mounting Bracket
Shutter clamps
3/4” screws
Fig. 5
Safety Lock
3/4” screw
Foam Seal
Fig. 6
Operating Instructions
KEY PAD FEATURES
8
LED DISPLAY: Displays the following information independently;Set Temperature, Ambient RoomTemperature and Auto Timer On/Off settings.
POWER: Turns unit On/Off.
MODE: Allows you to scroll through and select the desired operating
mode; Cool , Dry , Fan Only and *Auto .The selected mode will be denot­ed by the adjacent indicator light.*‘Auto’is a pre-set factory program that automatically defines the mode (Cool or Dry) and fan speed based on the set temperature.
FAN SPEED: Select from four different fan settings;Low , Medium ,
High and Auto during Cool and Fan Only mode. Please note: During ‘Dry’ mode the fan speed is automatically defined .
ENERGY SAVER: Automatically cycles the fan on and off while the
compressor is not in use.
TEMP / TIMER CONTROL: Used to increase or decrease
the Temperature setting in 1°C / °F increments, and Auto-Timer On/Off set­tings in 30min./1hr. increments. Note: This appliance allows you select the temperature scale to be displayed in either “Celsius” or Fahrenheit” according to your preference.To change the temperature scale displayed on the electronic display, press both the “Temp/Timer”adjust arrows simul­taneously to alternate between “Celsius” & “Fahrenheit”.
CHECK FILTER: The adjacent indicator light will illuminate as a
reminder to clean the air conditioner filter (see page 9) Once the filter has been cleaned and replaced, depress the Check Filter button in order to resume operation.
SLEEP MODE: When activated, the current set temperature is gradu-
ally increased over a one (1) hour period then maintained for seven (7) hours. Once the program is complete, the air conditioner will resume to its previous set temperature (before sleep mode was activated). This feature is mean to be used during the night time hours to prevent the room from getting too cold (while you sleep) and results in less compressor running time and reduced energy consumption. Sleep mode may be cancelled by depressing the Sleep Mode button while the program is running.
AUTO-TIMER: Used to initiate the Auto On/ Auto Off timer.
While the Air Conditioner is off (Auto-On):
1) Press the Auto-Timer button once and the adjacent Auto-On indicator
light will illuminate.
2) Use the Temp/Timer control cursors to select a delayed On time of
up to 24 hours.
3) Select the appropriate mode under which you want the unit to operate
(Auto-Cool-Dry-Fan Only)
4) Select the fan speed setting.
5) The time you selected will appear in the LED display.
While the Air Conditioner is on (Auto-Off):
1) Press the Auto-Timer button twice and the adjacent Auto-Off indicator
light will illuminate.
2) Use the Temp/Timer control cursors to select a delayed Off time of up
to 24 hours.
3) The time you selected will appear in the LED display. The Auto On and
Auto Off timer can operate during the same program by defining the Auto-Off parameters immediately after the Auto On parameters.The Auto-Timer may be cancelled at any time by turning the unit On/Off.
Temp / Timer
Control
Check
Filter
Mode
Selector
Energy
Saver
LED Display
Auto Timer
Sleep Mode
Fan Speed
Power Button
Operating Instructions
USING THE REMOTE CONTROL
Location of the remote controller.
• Use the remote controller within a distance of 5 meters from the appliance, pointing it towards the receiver. Reception is confirmed by a beep.
CAUTION
The air conditioner will not operate if curtains, doors or other materials block the signals from the remote controller to the indoor unit.
Prevent any liquid from falling into the remote controller. Do not expose the remote controller to direct sunlight or heat.
If the infrared signal receiver on the indoor unit is exposed to direct sunlight, the air conditioner may not function properly. Use curtains to prevent the sunlight from falling on the receiver.
If other electrical appliances react to the remote controller, either move these appliances or call the service depot.
REMOTE CONTROLLER SPECIFICATIONS
Model
Rated Voltage
Lowest Voltage of CPU Emitting Signal
Signal Receiving Range
Environment
R15A, R15B, R15C
3.0V(Button cell: CR2025)
2.0V
5m
-5°C ~ 60°C
9
5m
E
D O M
F F
O / N
O
P M
E
N
T
W O
D
P
M
TE
P
U
G N
I W S
R
E M I
T
N A
F
EEP L
S
Operating Instructions
ON/OFF button
TEMP UP button
FAN button
CLEAN AIR button (on some models)
ENERGY SAVER button
MODE button
TEMP DOWN button
TIMER button
SLEEP button
Operation starts when this button is pressed and stops when the button is pressed again.
Push this button to increase the tempera­ture setting in 1°C increments to 30°C.
Used to select the fan speed in three steps:
LOW
MED
HIGH
When this button is pressed, the ion genera­tor is energized and will help remove pollen and impurities from the air.
Press this button to activate the Energy sav­ing mode. Press it again to stop the funtion.
Each time you press this button, a mode is selected in a sequence that goes from AUTO, HEAT (cooling and heat­ing models only) COOL, DRY, FAN and back to AUTO.
Push this button to decrease the indoor temperature setting in 1°C increments to 17°C.
Push this button to activate the “Auto Start” or “Auto Stop” program from 0-12 hours (1 hour increments)
Press this button to activate the Sleep mode. This function is available on COOL, HEAT or AUTO mode only and maintain the most comfortable temperature for you.
REMOTE CONTROLLER BUTTONS
ON/OFF button
TEMP UP button
FAN button
SWING button
MODE button
TEMP DOWN button
TIMER button
SLEEP button
Operation starts when this button is pressed and stops when the button is pressed again.
Push this button to increase the tempera­ture setting in 1°C increments to 30°C.
Used to select the fan speed in three steps:
LOW
MED
HIGH
When this button is pressed, the vertical lou­vres will swing automati­cally from side to side. Press it again to deacti­vate the "SWING" fea­ture.
Each time you press the button, a mode is selected in a sequence that goes from AUTO, HEAT (cooling and heat­ing models only) COOL, DRY, FAN and back to AUTO.
Push this button to decrease the indoor temperature setting in 1°C increments to 17°C.
Push this button to activate the “Auto Start” or “Auto Stop” program from 0-12 hours (1 hour increments)
Press this button to activate the Sleep mode. Press again to stop the function. This function is available on COOL, HEAT or AUTO mode only and maintain the most comfortable temperature for you.
Models:
R15A R15B
Models:
R15C
NOTE: Modle R15B does not have CLEAN AIR feature.
10
ON/OFF
TEMP
UP
FAN
CLEAN AIR
S
ENERGY
SAVER
MODE
TEMP DOWN
TIMER
SLEEP
ON/OFF
TEMP
UP
FAN
SWING
MODE
TEMP DOWN
TIMER
SLEEP
Loading...
+ 24 hidden pages