Door strike / Magnetic door lock page 6
Installation page 7
Setup page 8-9
Remote access/Integration page 10
Support page 11
Page 3
Product information 3/12
The Danalock Universal module is a device for controlling
all 12-24V powered commercially available locking
mechanisms; door strikes, electromechanical or
magnetic locks, gates etc.
The module works in parallel with what is already
installed or in any new installation.
The module has two relay outputs and one power
output. The relays or the power-output can be controlled
remotely with the Danalock app via Android (from
version 4.4.4) and iOS (from iOS 9.0 and iPhone 4S)
smartphones. The relay is both Bluetooth Low Energy
4.0 and/or Z-Wave driven.
Relay mode
The two relays can be operated either parallel or
separately. The relays are working for a desired time
(1-180 sec.) or permanent when activated. The activation
for the relays can be delayed for relay 2 after activating
relay 1. The two relays can be setup individually for
permanent activation or for a desired time.
Page 4
Technical specifications 4/12
Operating voltage range 12-24V DC, 12-24V AC
Max input (at 24V) 100mA
Number of relays 2
Type of relays Potential-free
contacts (NO/NC)
Max AC power 1A at 12V
Max AC current 1A at 12V
Max relay voltage 48 V
Wireless communication Bluetooth 4.0
LE/Z-Wave Plus
(optional)
Bluetooth range 5-10 meters
Page 5
Wiring diagram 5/12
Black
Power output 12-24V AC/DC 1 amp
Brown
Ground
Red
Relay 1: Normally open
Orange
Relay 1: Commen
Yel low
Relay 1: Normally closed
Green
Relay 2: Normally open
Blue
Relay 2: Commen
Violet
Relay 2: Normally closed
Grey
Power input 12-24V AC/DC 1 amp
White
Ground input 12-24V AC/DC 1 amp
Page 6
Wiring diagram -
Magnetic door lock
Black
Power output 12-24V AC/DC 1 amp
Brown
Ground
Red
Relay 1: Normally open
Orange
Relay 1: Commen
Yel low
Relay 1: Normally closed
Green
Relay 2: Normally open
Blue
Relay 2: Commen
Violet
Relay 2: Normally closed
Grey
Power input 12-24V AC/DC 1 amp
White
Ground input 12-24V AC/DC 1 amp
6/12
Grey
12/24 in
White
12/24 in
Page 7
Wiring diagram -
Door strike
7/12
Black
Power output 12-24V AC/DC 1 amp
Brown
Ground
Red
Relay 1: Normally open
Orange
Relay 1: Commen
Yel low
Relay 1: Normally closed
Green
Relay 2: Normally open
Blue
Relay 2: Commen
Violet
Relay 2: Normally closed
Grey
Power input 12-24V AC/DC 1 amp
White
Ground input 12-24V AC/DC 1 amp
Grey
12/24 in
White
12/24 in
Page 8
Installation 8/12
1. Mounting instruction
Connect the Universal Module to the relevant motor drive
while considering the wiring diagram.
Note!
Please make sure to connect the Universal Module to a
smartphone during installation. As soon as you are registered
as owner, no one else is able to control the door/gate, and it
is only you who can grant other users access.
2. Connect to the smartphone
To connect the Module to a smartphone, please follow the
Danalock App User Guide on:
https://danalock.com/?page_id=2894
When installing the Module you will be asked to set the Relay
time. In the User guide for the motorized door lock you will
find the recommended time (pulse = 1sec). Per default, the
Universal Module will switch off after 1 sec.
Note!
The Relay time can be changed under settings at any time.
Page 9
User Guide 9/12
You find the updated version of the Danalock App User
Guide under:
https://danalock.com/?page_id=2894
Among other things, the guide will show you how to share
access. If you like to change owner/administrator of the
Module, you have to delete the Module from the app before
connecting it to a new owner.
Note!
Please only delete the Module from the keychain when in
Bluetooth range of the Module. If you are not in Bluetooth
range, you will have to reset (see “Touch button commands)
it by pressing the button on the Module. If the Module is a
built-in solution, a reset can cause additional charges from
eg. a locksmith.
Page 10
Touch button commands 10/12
You find the gold-colored touch button in one corner
of the circuit board. One short press switches the
Relay off. Holding down/pressing the touch button
will trigger the following commands:
1 flash switches the relays off.
2 flashes puts the Module in
Z-Wave inclusion mode.
5 flashes resets the key.
10 flashes means a factory reset
of all key and relay settings.
Page 11
Remote access/Integration 11/12
Danabridge
The Universal Module is only accessible when the
user is in Bluetooth range. To gain remote access,
you can use a spare smartphone or tablet:
https://danalock.com/?page_id=2981
Z-Wave
The Danalock Universal Module with Z-Wave is
compatible with a long list of gateways.
Read more about it here:
https://danalock.com/?page_id=2597
Page 12
Support 12/12
You will find a list with frequently asked questions here:
https://danalock.com/?page_id=3417
Please write or call us in case of any questions:
support@danalock.com
+0045 42428122
Gammel Stillingvej 427 C, 8462 Harlev - DK
Poly-control ApS
mail@danalock.com
support@danalock.com
+45 4242 8122
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.