VEEDER-ROOT brand
Proximity and Precision Switches
General Purpose, AC-Powered
Just two wires – connects
like a conventional switch
. . . delivers repeatable,
wear-free operation
Detects the presence of ferrous and nonferrous metals and produces a
control output to switch AC circuits. Completely self-contained, they
provide a long-life, noncontact, alternative to mechanical limit-switches
in many machine control and object sensing applications. Threaded
tubular housing for easy mounting to machine structures or brackets.
Shielded
face-circumference, therefore can be flush-mounted in a metal surface.
Unshielded
housing, gaining about 50% extra sensing distance over equivalent
shielded units, but can not be flush-mounted in metal. Several models
feature an LED indicator that confirms proper alignment and operation.
■ Quality construction and materials – NEMA-4/IP67 rated
■ Replaces mechanical switches – does the job without contact or wear
■ Noncontact sensing – does not touch detected object
■ Operation at -13° to +167°F (-25° to +75°C) temperature range
■ Suited for solid-state as well as conventional loads
■ Wide operating voltage and power frequency range
■ Can directly switch moderate loads, such as AC relays or solenoids
■ Available diameters: 12 mm, 18 mm, 30 mm; shielded and
■ LED indicator confirms proper target alignment
Using just two wires, they simply connect in series with the AC load to
be controlled – relay, light, valve, solenoid, etc. Many high impedance
loads, such as PLC AC-input modules, solid-state relays, and electronic
counters can be switched, generally not requiring an external load
resistor.
types are not influenced by metallic material surrounding their
types have a sensing face that extends beyond their metal
unshielded
For limit switch housing, see Series 6600
SPECIFICATIONS
Electrical Characteristics:
Operating Voltage Range: 90-250 (±10%) VAC, 50/60 Hz
Configuration: Normally Open
Load Current:
Maximum Continuous at 50°C (linearly derated above 50°C):
12mm Types: 150mA; 18mm & 30mm Types: 200mA
Minimum Continuous: 5mA
Leakage Current: <1.5mA @ 110V; <3.0mA @ 220V
On-State Voltage Drop: <8V
Operating Characteristics (all devices):
Sensing Distance Tolerance: ±10%
Min./Max. Hysteresis (% of nom.): 3/20
` Operating Temperature: -13° to +167°F (-25° to +75°C)
Switching Frequency: 10 Hz Max.
Enclosure Material: Nickel plated brass
Enclosure Ratings: NEMA-4, -13 (IP67)
Termination Type: 2-conductor, 2-meter cable
Sens.
Model Number
0651210-700 Yes Yes 2.0 5 mA 150 mA 12 mm 60 mm 2M
0651210-701 Yes No 4.0 5 mA 150 mA 12 mm 64 mm 2M
0651810-600 Yes Yes 5.0 5 mA 200 mA 18 mm 65 mm 2M
0651810-601 Yes No 8.0 5 mA 200 mA 18 mm 73 mm 2M
0653010-700 Yes Yes 10.0 5 mA 200 mA 30 mm 60 mm 2M
0653010-701 Yes No 15.0 5 mA 200 mA 30 mm 70 mm 2M
LED Shld.
2-Wire AC, Normally Open, 90 to 250 VAC Operation
Dist.
(mm)
Load Current
Minimum Maximum
Dimensions
D L C
T
O
T
A
L
Z
N
G
11
P
R
O
X
I
M
I
I
T
Y
I
A
N
D
P
R
E
C
I
S
I
O
N
S
W
I
T
C
H
E
S
For typical applications, see Proximity Switch
Introduction and Selection Guide, pages 11.00-11.03
Dimensions:
C
See ordering table for dimensions.
L
D
DANAHER INDUSTRIAL CONTROLS
11.05