INSTALLATION AND OPERATING INSTRUCTIONS FOR
Single Motor Low Voltage
Control System

Important Safety Instructions
When using your video equipment, basic safety precautions should always be followed, including the following:
1. Read and understand all instructions before using.
2. Position the cord so that it will not be tripped over, pulled, or
contact hot surfaces.
3. If an extension cord is necessary, a cord with a current rating at
least equal to that of the appliance should be used. Cords rated
for less amperage than the appliance may overheat.
4. To reduce the risk of electric shock, do not disassemble this
appliance. Contact an authorized service dealer when repair
work is required. Incorrect reassembly can cause electric shock
when the appliance is used subsequently.
5. The use of an accessory attachment not recommended by the
manufacturer may cause a risk of ire, electric shock, or injury to
persons.
Save These Instructions
Pre-Installation
The low voltage control (LVC) housing is divided into 3 compartments. the compartment labeled “Low Voltage Connections” is where
you will connect the wall switch or a central control panel. The compartment labeled “AC Power Connections” is where the main power
and motor wire connections are made. The center compartment only requires access when connecting an infrared or radio frequency
remote receiver.
Low Voltage Connections
White
WARNING: To prevent electrical shock or damage to the
LVC, do not apply power to the LVC until all connections
are complete. Make sure power is turned of on all wires
before making connections.
Black
AVERTISSEMENT: pour éviter tout choc électrique ou
d'endommager le tableau de contrôle basse tension,
n'alimentez ce dernier qu'une fois tous les branchements
efectués. Vériiez qu'aucun câble n'est alimenté avant
d'efectuer les branchements.
Wall Switch
WARNING: This unit must be used with the enclosed switch.
DO NOT USE the rocker switch included with screen.
AVERTISSEMENT: Cette unité doit être utilisée avec
l'interrupteur fourni. NE UTILISEZ PAS l'interrupteur à
bascule fourni avec l'écran.
1. Install wall switch where desired.
2. Use 3-conductor 2024 gauge wire to extend the switch wire to
the required length.
3. Connect the wire from the switch to the wire labeled “wall switch”.
Refer to diagram 1.
CAUTION: Never apply voltage to the wall switch lead or the
LVC will be damaged.
ATTENTION: N'appliquez jamais une tension aux ils du
commutateur mural sinon le tableau de contrôle basse
tension sera endommagé.
2
Black
Recommended Wire Size:
2024 AWG
Figure 1
Red
Low-Voltage
Wall Switch
Up
Stop
Down
Control Panel
A control panel may be connected to the LVC by using the wall
switch wire lead. The control panel must provide a momentary,
dry contact closure of at least 1/2 second.
1. Use 3-conductor 2024 gauge wire to connect the control panel
to the wall switch lead.
2. A momentary closure across the white and red wires will be an
“up” command.
3. A momentary closure across the white and black wires will be a
“down” command.
4. A momentary closure across the white, red and black wires will
be a “stop” command.
CAUTION: Never apply voltage to the wall switch lead or the
LVC will be damaged.
ATTENTION: N'appliquez jamais une tension aux ils du
commutateur mural sinon le tableau de contrôle basse
tension sera endommagé.

AC Power Connections
Screen Motor
1. Connect the motor wires in the screen junction box to the
LVC wires labeled “motor wires”. Refer to diagram 2.
Green
Ground
Screen
White-White
Black-Black
Red-Red
Figure 2
120VAC 60Hz 240 VAC 50Hz
Ground Lug
Recommended Wire Size:
1418 AWG
AC Power Source
1. Connect power wires to the LVC wires labeled “AC power input”.
Refer to diagram 3.
2. Use 1418 gauge wire to extend the motor wire to the
required length.
Green/Yellow
Ground
Screen
Blue-Blue
Brown-Brown
Black-Black
Up
Stop
Down
Ground Lug
Recommended Wire Size:
1418 AWG
2. Connect the building ground wire to the ground lug on the
metal housing.
Up
Stop
Down
Power
Source
120VAC
60HZ
Green Ground
Ground Lug
Recommended Wire Size:
1418 AWG
Black Hot
White Common Blue Common
Figure 3
Optional Wireless Remote Connections:
Radio Frequency Remote
1. Remove the cover plate labeled “Low voltage connections” and
the center cover plate.
2. Route the receiver wire through the round plastic bushing and
plug it into the onboard socket marked “EYE”. Refer to diagram 4.
120VAC 60Hz 240VAC 50Hz
Optional RF Remote,
IR Remote Or Video Projector
Interface Connector
UP
STOP
DOWN
Brown
Hot
Power
Source
240VAC
50HZ
Green Ground
Ground Lug
Recommended Wire Size:
1418 AWG
Up
Stop
Down
Infrared Remote
1. Remove the cover plate labeled “Low voltage connections” and
the center cover plate.
2. Route the receiver wire through the round plastic bushing and
plug it into the onboard socket marked “EYE”. Refer to diagram 4.
Optional RF Remote,
IR Remote Or Video Projector
Interface Connector
EYE AUX
EYE AUX
Figure 4
3

Troubleshooting
Visit www.da-lite.com to ind installation and troubleshooting tutorials. You will also ind a link to Live Chat for interactive support and
you can contact us by email at info@da-lite.com or by phone at (800) 6223737 or (574) 2678101 with any troubleshooting questions.
Symptom Cause Solution
Screen will not operate.
Radio frequency remote
does not work.
Infrared remote does not work.
Screen runs in the wrong
direction.
No power to LVC unit.
Incorrect wiring.
Low voltage circuit damaged due to voltage input.
LVC controller lock-up.
Weak battery in transmitter. Replace battery.
Weak battery in transmitter. Replace battery.
Receiver incorrectly positioned.
Fluorescent light interference.
Red and black wires are reversed on motor or wall
switch terminals.
Turn on power to LVC input. Measure voltage across
black and white input leads.
Recheck all wiring for proper installation. Check all wire
nut connections.
The wall switch terminal is for dry contact (no voltage) input
only. Applying voltage to this terminal will damage the LVC.
Locate breaker for screen and turn o power.
Wait one minute and re-activate circuit.
Receiver must be unobstructed and located in direct
line with the transmitter..
Remote receiver should not be placed near
luorescent lights.
Turn o power to LVC. Reverse the red and black wires
on either the motor terminals or the wall switch terminals.
Changing either one will change the direction of motor
travel. Do not change both.
NOTE: The LVC will shut of power to the screen motor 5 minutes after the motor stops turning. Push the up or down button to
reactivate the LVC relays.
A Milestone AV Technologies Brand
3100 North Detroit Street
Warsaw, Indiana 46582
P: 574.267.8101 or 800.622.3737
F: 574.267.7804 or 877.325.4832
E: info@da-lite.com
www.da-lite.com
DL–0346 (Rev. 2) 02.15
© 2015 Milestone AV Technologies LLC. Printed in U.S.A.
98885