Da-Lite Single Motor Low Voltage Control System Users Guide

INSTALLATION AND OPERATING INSTRUCTIONS FOR
Single Motor Low Voltage
Control System
Important Safety Instructions
When using your video equipment, basic safety precautions should always be followed, including the following:
1. Read and understand all instructions before using.
2. Position the cord so that it will not be tripped over, pulled, or contact hot surfaces.
3. If an extension cord is necessary, a cord with a current rating at least equal to that of the appliance should be used. Cords rated for less amperage than the appliance may overheat.
4. To reduce the risk of electric shock, do not disassemble this appliance. Contact an authorized service dealer when repair work is required. Incorrect reassembly can cause electric shock when the appliance is used subsequently.
5. The use of an accessory attachment not recommended by the manufacturer may cause a risk of ire, electric shock, or injury to persons.
Save These Instructions
Pre-Installation
The low voltage control (LVC) housing is divided into 3 compartments. the compartment labeled “Low Voltage Connections” is where you will connect the wall switch or a central control panel. The compartment labeled “AC Power Connections” is where the main power and motor wire connections are made. The center compartment only requires access when connecting an infrared or radio frequency remote receiver.
Low Voltage Connections
White
WARNING: To prevent electrical shock or damage to the
LVC, do not apply power to the LVC until all connections
are complete. Make sure power is turned of on all wires
before making connections.
Black
AVERTISSEMENT: pour éviter tout choc électrique ou
d'endommager le tableau de contrôle basse tension,
n'alimentez ce dernier qu'une fois tous les branchements
efectués. Vériiez qu'aucun câble n'est alimenté avant
d'efectuer les branchements.
Wall Switch
WARNING: This unit must be used with the enclosed switch.
DO NOT USE the rocker switch included with screen.
AVERTISSEMENT: Cette unité doit être utilisée avec
l'interrupteur fourni. NE UTILISEZ PAS l'interrupteur à
bascule fourni avec l'écran.
1. Install wall switch where desired.
2. Use 3-conductor 2024 gauge wire to extend the switch wire to the required length.
3. Connect the wire from the switch to the wire labeled “wall switch”. Refer to diagram 1.
CAUTION: Never apply voltage to the wall switch lead or the
LVC will be damaged.
ATTENTION: N'appliquez jamais une tension aux ils du
commutateur mural sinon le tableau de contrôle basse
tension sera endommagé.
2
Black
Recommended Wire Size:
2024 AWG
Figure 1
Red
Low-Voltage
Wall Switch
Up
Stop
Down
Control Panel
A control panel may be connected to the LVC by using the wall switch wire lead. The control panel must provide a momentary, dry contact closure of at least 1/2 second.
1. Use 3-conductor 2024 gauge wire to connect the control panel to the wall switch lead.
2. A momentary closure across the white and red wires will be an “up” command.
3. A momentary closure across the white and black wires will be a “down” command.
4. A momentary closure across the white, red and black wires will be a “stop” command.
CAUTION: Never apply voltage to the wall switch lead or the
LVC will be damaged.
ATTENTION: N'appliquez jamais une tension aux ils du
commutateur mural sinon le tableau de contrôle basse
tension sera endommagé.
AC Power Connections
Screen Motor
1. Connect the motor wires in the screen junction box to the LVC wires labeled “motor wires”. Refer to diagram 2.
Green
Ground
Screen
White-White
Black-Black
Red-Red
Figure 2
120VAC 60Hz 240 VAC 50Hz
Ground Lug
Recommended Wire Size:
1418 AWG
AC Power Source
1. Connect power wires to the LVC wires labeled “AC power input”. Refer to diagram 3.
2. Use 1418 gauge wire to extend the motor wire to the required length.
Green/Yellow
Ground
Screen
Blue-Blue
Brown-Brown
Black-Black
Up
Stop
Down
Ground Lug
Recommended Wire Size:
1418 AWG
2. Connect the building ground wire to the ground lug on the metal housing.
Up
Stop
Down
Power
Source
120VAC
60HZ
Green Ground
Ground Lug
Recommended Wire Size:
1418 AWG
Black Hot
White Common Blue Common
Figure 3
Optional Wireless Remote Connections:
Radio Frequency Remote
1. Remove the cover plate labeled “Low voltage connections” and the center cover plate.
2. Route the receiver wire through the round plastic bushing and plug it into the onboard socket marked “EYE”. Refer to diagram 4.
120VAC 60Hz 240VAC 50Hz
Optional RF Remote, IR Remote Or Video Projector Interface Connector
UP
STOP
DOWN
Brown
Hot
Power
Source
240VAC
50HZ
Green Ground
Ground Lug
Recommended Wire Size:
1418 AWG
Up
Stop
Down
Infrared Remote
1. Remove the cover plate labeled “Low voltage connections” and the center cover plate.
2. Route the receiver wire through the round plastic bushing and plug it into the onboard socket marked “EYE”. Refer to diagram 4.
Optional RF Remote, IR Remote Or Video Projector Interface Connector
EYE AUX
EYE AUX
Figure 4
3
Troubleshooting
Visit www.da-lite.com to ind installation and troubleshooting tutorials. You will also ind a link to Live Chat for interactive support and you can contact us by email at info@da-lite.com or by phone at (800) 6223737 or (574) 2678101 with any troubleshooting questions.
Symptom Cause Solution
Screen will not operate.
Radio frequency remote does not work.
Infrared remote does not work.
Screen runs in the wrong direction.
No power to LVC unit.
Incorrect wiring.
Low voltage circuit damaged due to voltage input.
LVC controller lock-up.
Weak battery in transmitter. Replace battery.
Weak battery in transmitter. Replace battery.
Receiver incorrectly positioned.
Fluorescent light interference.
Red and black wires are reversed on motor or wall switch terminals.
Turn on power to LVC input. Measure voltage across black and white input leads.
Recheck all wiring for proper installation. Check all wire nut connections.
The wall switch terminal is for dry contact (no voltage) input only. Applying voltage to this terminal will damage the LVC.
Locate breaker for screen and turn o power. Wait one minute and re-activate circuit.
Receiver must be unobstructed and located in direct line with the transmitter..
Remote receiver should not be placed near luorescent lights.
Turn o power to LVC. Reverse the red and black wires on either the motor terminals or the wall switch terminals. Changing either one will change the direction of motor travel. Do not change both.
NOTE: The LVC will shut of power to the screen motor 5 minutes after the motor stops turning. Push the up or down button to reactivate the LVC relays.
A Milestone AV Technologies Brand
3100 North Detroit Street Warsaw, Indiana 46582 P: 574.267.8101 or 800.622.3737 F: 574.267.7804 or 877.325.4832 E: info@da-lite.com www.da-lite.com
DL–0346 (Rev. 2) 02.15 © 2015 Milestone AV Technologies LLC. Printed in U.S.A.
98885