Daiwa DWA-9150 Operating Lnstructions

GARDENA, CA 90249
DWA -9150
DWA-9150 LEGACY 3D MASSAGE LOUNGER
Online warranty resgistration at : http://www.usjaclean.com/pages/warranty-registration
Operating Instructions
IMPORTANT SAFETY PRECAUTIONS
Basic precautions should always be followed when using an electrical unit, including the following. Please ensure that you read all instructions before using the Legacy 3D.
– To reduce the risk of electric shock:
1. Always insert the power plug all the way into the outlet to reduce the risk of short-circuit and fire.
2. The unit should never be left unattended when plugged in. Always unplug the unit when not in use.
3. The unit is not to be used by people who cannot move or communicate on their own.
4. Only use the unit for the purpose described in these instructions.
5. Do not stand on the unit.
6. Always return the seat to the upright position and make sure the legrest is completely retracted. Be careful that nothing is obstructing the legrest while retracting. Keep children away from the legrest.
7. Never operate the unit if it has a damaged power cord or plug. Return the unit to the nearest authorized service center if it is not working properly, if it has been dropped or damaged, or if it has been immersed in water.
8. Keep power cords away from heated surfaces. Do not carry the unit by the power cord.
9. Never block the air openings during operation and make sure that all air openings are kept free of lint and hair, etc. Do not drop or insert anything into any of the openings of the unit.
10. Do not use the unit on top of heating appliances, such as electric carpets, etc. Do not operate the unit under a blanket or pillow. Excessive heating can occur and cause fire, electric shock, or injury to persons.
11. Do not use the unit in bathrooms or other damp or humid places as this may cause electric shock or cause the unit to malfunction. Do not spill water, etc. onto the controller.
12. Do not use the unit outdoors.
13. Do not use or operate where aerosol spray products are being used or where oxygen is being administered.
14. When unplugging the unit, turn off all controls before removing the plug from power outlet. Do not use the unit with a transformer as this may lead to malfunction or electric shock.
15. Connect this unit to a properly grounded outlet only. See Grounding Instructions.
16. Use heated surfaces carefully. May cause serious burns. Do not use over insensitive skin areas or in the presence of poor circulation. The unattended use of heat by children or incapacitated persons may be dangerous.
DANGER
WARNING
– To reduce the risk of burns, fire, electric shock, or injury to persons:
1. Always unplug this unit from the electrical outlet immediately after using and before cleaning.
1
IMPORTANT SAFETY PRECAUTIONS
1. Persons with any of the conditions listed below or who are undergoing medical treatment or suffer from medical conditions should consult with their physicians before using the unit:
a) Pregnant women, people who are ill, in poor physical shape.
b) People suffering from back, neck, shoulder, or hip pain.
c) People who have a pacemaker, defibrillator, or other personal medical devices prone to electronic interference.
d) People suffering from heart disease.
e) People who are prohibited from receiving massage by a physician due to thrombosis or aneurism, acute varicose veins, or other circulatory disorders.
f) People with irregular curvatures of the spine.
g) People who have a loss of heat sensation.
2. This unit should not be used by children.
3. Sit down slowly after checking the position of the massage heads. Never put any part of your body between the massage heads as the squeezing action of the massage heads may cause injury. Never put your fingers or feet in the gap between the backrest and seat, the backrest and the armrest, the seat and cover under the armrest, or the gap between the legrest and the footrest. Do not place your fingers or any part of your body in the mechanism below the legrest, or between the legrest and footrest.
4. Do not use the unit against bare skin. While thin clothing may increase effectiveness, exposing the skin directly to the massager may irritate the skin. Do not use the unit while wearing anything hard on your head like a hair accessory, etc. Do not use the unit for massaging the head, abdomen, front neck, elbows or knees. Do not use excessively strong massage action on the back of the neck.
5. When using the body scanning function, always ensure that the shoulder position is correct. If the shoulder position is not correct, use the POSITION button to adjust it properly, or stop the massage function and re-try the body scanning function. You can adjust the shoulder position in this way in the auto program and manual operation. Failure to align the shoulder position correctly can lead to injury.
6. While using the massager, if the pressure seems too strong, the movement of the massage heads can be stopped at any time by pressing the Stop button.
7. Do not go to sleep while using the massage function.
8. Do not use the unit after drinking alcohol.
9. When the seat back is in a reclined position, do not sit on it or sit with your legs resting on the headrest. Do not sit on the legrest as the unit may fall over.
10. Do not allow children or pets to play on or around the unit, especially during operation.
11. Do not unplug the unit or turn it off during operation. Unplug the unit immediately if there is a power outage.
12. Do not allow children to play on this mechanized furniture or operate the mechanism. Legrest folds down on closing so that a child could possibly be injured.
13. Always leave in an upright and closed position.
14. Keep hands and feet clear of mechanism. Only the occupant should operate it.
15. Remove hard objects, such as false fingernails, wristwatches or rings, when massaging hands or arms. Empty pockets of hard objects when massaging the area of the seat or thighs.
16. When “Heat” massage heads are used, do not let the massage heads touch the same place for a long time.Low-temperature burn may occur.
2
Headrest
Backrest
Speakers
Armrest
Seat cushion
Footrest
Back Cover
Caster
3D Massage mechanism Shoulder airbags
Arm airbags
Back heater
Seat airbags
Seat heater
Leg airbags
Foot airbags
Foot rollers
PARTS
EXTERIOR PARTS
INTERIOR PARTS
3
Controller port
Power supply socket
Safety fuse
Power on/off
POWER SUPPLY BOX
PARTS
4
On/Off
Up
Left
Down
Footrest up
Footrest down
Leg extend
Shoulder adjustment
Auto mode
Right
Backrest up
Backrest down
Leg retract
Menu
Display screen
OK
3D massage
OPERATION
MAIN CONTROLLER
5
OPERATION
Power Button
Press to turn on the unit. The display screen will light up.
Press the Up or Down key to highlight your preferred massage mode and
preference. Press the center OK key to select.
Press again to turn off all functions. The default running time is 15 minutes
for each massage.
CONTROLLER OPERATION
Menu Button
During any massage operation, press here to:
1. Select and switch to a direct massage function
2. Add or end an option to run with your current massage program
Shoulder Position Adjustment keys
While the Point mode manual program in running, use these keys to
adjust your desired position of the point massage.
Auto mode button
Press this button to bring up the chair’s six automatic massage programs.
Direction Dial
After pressing the Menu or Auto mode buttons, use the Up, Down,
Left, or Right direction keys to move among selections. Then press
the center OK key to confirm that selection
During the massage, press the Up, Down direction keys to adjust the
massage speed. Press the Left, Right direction keys to adjust the
airbag force.
Footrest Up Button
Press and hold to raise the leg rest. Release the button when it reaches your
desired position.
3D Button
Press to adjust the 3D massage mechanism.
Footrest Down Button
Press and hold to lower the leg rest. Release the button when it reaches your
desired position.
6
Backrest Up Button
Press and hold to raise the backrest. Release the button when it reaches
your desired position.
Backrest Down Button
Press and hold to lower the backrest. Release the button when it reaches
your desired position.
Leg Extend Button
Press and hold to extend the footrest. Release the button when it reaches
your desired position.
Leg Retract Button
Press and hold to retract the footrest. Release the button when it reaches
your desired position.
Automatic Programs
Press followed by to bring up the Automatic Programs menu.
Use the Up or Down keys to highlight one of six automatic massage programs:
RECOVERY (Warm up)
EXTEND (Stretch)
RELAX (Cool down)
REFRESH (Light massage)
UPPER BODY AUTO (Focused massage on the upper body)
LOWER BODY AUTO (Focused massage on the lower body)
Press to select.
OPERATION
DISPLAY SCREEN OPERATION
7
OPERATION
MODE
Under the Mode function, press Up or Down arrow keys to choose between Kneading, Tapping, Knocking, Shiatsu, Sync or Rhythm.
KNEADING
Select Kneading and press the OK button. Press the Up or Down keys to choose between Kneading Up or Kneading Down.
PART
Under the Part function, press the Right arrow key first, then press the Up or Down arrow keys to highlight the specific part of the body you wish to massage.
WIDTH
Under the Width function, press the Right arrow key first, then press the Up or Down arrow keys to highlight your desired width of the massage rollers.
SPEED
Under the Speed function, press the Right arrow key first, then press the Up or Down arrow keys to choose your desired massage roller speed.
8
Manual Programs
Press (Menu button) and scroll down to the Manual option.
Press the OK button to select.
Press Up or Down arrow keys to choose your desired massage mode.
Press the Right arrow key to select and move on to the next menu.
Loading...
+ 9 hidden pages