DAITEM SH402AX Installation Manual

92
GB
Contents
1. Introduction ........................................ 93
2. Preparing the siren ............................ 94
2.1 Tooling required .............................. 94
2.2 Opening the siren and connecting
3. Recognition programming................ 94
4. Setting the parameters ..................... 96
4.1 Delayed alarm sounding
upon intrusion................................. 97
4.2 Duration of sounding...................... 97
4.3 Sound level of arm and disarm
command indications..................... 97
4.4 Transfer of arm and disarm
command indications..................... 97
4.5 Indication of audible signals
and door bell................................... 98
4.7 Modification of speech synthesis
system language ............................ 98
4.8 Triggering upon intrusion
4.9 Protection system armed
indication ........................................ 99
4.10 Alarm in armed presence mode
indication ...................................... 99
4.11 Triggering by a technical alarm.... 99
4.12 Triggering following a communication network
interruption.................................... 99
4.13 Radio tamper.............................. 100
4.14 Allocation of siren
to an alarm group ....................... 100
4.15 Fire alarm indication................... 100
4.16 Checking..................................... 101
4.17 Deletion of parameters............... 101
5. Installing the siren............................ 102
5.1 Choosing the best place
to install the siren.......................... 102
5.2 Testing the radio range................. 102
5.3 Fixing the siren in place................ 102
6. Performing a real test...................... 104
7. Maintenance..................................... 104
7.1 Fault indications ........................... 104
7.2 Changing the battery.................... 106
8. Summary of parameters................. 106
9. Technical data .................................. 108
Recommendations
The user must not attempt to access the siren’s internal parts, except areas described in this manual. If the user does access these parts, the product guarantee will be considered null and void and DAITEM shall not be held responsible for any problems. Touching the siren’s internal parts and/or electronic components can damage the product. Furthermore, the siren is designed in such a way that these parts and components do not need to be accessed for operation or maintenance purposes.
IMPORTANT: the siren’s sound level can cause hearing disorders. Take the necessary precautions before testing the product.
93
GB
In addition to the protection provided by the control panel with built-in siren and keypad, the indoor siren
deters intruders
. If a fire is detected, the siren is triggered for 5 minutes in fire sounding mode. Thanks to its built-in transmitter, the siren informs the control panel when it has a battery problem. If somebody attempts to pull the siren off the wall, it sounds and then triggers all the alerts and deterrents via the control panel.
Vocal messages
The siren issues the following vocal messages:
1. Présentation
IMPORTANT
• Some functions are only available with versions 2.0.0 or later (press on the control panel keypad to check the version).
• The operating differences with former ranges are described in the compatibility booklet available in the Daitem installers section at www.daitem.co.uk.
Following a command
Vocal message
Commands Disarm “bip, Off”
Arm “bip, Armed” Armed Partial 1 or 2 “bip, Armed Partial 1” or “bip, Armed Partial 2” Disarm Group “bip, Off”: if all the groups allocated to the siren are disarmed
“bip, Off Group X”: if only part of the groups allocated to the siren
are disarmed
Arm Group “bip, Armed”: if all the groups allocated to the siren are armed
“bip, Armed Group X”: if only part of the groups allocated to the
siren are armed Arm Presence mode “bip, Armed Presence” Door bell “ding, dong” Disarm under duress “bip, Off”
System status query
Disarm “bip, Off” Arm “bip, Armed” Armed Partial 1 or 2 “bip, Armed Partial 1” or “bip, Armed Partial 2” Disarm group “bip, Off Group X” Arm Presence mode “bip, Armed Presence”
Alarms Intrusion when
presence mode armed
“bip, bip, bip, bip, intrusion Group X”
Entry delay “bip, bip, bip, bip, Protection Active”
Fire alarm loud sounding for 15 s then “Fire_Alarm” (alternating) Changing
siren modes
User test mode “bip, TEST_MODE” Installation mode “bip, INSTALLATION_MODE” User mode “bip, USER_MODE”
94
GB
Example: The system is in Armed Partial 2 mode but the siren has a battery fault. When the “system status query” order is sent from the keypad or remote control, the control panel and siren issue the following vocal messages:
“Bip, Armed Partial 2,
bip, Fault, System”
2. Preparing the siren
2.1 Tooling required
2.2 Opening the siren and connecting the power supply
IMPORTANT: the fixing screws and wall plugs are not supplied.
6 mm
PZ 2
1. Insert a screwdriver into the bottom right-hand corner between the base and the siren and apply pressure to open the siren.
2. Place the siren on a flat surface, remove the base by inclining it at a 45° angle (A) and pull it downwards (B).
Bip, System_status, Armed Partial 2,
bip, 12/03 at 12:00, Fault, Voltage,
Remote_Control_Unit 1”
A
45°
B
95
GB
3. Position the power pack on the guide rails.
4. Slide the power pack downwards until it is locked into place.
Coller sur certif
SH402AX
A12260A0963C
SH402AX
A12260A0963C
5. Guarantee sticker
Remove the pre-cut part of the sticker and stick it to the guarantee certificate in the user manual supplied with the control panel. If you are adding the siren to an existing system, use the guarantee sticker provided with this product.
Coller sur certif
SH402AX
A12260A0963C
SH402AX
A12260A0963C
To remove the lithium power pack, press on the unlocking key and slide the pack upwards.
Locking key
IMPORTANT
• When the siren is powered, it will issue a long beep and automatically switch to installation mode (tamper mechanism disabled).
• If the siren does not respond as it should: - disconnect the power pack,
- wait for 2 minutes,
- reconnect the lithium power pack,
- check the siren issues a long beep as it should.
IMPORTANT
• The siren does not need to be placed close to the control panel for recognition programming. In fact, it is advisable to move it away from the panel (to a distance of at least 2 m).
• The control panel gives the siren a n° during recognition programming.
3. Recognition programming
Recognition programming allows the siren to be recognised by the control panel. It must be done with the control panel and siren in installation mode. If they are not in installation mode, enter:
then
master code installer code
The control panel and siren must be in installation mode to set the siren’s parameters. If they are not, enter:
then
96
GB
IMPORTANT: the control panel and siren issue three short beeps to indicate a programming error. When this happens, perform recognition programming again from the start.
Siren recognition programming sequence.
))))) )))))
10 s max.
Briefly press
the siren “test”
button
Press and hold “Off”
until the control panel
responds
The siren issues an
audible signal to
confirm programming
The control panel
announces
the siren n°.
“bip, siren n°”“beeeep”“bip”
“bip, off,
control panel”
4. Setting the parameters
The siren’s parameters are factory-programmed. Each parameter can nevertheless be modified using the control panel keypad.
To set the siren’s parameters, first choose the parameters to be modified and then enter:
master code
installer code
parameter
siren n° parameter
value
IMPORTANT: all parameter-setting must be done using TwinLoad®software available in the Daitem installers section at www.daitem.co.uk.
“bip, installation
mode”
“bip, installation
mode”
97
GB
4.2 Duration of alarm sounding
Siren alarm sounding can be delayed by 60 seconds maximum. This gives users enough time to disarm the system before the alarm siren sounds if, for instance, they have pressed the wrong button. To delay sounding, enter:
Factory setting: 0 s
siren n° from 0 to 60 s
4.1 Delayed alarm sounding upon intrusion
To modify the duration of sounding, enter:
Factory setting: 90 s
siren n° from 20 to 180 s
For greater user-friendliness, the sound level can be increased or decreased. To do this, enter:
Factory setting: 4 = average
siren n° from 1 to 8
4.3 Sound level of arm and disarm command indications
To modify the transfer of indications, enter:
Factory setting: 2
siren n° 0: disabled
1: sounding 2: vocal message (“bip, bip, bip, bip, Off or Armed”)
4.4 Transfer of arm and disarm command indications