DAIKIN AC BRC1D71 User Guide

Remote Controller Quick Guide BRC1D71 Functions
Quick User Guide - FUNCTI O N S
BRC1D71 Controller
ON/OFF 1.
Operation Light 2.
STAND BY 3.
Current Operation Mode 4.
Off 5.
9. Day/Time
10. Central Control
11. Master Controlled
12. Airflow Direction icon
13. Fan Speed
14. MODE
selection
FUNCTION 6.
TIME 7.
Temperature
Selection buttons 8.
1. ON/OFF: Start/Stop operation of the system with the ON/ OFF button.
2. Operation Light: Lit when system is operating.
3. STAND BY: Indicates that Defrost/Hotstart mode is active.
4. Current Operation Mode display: Indicates the current
operation mode.
5. OFF: Indicates OFF is selected when programming the schedule timer.
6. FUNCTION: Multi-purpose button used to schedule the program timer. Refer to Operation Manual for further details.
7. TIME: Adjust clock or, when in programming mode, adjust
programmed action time. Both features have an
auto-repeat function.
8. Temperature Selection Buttons: Used to adjust the current setpoint or, when in programming mode, to adjust the programmed setpoint temperature. Temperature range is 60-90°F in 1°F increments. Can also be used to adjust day of the week.
9. DAY/TIME The time display indicates the current time (or the action day time when reading or programming the schedule timer). The day of the week indicator shows the current weekday (or the set day when reading or
programming the schedule timer).
10. CENTRAL CONTROL indicates that another controller with higher priority is controlling or disabling operation.
11. MASTER CONTROLLED indicates that the changeover of system is under centralized control assigned to
15. FAN SPEED
16. AIRFLOW DIRECTION
another indoor unit or optional cool/heat selector connected to the outdoor unit.
12. AIRFLOW DIRECTION: Icon Indicates airflow direction for motorized airflow louvers.
13. FAN SPEED Display: Three fan speeds, L (low), H (high), HH (higher), AUTO, and FAN, are
available. Some Daikin systems do not offer AUTO or HH, thus these options are not selectable or seen.
14. MODE selection button: Depending on prior settings, the MODE button can select operation mode:
FAN: Fan only operation (Room air is circulated). DRY: Cooling Operation Unit operates to minimize
temperature change but reduces room humidity levels. AUTO: Auto changeover Cooling and Heating switch automatically to maintain COOL: Cooling Operation − To the desired setpoint temperature. HEAT: Heating Operation − To the desired setpoint t em pe r a tu r e .
15. FAN SPEED Button: Toggles between AUTO (Automatic), L (Low), H (High), HH (Very High). Toggle only allows for available fan speeds to be selected.
16. AIRFLOW DIRECTION Button: Use to adjust airflow direction. Press the button to switch between fixed or variable airflow. Use the airflow icon to determine the fixed airflow direction by pressing the airflow button until the icon indicates the desired airflow direction.
the desired setpoint temperature.
QUG-BRC1D71_10/08
BRC1D71 Features
Qui c k U s er G u id e - FE A TUR E S
BRC1D71 Controller
AWAY 1.
Maximum Set Temp 2.
Schedule Timer 3.
Inspection Required 4.
Ventilation Mode button 6.
Minimum Set Temp 5.
10. Not Available
11. Clean Element
12. Clean Air Filter
13. Ventilation
Ventilation Amount button 7.
SCHEDULE 8.
TEST 9.
1. AWAY: The AWAY function prevents the room temperature from dropping or rising when the occupants are out for a period of time. If the room temperature drops
below 50°F, heating is started automatically. As soon as 59°F is reached, the controller returns to its original status. If the room temperature rises above 85 cooling is started automatically. As soon as 74
reached, the controller returns to its original status. ON is enabled, flashing indicates ACTIVE, if disabled it is OFF.
To ENABLE/DISABLE, press time simultaneously.
2. Maximum Set Temperature: Indicates the Maximum Set Temperature when in limit mode operation. Use the SETBACK button and MODE button to configure.
3. Schedule Timer: Indicates the Schedule Timer is enabled.
°F, °F is
14. SETBACK
15. Reset Clean Air Filter Alert
7. Ventilation Amount button: Sets the ventilation amount. (HRV System only.)
8. SCHEDULE: Enables or disables the Schedule Timer.
9. TEST: For servicing purposes only.
10. Not Available is displayed whenever a non-installed or unavailable function is requested.
11. Clean Element (HRV system only).
12. Clean Air Filter Icon indicates the air filter must be cleaned.
13. Ventilation: (HRV System only.)
14. SETBACK toggles setpoint, limit mode operation, or OFF (for programming only). Limit Mode Operation is an additional mode that enables keeping the room temperature within certain limits. The min and max icons are displayed to confirm the activation of limit operation.
4. Inspection Required: The wrench and the eye
icons indicate that inspection is required. Contact your installer.
5. Minimum Set Temperature: Indicates the Minimum Set Temperature when in limit mode operation. Use the SETBACK button and MODE button to configure.
6. Ventilation Mode button: Operates the Heat Recovery Ventilation. (HRV System only.)
QUG-BRC1D71_10/08
15. Reset Clean Air Filter Alert: Push this button after cleaning the air filter to reset the alert timer for the next necessary cleaning time.