Daikin RYN-E3V1B User Manual

• Outdoor Units • R-410A • RYN-E3V1B
1
1
• Split Sky Air • Outdoor Units
1
1 Features
Outdoor Uni Split Sky
RYN-E3V1B R-410a
Outdoor units for pair application
Daikin outdoor units are neat and sturdy and can be mounted easily on a roof or terrace or simply placed against an outside wall.
Outdoor units are fitted with a swing compressor, renowned for its low noise and high energy efficiency
3
1
2
• Split Sky Air • Outdoor Units
2
• Outdoor Units • R-410A • RYN-E3V1B
2 Specifications
2-1 NOMINAL CAPACITY AND NOMINAL INPUT
RYN50E3V1B RYN60E3V1B
For combination indoor units + outdoor units
Indoor Units FTYN50EV1B FTYN60EV1B
Cooling capacity
Standard kW 5.0 6.0
Heating capacity
Standard kW 5.8 7.0
Nominal input Cooling Standard kW 1.55 1.99
Heating Standard kW 1.60 2.04
For combination indoor units + outdoor units
EER Nominal 3.23 3.02 COP Nominal 3.63 3.43 Energy
Labeling Directive
Cooling A B Heating A B
Annual energy consumption kWh 775 995 Indoor Units FTYN50FV1B FTYN60FV1B
Cooling capacity
Standard kW 5.0 6.0
Heating capacity
Standard kW 5.8 7.0
Nominal input Cooling Standard kW 1.55 1.99
Heating Standard kW 1.60 2.04
For combination indoor units + outdoor units
EER Nominal 3.23 3.02 COP Nominal 3.63 3.43 Energy
Labeling Directive
Cooling A B Heating A B
Annual energy consumption kWh 775 995
2-2 TECHNICAL SPECIFICATIONS
RYN50E3V1B RYN60E3V1B
Casing Colour Ivory White Dimensions Unit Height mm 735 735
Width mm 825 825 Depth mm 300 300
Packing Height mm 797 797
Width mm 960 960 Depth mm 390 390
Weight Unit kg 48 48
Packed Unit kg 53 53
Heat Exchanger
Dimensions Length mm 845 845
Nr of Rows 2 2 Fin Pitch mm 1.80 1.80
Nr of Stages 32 32 Tube type Hi-Xa(8) Fin Type Waffle fin
Treatment Anti-corrosion treatment (PE)
Fan Type Propeller
Quantity 1 1 Air Flow Rate
(nominal at 230V)
Cooling m³/min 48.9 50.9
Heating m³/min 45.0 46.3
Motor Quantity 1 1
Model KFD-380-50-8A
Motor Speed
(nominal)
Cooling rpm 780 810
Heating rpm 720 740
Fan Motor Output W 53 53
• Outdoor Units • R-410A • RYN-E3V1B
1
2
• Split Sky Air • Outdoor Units
3
2 Specifications
Compressor Quantity 1 1
Motor Model 2YC36BXD#A
Type Hermetically sealed swing compressor Motor
Output
W 1100 1100
Operation Range
Cooling Min °CDB -10.0 -10.0
Max °CDB 46.0 46.0
Heating Min °CWB -15 -15
Max °CWB 18 18
Sound Level (nominal)
Cooling Sound
Power
dBA 61.0 63.0
Sound Pressure
dBA 47.0 49.0
Heating Sound
Pressure
dBA 48.0 49.0
Refrigerant Type R-410A
Charge kg 1.5 1.5
Refrigerant Oil Type FVC50K
Charged Volume l 0.65 065
Piping connections
Liquid (OD) Diameter
(OD)
mm 6.35 6.35
Gas Diameter
(OD)
mm 12.7 12.7
Drain Diameter
(OD)
mm 18 18
Piping Length Maximum m 30 30 Additional Refrigerant
Charge
kg/m 0.02/>10m
Max. internunit level difference
m 20.0 20.0
Heat Insulation Both liquid and gas pipes
Standard Accessories
Item Drain plug Quantity 1 1 Item Installation manual Quantity 1 1
Notes Nominal cooling capacities are based on : indoor temperature : 270CDB, 190CWB, outdoor temperature : 350CDB,
equivalent refrigerant piping : 7.5m, level difference : 0m.
Nominal heating capacities are based on : indoor temperature : 200CDB, outdoor temperature : 70CDB, 60CWB,
equivalent refrigerant piping : 7.5m, level difference : 0m
Sound levels are measured in an anechoic room
Sound pressure level is a relative value, depending on the distance and acoustic environment. For more details,
please refer to sound level drawings of this chapter.
The sound power level is an absolute value indicating the power which a sound source generates.
2-3 ELECTRICAL SPECIFICATIONS
RYN50E3V1B RYN60E3V1B
Power Supply Name V1
Phase 1 1 Frequency Hz 50 50 Voltage V 220-240 Voltage range Minimum V -10%
Maximum V +10%
Current Nominal
running current (RLA)
Cooling (A)
A 6.75 8.62
Heating (A)
A 6.94 8.80
Starting current (cooling/ heating)
A 7.1 9.0
Z-max List No requirements
2-2 TECHNICAL SPECIFICATIONS
RYN50E3V1B RYN60E3V1B
3
1
2
• Split Sky Air • Outdoor Units
4
• Outdoor Units • R-410A • RYN-E3V1B
2 Specifications
Wiring connections
For Power Supply
Quantity 3 3
For connection with indoor
Quantity 4 4
Remark Including earth wiring
Power Supply Intake Outdoor unit only