• Outdoor Units • R-410A • RXG-E2V1B
2
• Split Sky Air • Outdoor Units
4
2 Specifications
Compressor Quantity 1 1
Motor Model 1YC23NXD#A
Type Hermetically sealed swing compressor
Motor
Output
W 600 600
Operation
Range
Cooling Min °CDB 10.0 10.0
Max °CDB 46.0 46.0
Heating Min °CWB -15.0 -15
Max °CWB 20.0 20
Sound Level
(nominal)
Cooling Sound
Power
dBA 61.0 62.0
Sound
Pressure
dBA 46.0 47.0
Heating Sound
Pressure
dBA 47.0 48.0
Refrigerant Type R-410A
Charge kg 1.00 1.0
Control Motor operated expansion valve
Refrigerant Oil Type FVC50K
Charged Volume l 0.4 0.4
Piping
connections
Liquid (OD) Diameter
(OD)
mm 6.35 6.35
Gas Diameter
(OD)
mm 9.5 9.5
Drain Diameter
(OD)
mm 18 18
Piping Length Maximum m 20 20
Additional Refrigerant
Charge
kg/m 0.02/>10
Max. internunit level
difference
m 15.0 15.0
Heat Insulation Both liquid and gas pipes
Standard
Accessories
Item Installation manual
Quantity 1 1
Item Drain plug
Quantity 1 1
Notes Nominal cooling capacities are based on : indoor temperature : 27°CDB, 19°CWB, outdoor temperature : 35°CDB,
equivalent refrigerant piping : 7.5m, level difference : 0m.
Nominal heating capacities are based on : indoor temperature : 20°CDB, outdoor temperature : 7°CDB, 6°CWB,
equivalent refrigerant piping : 7.5m, level difference : 0m
Sound levels are measured in an anechoic room
Sound pressure level is a relative value, depending on the distance and acoustic environment. For more details,
please refer tosound level drawings of this chapter.
The sound power level is an absolute value indicating the power which a sound source generates.
2-3 ELECTRICAL SPECIFICATIONS RXG25E2V1B RXG35E2V1B
Power Supply Name V1
Phase 1 1
Frequency Hz 50 50
Voltage V 230 230
Current Nominal
running current
(RLA)
Cooling
(A)
A 3.26 4.76
Heating
(A)
A 4.36 5.06
Starting current (cooling/
heating)
A4.5 5.2
Wiring
connections
For Power
Supply
Quantity 3 3
For connection
with indoor
Quantity 4 4
Remark included earth wiring
Power Supply Intake Outdoor unit only