Daikin RXG-E2V1B Technical Data Manual

technical data
RXG-E2V1B
Outdoor Units,
Pair Application
air conditioning systems
Split Sky Air
• Split Sky Air • Outdoor Units
1
• Outdoor Units • R-410A • RXG-E2V1B
TABLE OF CONTENTS
RXG-E2V1B
1Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
2 Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Nominal Capacity and Nominal Input . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Technical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Electrical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
3 Electrical data. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
4 Capacity tables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Cooling/Heating capacity tables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
5 Dimensional drawing & centre of gravity . . . . . . . . . . . . . . . . . . . . . . . . 9
Dimensional drawing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Centre of gravity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
6 Piping diagram. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
7 Wiring diagram. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Wiring diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
8 Sound data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Sound pressure spectrum . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
9 Operation range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
• Outdoor Units • R-410A • RXG-E2V1B
1
• Split Sky Air • Outdoor Units
2
1 Features
Outdoor Uni Split Sky RXG-E2V1B R-410A
Outdoor units for pair application
Outdoor units are fitted with a swing compressor, renowned for its low noise and high energy efficiency
Daikin outdoor units are neat and sturdy and can be mounted easily on a roof or terrace or simply placed against an outside wall.
3
2
• Split Sky Air • Outdoor Units
3
• Outdoor Units • R-410A • RXG-E2V1B
2 Specifications
2-1 NOMINAL CAPACITY AND NOMINAL INPUT
RXG25E2V1B RXG35E2V1B
For combination indoor units + outdoor units
Indoor Units FTXG25EV1BW FTXG35EV1BW
Nominal Capacity
Cooling Minimum kW 1.3 1.4
Standard kW 2.5 3.5
Maximum kW 3.0 3.8
Heating Minimum kW 1.3 1.4
Standard kW 3.4 4.2
Maximum kW 4.5 5.0
For combination indoor units + outdoor units
EER Cooling 4.03 3.30
COP Heating 4.15 3.72
Energy Labeling Directive
Cooling A
Heating A
Annual energy consumption kWh 310 530
Indoor Units FTXG25EV1BS FTXG35EV1BS
Nominal Capacity
Cooling Minimum kW 1.3 1.4
Standard kW 2.5 3.5
Maximum kW 3.0 3.8
Heating Minimum kW 1.3 1.4
Standard kW 3.4 4.2
Maximum kW 4.5 5.0
For combination indoor units + outdoor units
EER Cooling 4.03 3.30
COP Heating 4.15 3.72
Energy Labeling Directive
Cooling A
Heating A
Annual energy consumption kWh 310 530
2-2 TECHNICAL SPECIFICATIONS RXG25E2V1B RXG35E2V1B
Casing Colour Ivory White
Dimensions Unit Height mm 550 550
Width mm 765 765
Depth mm 285 285
Packing Height mm 589 589
Width mm 882 882
Depth mm 363 363
Weight Unit kg 32 32
Packed Unit kg 38 38
Heat Exchanger
Dimensions Length mm 805 805
Nr of Rows 2 2
Fin Pitch mm 1.40 1.40
Nr of Stages 24 24
Tube type Hi-Xa(7)
Fin Type WH fin
Fan Type Propeller
Quantity 1 1
Air Flow Rate (nominal at 230V)
Cooling m³/min 31.30 31.3
Heating m³/min 28.10 28.1
Motor Quantity 1 1
Model D23A-28
Motor Speed
(nominal)
Cooling rpm 810 810
Heating rpm 810 810
Fan Motor Output W 35 35
• Outdoor Units • R-410A • RXG-E2V1B
2
• Split Sky Air • Outdoor Units
4
2 Specifications
Compressor Quantity 1 1
Motor Model 1YC23NXD#A
Type Hermetically sealed swing compressor
Motor Output
W 600 600
Operation Range
Cooling Min °CDB 10.0 10.0
Max °CDB 46.0 46.0
Heating Min °CWB -15.0 -15
Max °CWB 20.0 20
Sound Level (nominal)
Cooling Sound
Power
dBA 61.0 62.0
Sound Pressure
dBA 46.0 47.0
Heating Sound
Pressure
dBA 47.0 48.0
Refrigerant Type R-410A
Charge kg 1.00 1.0
Control Motor operated expansion valve
Refrigerant Oil Type FVC50K
Charged Volume l 0.4 0.4
Piping connections
Liquid (OD) Diameter
(OD)
mm 6.35 6.35
Gas Diameter
(OD)
mm 9.5 9.5
Drain Diameter
(OD)
mm 18 18
Piping Length Maximum m 20 20
Additional Refrigerant Charge
kg/m 0.02/>10
Max. internunit level difference
m 15.0 15.0
Heat Insulation Both liquid and gas pipes
Standard Accessories
Item Installation manual
Quantity 1 1
Item Drain plug
Quantity 1 1
Notes Nominal cooling capacities are based on : indoor temperature : 27°CDB, 19°CWB, outdoor temperature : 35°CDB,
equivalent refrigerant piping : 7.5m, level difference : 0m.
Nominal heating capacities are based on : indoor temperature : 20°CDB, outdoor temperature : 7°CDB, 6°CWB,
equivalent refrigerant piping : 7.5m, level difference : 0m
Sound levels are measured in an anechoic room
Sound pressure level is a relative value, depending on the distance and acoustic environment. For more details,
please refer tosound level drawings of this chapter.
The sound power level is an absolute value indicating the power which a sound source generates.
2-3 ELECTRICAL SPECIFICATIONS RXG25E2V1B RXG35E2V1B
Power Supply Name V1
Phase 1 1
Frequency Hz 50 50
Voltage V 230 230
Current Nominal
running current (RLA)
Cooling (A)
A 3.26 4.76
Heating (A)
A 4.36 5.06
Starting current (cooling/ heating)
A4.5 5.2
Wiring connections
For Power Supply
Quantity 3 3
For connection with indoor
Quantity 4 4
Remark included earth wiring
Power Supply Intake Outdoor unit only
2-2 TECHNICAL SPECIFICATIONS RXG25E2V1 B RXG35E2V1B