▪ Read the documentation carefully before operating the user
interface to ensure the best possible performance.
▪ Request the installer to inform you about the settings that he used
to configure your system. Check if he has filled in the installer
settings tables. If not, request him to do so.
▪ Keep the documentation for future reference.
Operation manual
2
Breadcrumbs help you to locate where you are in the menu structure
of the user interface. This document also mentions these
breadcrumbs.
Example: Go to [7.4.1.1]: > User settings > Preset values >
Room temperature > Comfort (heating)
2About the system
Depending on the system layout, the system can:
▪ Heat up a space
▪ Cool down a space (if a heating/cooling heat pump model is
installed)
▪ Produce domestic hot water
RHYHBH05AA + RHYHBH/X08AA
ROTEX HPU hybrid heat pump module
4P353066-1D – 2016.02
3 Operation
d
ab
c
e
f
g
BC
A
a
ef
b
d
c
2.1Components in a typical system
layout
A Main zone. Example: Living room.
B Additional zone. Example: Bedroom.
C Technical room. Example: Garage.
a Outdoor unit heatpump
b Indoor unit heatpump
c Instant domestic hot water or domestic hot water (DHW) tank
d User interface at the indoor unit
e User interface in the living room, used as room thermostat
f Radiators
g Heatpump convectors or fan coil units
3Operation
3.1Overview: Operation
You can operate the system via the user interface. This part
describes how to use the user interface:
PartDescription
At a glance▪ Buttons
▪ Status icons
Space heating/cooling
control
Domestic hot water
control
SchedulesHow to select and program schedules
Menu structureOverview of menu structure
Installer settings tableOverview of installer settings
How to control space heating/cooling:
▪ Setting the space operation mode
▪ Controlling the temperature
How to control domestic hot water:
▪ Reheat mode
▪ Scheduled mode
▪ Scheduled + reheat mode
3.2The user interface at a glance
3.2.1Buttons
a
HOME PAGES
▪ Switches between home pages (when you are on a home
page).
▪ Goes to the default home page (when you are in the menu
structure).
b
MALFUNCTION INFORMATION
If a malfunction occurs,
to display more information about the malfunction.
c
ON/OFF
Turns ON or OFF one of the controls (room temperature, leaving
water temperature, DHWtank temperature).
d
MENU STRUCTURE/BACK
▪ Opens the menu structure (when you are on a home
page).
▪ Goes up a level (when you are navigating through the
menu structure).
▪ Goes back 1step (example: when you are programming a
schedule in the menu structure).
e
NAVIGATING/CHANGING SETTINGS
▪ Navigates the cursor on the display.
▪ Navigates through the menu structure.
▪ Changes settings.
▪ Selects a mode.
f
OK
▪ Confirms a selection.
▪ Enters a submenu in the menu structure.
▪ Switches between displaying actual and desired values, or
between displaying actual and offset values (if applicable)
on the home pages.
▪ Goes to the next step (when you are programming a
schedule in the menu structure).
▪ Enables you to activate or deactivate button lock if pressed
for more than 5seconds on a home page.
▪ Enables you to activate or deactivate a function lock if
pressed for more than 5 seconds in the main menu of the
menu structure.
If you press or while changing settings, the changes
will NOT be applied.
3.2.2Status icons
IconDescription
Space operation mode = Heating.
Space operation mode = Cooling.
Operation manual
3
3 Operation
15:20
20.0°C
Mon
Room
Actual temperature
15:20
20.0°C
17:30
Actual temperature
Room
Scheduled
Mon
Tue
IconDescription
Heat pump (compressor) operation or boiler
operation. This symbol is related to the home page.
Desired room temperature = preset value (Comfort;
daytime).
Desired room temperature = preset value (Eco;
nighttime).
▪ On the room temperature home page: Desired
room temperature = according to the selected
schedule.
▪ On the DHW tank temperature home page:
DHWtank mode = Scheduled mode.
DHWtank mode = Reheat mode.
DHWtank mode = Scheduled + reheat mode.
Domestic hot water operation.
Actual temperature.
Desired temperature.
At the next scheduled action, the desired temperature
will increase.
At the next scheduled action, the desired temperature
will NOT change.
At the next scheduled action, the desired temperature
will decrease.
The preset value (Comfort or Eco) or scheduled value
is temporarily overruled.
The DHWtank booster mode is active or ready to be
activated.
Quiet mode is active.
Holiday mode is active or ready to be activated.
Button lock mode and/or function lock mode is active.
Boiler operation.
Heat pump (compressor) operation.
Boiler and heat pump (compressor) operation.
The disinfection mode is active.
A malfunction occured. Press to display more
information about the malfunction.
Weather-dependent mode is active.
User permission level = Installer.
Defrost/oil return mode is active.
Hot start mode is active.
Emergency operation is active.
INFORMATION
Boiler operation does NOT necessarily imply burner
operation. When a heating demand is sent to the boiler,
boiler operation ( ) is continuous, but the burner will ONLY
operate alternately.
3.3Space heating/cooling control
If a… heatpump model
is installed
Heating/coolingThe system can heat up and cool down a
space. You have to tell the system which
space operation mode to use.
Heating onlyThe system can heat up a space, but
NOT cool down a space. You do NOT
have to tell the system which space
operation mode to use.
To tell the system which space operation to use, you can do the
following:
You can…Location
Check which space operation mode is
currently used.
Set the space operation mode.Menu structure
Restrict when automatic changeover is
possible.
To set the space operation mode
1 Go to [4]: > Operation mode.
2 Select one of the following options and press :
If you select…Then the space operation mode is…
HeatingAlways heating mode.
CoolingAlways cooling mode.
AutomaticAutomatically changed by the software
based on the outdoor temperature
(and depending on installer settings
also the indoor temperature), and
taking monthly restrictions into
account.
Note: Automatic changeover is only
possible under certain conditions.
To restrict automatic changeover operation mode
Prerequisite: You switched the permission level to Advanced end
user.
Prerequisite: You switched the space operation mode to automatic.
1 Go to [7.5]: > User settings > Allowed operation mode.
2 Select a month and press .
3 Select Heating only, Cooling only or Heating/Cooling, and press
.
Then…
Home pages:
▪ Room temperature
▪ Leaving water
temperature (main
+ additional)
3.3.2Room thermostat control - Using the
room temperature home page
Typical room temperature home pages
Depending on the user profile, the user interface gives you either a
basic or a detailed home page. To set the user profile, refer to
Configuring user profile and home pages in the user reference
guide.
User profile = BasicUser profile = Detailed
3.3.1Setting the space operation mode
About space operation modes
Depending on your heat pump model, you have to tell the system
which space operation mode to use: heating or cooling.
Operation manual
4
RHYHBH05AA + RHYHBH/X08AA
ROTEX HPU hybrid heat pump module
4P353066-1D – 2016.02
Loading...
+ 8 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.