![](/html/70/707f/707f2e8a33e36a2ed18775a881e192e831cb1c3367b3eea01e0bf7fe4c562b89/bg2.png)
• Indoor Units • Ceiling Suspended Unit • FXHQ-MAVE
TABLE OF CONTENTS
FXHQ-MAVE
1 Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Technical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Electrical Specifications (50Hz) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Electrical Specifications (60Hz) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
2 Safety device settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
3Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
4 Control systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
5 Capacity tables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Cooling capacity tables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Heating capacity tables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
6 Dimensional drawing & centre of gravity . . . . . . . . . . . . . . . . . . . . . . . . 8
Dimensional drawing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
7 Piping diagram. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
8 Wiring diagram. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Wiring diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
9 Sound data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Sound level data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Sound pressure spectrum . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
10 Air flow pattern. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
•VRV® Systems • Indoor Units
1
![](/html/70/707f/707f2e8a33e36a2ed18775a881e192e831cb1c3367b3eea01e0bf7fe4c562b89/bg3.png)
• Indoor Units • Ceiling Suspended Unit • FXHQ-MAVE
2
•VRV® Systems • Indoor Units
![](/html/70/707f/707f2e8a33e36a2ed18775a881e192e831cb1c3367b3eea01e0bf7fe4c562b89/bg4.png)
• Indoor Units • Ceiling Suspended Unit • FXHQ-MAVE
1 Specifications
Indoor Unit VRV® Systems FXHQ-MAVE Ceiling Sus
1-1 TECHNICAL SPECIFICATIONS FXHQ32MAVE FXHQ63MAVE FXHQ100MAVE
Capacity Cooling kW 3.6 7.1 11.2
Heating kW 4.0 8.0 12.5
Power Input (50Hz) Cooling kW 0.111 0.115 0.135
Heating kW 0.111 0.115 0.135
Power Input (60Hz) Cooling kW 0.142 0.145 0.199
Heating kW 0.142 0.145 0.199
Casing Colour White (10Y9/0,5)
Dimensions Unit Height mm 195 195 195
1
1
Weight Unit kg 24 28 33
Heat Exchanger Dimensions Nr of Rows 2 3 3
Fan Type Sirocco fan
Cooling High m³/min 12 17.5 25
Low m³/min 10 14 19.5
Fan Motor Model 3D12K1AA1 4D12K1AA1 3D12K2AA1
Refrigerant Name R-410A
Cooling Sound Pressure High dBA 36 39 45
Piping connections Liquid (OD) Type Flare connection
Gas Type Flare connection
Drain Diameter mm VP20 (I.D. 20/O.D. 26)
Heat Insulation Glass wool
Air Filter Resin net with mold resistance
Refrigerant control Electronic expansion valve
Temperature control Microprocessor thermostat for cooling and heating
Safety devices Fuse
Standard Accessories Operation manual
Notes Nominal cooling capacities are based on : indoor temperature : 27°CDB, 19°CWB, outdoor temperature
Width mm 960 1,160 1,400
Depth mm 680 680 680
Fin Pitch mm 1.75 1.75 1.75
Face Area m² 0.182 0.233 0.293
Nr of Stages 12 12 12
Output (high) W 62 62 130
Drive Direct drive
Low dBA 31 34 37
Diameter mm 6.35 9.52 9.52
Diameter mm 12.7 15.9 15.9
Fan motor thermal protector
Installation manual
Drain hose
Paper pattern for installation
Clamp metal
Insulation for fitting
Clamps
Washer
: 35°CDB, equivalent refrigerant piping : 7.5m (horizontal)
Nominal heating capacities are based on : indoor temperature : 20°CDB, outdoor temperature : 7°CDB,
6°CWB, equivalent refrigerant piping : 7.5m (horizontal)
Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat.
3
•VRV® Systems • Indoor Units
![](/html/70/707f/707f2e8a33e36a2ed18775a881e192e831cb1c3367b3eea01e0bf7fe4c562b89/bg5.png)
• Indoor Units • Ceiling Suspended Unit • FXHQ-MAVE
1 Specifications
1-2 ELECTRICAL SPECIFICATIONS (50HZ) FXHQ32MAVE FXHQ63MAVE FXHQ100MAVE
Power Supply Name VE
Phase 1~
Frequency Hz 50
Voltage V 220-240
Current Minimum circuit amps (MCA) A 0.8 0.8 0.9
Maximum fuse amps (MFA) A 15 15 15
Full load amps (FLA) A 0.6 0.6 0.7
Voltage range Minimum V -10%
1
Notes Voltage range : units are suitable for use on electrical systems where voltage supplied to unit terminals
1
Maximum V +10%
is not below or above listed range limits.
Maximum allowable voltage range variation between phases is 2%.
MCA/MFA : MCA = 1.25 x FLA
MFA is smaller than or equal to 4 x FLA
Next lower standard fuse rating minimum 15A
Select wire size based on the MCA
Instead of a fuse, use a circuit breaker
1-3 ELECTRICAL SPECIFICATIONS (60HZ) FXHQ32MAVE FXHQ63MAVE FXHQ100MAVE
Power Supply Name VE
Phase 1~
Frequency Hz 60
Voltage V 220
Current Minimum circuit amps (MCA) A 0.9 0.9 1.3
Maximum fuse amps (MFA) A 15 15 15
Full load amps (FLA) A 0.7 0.7 1.0
Voltage range Minimum V -10%
Maximum V +10%
Notes Voltage range : units are suitable for use on electrical systems where voltage supplied to unit terminals
Maximum allowable voltage range variation between phases is 2%.
is not below or above listed range limits.
MCA/MFA : MCA = 1.25 x FLA
MFA is smaller than or equal to 4 x FLA
Next lower standard fuse rating minimum 15A
Select wire size based on the MCA
Instead of a fuse, use a circuit breaker