Daikin EHS157034, EHS157068 Operation manuals

Operating instructions
Daikin Controller RoCon HP, EHS157034, EHS157068
Operating instructions
Daikin Controller RoCon HP, EHS157034, EHS157068
English
Daikin RoCon HP EHS157034 EHS157068
1 Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
1.1 Observing instructions . . . . . . . . . . . . . . . . . . . . 4
1.2 Warning signs and explanation of symbols . . . . 4
1.2.1 Meaning of the warnings. . . . . . . . . . . . . . . . . . . . .4
1.2.2 Validity. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
1.2.3 Handling instructions. . . . . . . . . . . . . . . . . . . . . . . .5
1.2.4 Display readouts of the RoCon-Controller . . . . . . .5
1.3 Avoiding danger . . . . . . . . . . . . . . . . . . . . . . . . . 5
1.4 Proper use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
2 Product description. . . . . . . . . . . . . . . . . . . 6
3 Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
3.1 General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
3.2 Display and operating elements. . . . . . . . . . . . . 7
3.2.1 Display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
3.2.2 Operating elements. . . . . . . . . . . . . . . . . . . . . . . . .9
3.3 Operating concept . . . . . . . . . . . . . . . . . . . . . . 10
3.4 Basic functions and operating modes . . . . . . . 11
3.4.1 System information (Info) . . . . . . . . . . . . . . . . . . .11
3.4.2 Setting the operating mode. . . . . . . . . . . . . . . . . .13
3.4.3 Temperature setting Daytime room temperature .15
3.4.4 Temperature setting Economy mode . . . . . . . . . .15
3.4.5 Temperature setting hot water generation . . . . . .15
3.4.6 Unscheduled hot water generation . . . . . . . . . . . .15
3.4.7 Switching time program. . . . . . . . . . . . . . . . . . . . .16
3.4.8 System settings. . . . . . . . . . . . . . . . . . . . . . . . . . .18
3.4.9 Terminal function. . . . . . . . . . . . . . . . . . . . . . . . . .18
3.4.10 Quite Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19
3.4.11 SMART GRID (SG). . . . . . . . . . . . . . . . . . . . . . . .20
3.5 Special functions . . . . . . . . . . . . . . . . . . . . . . . 20
3.5.1 Manual Operation . . . . . . . . . . . . . . . . . . . . . . . . .20
3.5.2 Reference run 3-way diverter valve . . . . . . . . . . .21
3.6 Special system settings . . . . . . . . . . . . . . . . . . 21
3.6.1 Access Rights (Technician password) . . . . . . . . .21
3.6.2 Heat curve. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22
3.6.3 Cooling characteristic curve . . . . . . . . . . . . . . . . .23
3.6.4 Weather-controlled flow temperature regulation . .24
3.6.5 Frost protection function . . . . . . . . . . . . . . . . . . . .24
3.6.6 Interlink function . . . . . . . . . . . . . . . . . . . . . . . . . .25
3.6.7 Additional alternative heat generator . . . . . . . . . .25
3.6.8 Heating support. . . . . . . . . . . . . . . . . . . . . . . . . . .26
3.6.9 Special function: Switching contacts . . . . . . . . . . .26
3.6.10 Air Purge . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26
3.6.11 Legionella protection. . . . . . . . . . . . . . . . . . . . . . .27
3.6.12 Reset to factory settings (Reset) . . . . . . . . . . . . . .27
3.6.13 Screed Program . . . . . . . . . . . . . . . . . . . . . . . . . .28
3.6.14 Relay Test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .30
3.6.15 Settings for optional circulation pump . . . . . . . . . .30
3.6.16 Remote control via Internet . . . . . . . . . . . . . . . . . .31
4 Initial start-up. . . . . . . . . . . . . . . . . . . . . . . 32
4.1 Fundamental aspects of the IDs and
authorisations in the RoCon system . . . . . . . . 32
4.2 Operating Support during 1st. Commissioning
and during System Extensions . . . . . . . . . . . . 34
4.3 Starting up the Daikin Altherma EHS(X/H). . . . 34
4.3.1 Allocating the terminal ID on the control unit
RoCon B1 of the Daikin Altherma EHS(X/H) . . . .34
4.4 Commissioning optional RoCon
system components . . . . . . . . . . . . . . . . . . . . . 34
4.4.1 Mixer module EHS157068 . . . . . . . . . . . . . . . . . .34
4.4.2 Room station EHS157034. . . . . . . . . . . . . . . . . . .35
4.4.3 Allocating mixing module EHS157068 to a
heat generator. . . . . . . . . . . . . . . . . . . . . . . . . . . .36
4.4.4 Master-RoCon function . . . . . . . . . . . . . . . . . . . . .36
4.4.5 Caretaker function . . . . . . . . . . . . . . . . . . . . . . . . 36
5 Parameter Overview . . . . . . . . . . . . . . . . . .37
5.1 For first commissioning or resetting to
factory settings . . . . . . . . . . . . . . . . . . . . . . . . 37
5.2 After first commissioning / after successful
basic configuration . . . . . . . . . . . . . . . . . . . . . 38
5.2.1 Rotary switch setting: Configuration . . . . . . . . . . 38
5.2.2 Rotary switch setting: DHW Install . . . . . . . . . . . 39
5.2.3 Rotary switch setting: Operating Mode . . . . . . . 39
5.2.4 Rotary switch setting: Set Temp Day . . . . . . . . . 39
5.2.5 Rotary switch setting: Set Temp Night . . . . . . . . 39
5.2.6 Rotary switch setting: DHW Set Temp . . . . . . . . 39
5.2.7 Rotary switch setting: Time Program . . . . . . . . . 39
5.2.8 Rotary switch setting: Remote Param . . . . . . . . 39
5.2.9 Rotary switch setting: Info . . . . . . . . . . . . . . . . . 39
5.2.10 Exit button: Sonderfunktion . . . . . . . . . . . . . . . . . 39
5.3 Parameter levels for the EHS157068
mixer module. . . . . . . . . . . . . . . . . . . . . . . . . . 39
5.3.1 Rotary switch setting: Info . . . . . . . . . . . . . . . . . 39
5.3.2 Rotary switch setting: Operating Mode . . . . . . . 39
5.3.3 Rotary switch setting: Set Temp Day . . . . . . . . . 39
5.3.4 Rotary switch setting: Set Temp Night . . . . . . . . 39
5.3.5 Rotary switch setting: DHW Set Temp . . . . . . . . 39
5.3.6 Rotary switch setting: DHW Install . . . . . . . . . . . 39
5.3.7 Rotary switch setting: Time Program . . . . . . . . . 40
5.3.8 Rotary switch setting: Remote Param . . . . . . . . 40
5.3.9 Rotary switch setting: Configuration . . . . . . . . . . 40
6 Parameter settings . . . . . . . . . . . . . . . . . . .41
6.1 Explanation of the parameter tables . . . . . . . . 41
6.2 Rotary switch setting: Configuration . . . . . . . . 41
6.2.1 Level "Setup". . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
6.2.2 Level "System " . . . . . . . . . . . . . . . . . . . . . . . . . . 45
6.2.3 Level "HC Configuration". . . . . . . . . . . . . . . . . . . 46
6.2.4 Level "DHW Configuration" . . . . . . . . . . . . . . . . . 48
6.3 Rotary switch setting: DHW Install . . . . . . . . . 48
6.4 Rotary switch setting: Operating Mode . . . . . 48
6.5 Rotary switch setting: Set Temp Day . . . . . . . 49
6.6 Rotary switch setting: Set Temp Night . . . . . . 49
6.7 Rotary switch setting: DHW Set Temp . . . . . . 49
6.8 Rotary switch setting: Time Program . . . . . . . 50
6.9 Rotary switch setting: Remote Param . . . . . . 50
6.10 Rotary switch setting: Info . . . . . . . . . . . . . . . 51
6.11 Exit button: Sonderfunktion . . . . . . . . . . . . . . . 51
6.12 Parameter level "Basic Configuration" . . . . . . 52
6.13 Parameter levels for the EHS157068
mixer module. . . . . . . . . . . . . . . . . . . . . . . . . . 52
6.13.1 Rotary switch setting: Configuration,
level "Setup" . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53
6.13.2 Rotary switch setting: Configuration,
level "Mixer Config" . . . . . . . . . . . . . . . . . . . . . . . 54
7 Errors, malfunctions and messages . . . . .56
7.1 Recognising errors, correcting malfunctions. . 56
7.1.1 Current fault display . . . . . . . . . . . . . . . . . . . . . . 56
7.1.2 Read Protocol . . . . . . . . . . . . . . . . . . . . . . . . . . . 56
7.1.3 Troubleshooting. . . . . . . . . . . . . . . . . . . . . . . . . . 56
7.2 Emergency operation . . . . . . . . . . . . . . . . . . . 57
7.3 Malfunctions and fault codes. . . . . . . . . . . . . . 57
8 Glossary. . . . . . . . . . . . . . . . . . . . . . . . . . . .58
Operating instructions
2
Daikin RoCon HP
Daikin Controller
008.1420844_13 – 02/2016
9 Notes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .59
9.1 User-specific settings . . . . . . . . . . . . . . . . . . . .59
9.1.1 Switching timer program . . . . . . . . . . . . . . . . . . . 59
9.1.2 Parameter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60
9.1.3 IDs in the RoCon CAN bus system . . . . . . . . . . . 60
9.2 Other items . . . . . . . . . . . . . . . . . . . . . . . . . . . .61
10 List of keywords . . . . . . . . . . . . . . . . . . . . .63
List of contents
Daikin RoCon HP Daikin Controller
008.1420844_13 – 02/2016
Operating instructions
3
1 x Safety

1 Safety

1.1 Observing instructions

These instructions are a >> translation of the original version << in your language.
All the activities required for operation and setting the parameters are described in this in­struction manual. All parameters needed for trouble-free operation have been configured at the factory.
Please read through this manual carefully before operating the heating system or before adjusting the settings for it.
Make a note of the preset values before you make any changes to the unit configuration.
Relevant documents
– Daikin Altherma EHS(X/H):
– Installation and maintenance instructions – Operating instructions for the user/owner – Commissioning checklist
– External unit for Daikin Altherma EHS(X/H);
the associated installation and operating instructions.
– When connecting to a solar system; the asso-
ciated installation and operating instructions.
– If a Daikin FWXV(15/20)AVEB is connected;
the associated installation and operating instructions.
– If a different heater or optional accessories
are connected; the associated installation and operating instructions.
The guides are included in the scope of supply for the individual units.

1.2 Warning signs and explanation of symbols

1.2.1 Meaning of the warnings

Warnings in this manual are classified according into their severity and probability of occurrence.
DANGER!
Draws attention to imminent danger.
Disregarding this warning can lead to se­rious injury or death.
WARNING!
Indicates a potentially dangerous situ­ation.
Disregarding this warning may result in serious physical injury or death.
CAUTION!
Indicates a situation which may cause possible damage.
Disregarding this warning may cause damage to property and the envi­ronment.
This symbol identifies user tips and par­ticularly useful information, but not warn­ings or hazards.
Special warning signs
Some types of danger are represented by special symbols:
Operating instructions
4
Electric current
Risk of burning or scalding
Daikin RoCon HP
Daikin Controller
008.1420844_13 – 02/2016
1 x Safety

1.2.2 Validity

Some information in this manual has limited va­lidity. The validity is highlighted by a symbol.
Only valid for Daikin Altherma EHS(X/H) with cooling function
Valid/available only if a room station (EHS157034) is connected
Valid/available only if a mixer module (EHS157068) is connected

1.2.3 Handling instructions

Handling instructions are shown as a list. Actions of which the sequential order must be maintained are numbered.
Results of actions are identified with an
arrow.
1.2.4 Display readouts of the RoCon-
Controller
Entry into a setting procedure
Exit from a setting procedure
Certain screen displays or menu points may differ from those shown in these instructions due to country or equipment variations in the Daikin Altherma EHS(X/H) or the status of the user logged onto the Controller.

1.3 Avoiding danger

WARNING!
This equipment must only be used by
children aged 8 and above and by
persons with restricted physical, sensory or mental capabilities or with a lack of ex­perience and knowledge, if they are under supervision or if they have been instructed in the safe use of the equipment and understand the dangers
arising therefrom. Children must not
play with the equipment. Cleaning or
user maintenance must not be carried out by children without supervision.

1.4 Proper use

The RoCon HP may be used only in Daikin Altherma EHS(X/H) heat pumps that have been approved for Daikin the regulating system­RoCon. The Daikin RoCon HP may only op­erated only according to the indications in this manual.
Any other use outside the intended use is con­sidered as improper. The operator alone shall bear responsibility for any resulting damage.
For any work on the equipment, which extends above and beyond the operation of the regu­lating system, you must observe the details pro­vided in the supplementary documents, particu­larly with regard to safety instructions.
The Daikin Altherma EHS(X/H) is state-of-the­art and is built to meet all recognised technical requirements. However, improper use may result in serious physical injuries or death, as well as property damage.
To avoid danger, only operate the Daikin Altherma EHS(X/H): – as stipulated and in perfect condition, – with an awareness of safety and the hazards
involved.
This assumes knowledge and use of the con­tents of this manual, of the relevant accident pre­vention regulations as well as the recognised safety-related and occupational health rules.
Daikin RoCon HP Daikin Controller
008.1420844_13 – 02/2016
Operating instructions
5
2 x Product description

2 Product description

The Controller RoCon HP is part of the Daikin Altherma EHS(X/H).
It consists of the RoCon BM1 control panel to which
the actuators and sensors, as well as other compo­nents in the Daikin RoCon r
egulating system, are con-
nected, and the RoCon B1 operating unit.
In this instruction manual we explain just the functions and setting possibilities of the Controller. More infor­mation on the Daikin Altherma EHS(X/H) and other equipment components can be found in the supple­mentary documents.
The electronic, digital Controller is a
ble to automatically control all heating, cooling and hot water functions for a direct heating circuit, a storage tank charging circuit and optionally connectable mixer module, depending on the heating unit in question.
It is responsible for all safety management functions of the Daikin Altherma EHS(X/H). This executes a safety switch-off in
nt of a water shortage or undefined operating states.
the eve A corresponding fault message shows the operator all the infor­mation for fault causes.
All function settings for the Daikin Altherma EHS(X/H) and the optional RoCon devices connected via the data bus are carried out with the operating elements of the integrated RoCon B1
trol panel and displayed in clear text display on a coloured
con backlit display.
The regulation data bus can be used to connect the Daikin Altherma EHS(X/H) to the following optional equipment:
S157034 room station
EHEHS157068 mixer module.
The Controller RoCon HP contains a timer which can be used to
t:
se – 2 individually-adjustable timer programmes
(2
for room heat-
ing and room cooling (direct heating circuit),
– 2 individually-adjustable timer programmes for hot water gen-
eration,
– 1 individually-adjustable timer programme for an optional cir-
culation pump.
(2 Use of the timer programme for room cooling only possible in combination with
a connected room thermostat
Initial commissioning of the heating system is described in the in­stallation manual for the Daikin Altherma EHS(X/H).
Certain menu items in the Controller RoCon HP are only acces­sible to the specialist heating technician. This security measure ensures that no undesirable malfunctions arise during operation of the system through incorrect settings.
The EHS157034 room station has th
e same operating panel as the Daikin Altherma EHS(X/H) B1 operating element integrated in the RoCon B1.
All settings for the allocated heating circuit can be carried out in the same way as the operating unit. With activated terminal function, all operating possibilities that are available on the inte­grated operating unit are available, with th
e exception of certain
special functions (e.g. Manual Operation).
An EHS157068 connected mixer module will also be operated, after appropriate allocation, by the RoCon B1 control unit and/or the EHS157034 room station.
In addition, the RoCon HP control unit has a frost protection functio
n for the direct heating circuit and the storage tank charging circuit, as well as an automatic function for heating support (inclusion of an additional source of heat such as a wood­burning boiler or solar installation).
The potential-free AUX switching contact can
be used to carry out different control functions in conjunction with external devices (demand from an external heat generator, switching to bivalent operating mode, external status display, etc.).
In addition, it also has several inputs for assessing external
trol contacts (external operating mode switching or heat
con demand, SMART GRID- and low-tariff EVU functions
(1 Energy supply company (EVU) sends signals that are used for controlling the
power mains loading, and which have an influence on the cost of the power and availability.
(1
.
The weather-controlled flow temperature regulation can be opti-
mised with the RoCon OT1 optional external temperature probe
which can be installed on the north face of the building.
If the EHS157056 optional gateway is installed and connected to
the Internet, the Daikin Altherma EHS(X/H) can be conveniently monitored and operated by remote control using a mobile phone (app).
Operating instructions
6
Daikin RoCon HP
Daikin Controller
008.1420844_13 – 02/2016

3 Operation

3 x Operation

3.1 General

DANGER! If electrical components come into con-
tact with water, this can cause an elec­tric shock as well as potentially fatal
injuries and burns.
The displays and the buttons on the Controller must be protected from the effects of moisture.
To clean the Controller use a dry cotton cloth. Using aggressive cleaning agents and other liquids can cause damage to equipment or lead to an electric shock.
Maximum energy utilisation
The most effective energy utilisation is achieved by the Daikin Altherma EHS(X/H) at the lowest possible return flow and hot water temperatures.
If an external heat generator (e.g. the optional Backup Heater) is used at inflow target temperatures of over 50 °C, the efficiency (COP) of the Daikin Altherm (depending on the outside temperature).
a EHS(X/H) can be affected negatively

3.2 Display and operating elements

1 Clear text display 2 Setting: Configuration 3 Setting: Remote Param 4 Rotary switch 5 Setting: Info 6 Setting: Operating Mode
Fig. 3-1 Arrangement of display and operating elements
7 Setting: Set Temp Day 8 Setting: Set Temp Night 9 Setting: DHW Set Temp 10 Rotary button 11 Setting: DHW Install 12 Setting: Time Program 13 Exit button
Daikin RoCon HP Daikin Controller
008.1420844_13 – 02/2016
Operating instructions
7
3 x Operation

3.2.1 Display

All the operating steps are supported by appropriate displays in a clear text display on a coloured background.
Menu navigation is available in 7 different languages (see section 3.4.8).
Malfunctions are generally indicated by a fault code and a clear text fault message on the display.
For troubleshooting instructions refer to chapter 7.
The colour of the backlighting indicates the operational status and the operational mode:
White: Standard lighting, normal operational display.
Red: Fault status, depending on
Daikin Altherma EHS(X/H) continues to function with restrictions.
Green: Operating mode with operator authorisation.
Blue: Operating mode with expert technician authori-
sation.
the type of fault, the
1 Date display 2 Status of refrigerant com-
pressor
3 Status display (e.g. Techni-
cian access rig 4 Display time 5 Current flow temperature 6 Status heating circuit
Fig. 3-2 Display of the Controller - standard display
hts active)
7 Current outdoor temperature 8 Active operating mode 9 Status of hot water genera-
tion
10 Current storage tank temper-
ature
Operating instructions
8
Daikin RoCon HP
Daikin Controller
008.1420844_13 – 02/2016
Explanation of symbols
Item
fig. 3-2
2 / 3 Air Purge active (see section 3.6.10)
2 / 3
2 / 3
2 / 3 "Party" temporary timer programme active
2 / 3
2 / 3 "Holiday" temporary timer programme
2 / 3 "Vacation" temporary timer programme
2 / 3
Symbol Explanation
2
Flashing: Heat pump demand active
Permanently on: Refrigerant compressor is working
2 No connection to the external heat pump
unit
3
Access Rights Expert active (see section 3.6.1)
Terminal function active (see section 3.4.9)
Frost protection function active (see section 3.6.5)
(see section 3.4.7)
"Away" temporary timer programme active (see section 3.4.7)
active (see section 3.4.7)
active (see section 3.4.7)
Screed Program active (see section 3.6.13)
5 Direct heating circuit
– Under normal conditions, the current
inflow temperature t
V, BH
is displayed.
– In the case of no demand from the heat
pump, the abbreviation "ES" is dis­played instead of the current flow tem­perature.
The control system has switched to
energy saving mode (see
section 3.4.2). Superfluous elec­tronic components are switched off.
5
5 Room temperature sensor
6 Heating circuit status
7 Outside temperature sensor
Mixer circuit
The current inflow temperature of the se­lected heating circuit is displayed.
The current room temperature is displayed.
– Heating circuit active (room heating
function)
– Heating circuit active (room cooling
function)
– Heating circuit not active (currently no
heat transfer in the heating circuit)
The current outside temperature is dis­played.
3 x Operation
Item
fig. 3-2
Tab. 3-1 Explanation of display symbols

3.2.2 Operating el eme n ts

If special key combinations or extended key pushes are required for certain function, a separate note is made in each specific section of this description.
Rotary switch
The rotary switch is used to gain rapid direct access (main function level) to frequently required functions and setting op­tions.
Tab. 3-2 Function of rotary switch
Symbol Explanation
8 Current operating mode (see section 3.4.2)
Standby active.
Reducing active.
Heating active.
Cooling active.
Summer active.
Automatic 1 active.
Automatic 2 active.
9
Domestic hot water generation active
Domestic hot water generation not active
10
Domestic hot water circuit status
The current storage tank temperature t
is displayed.
DHW1
CAUTION!
Never operate the operating elements on the controller with a hard, pointed object. This can cause damage and can cause the control unit to malfunction.
Independent of the setting of the rotary switch, the Daikin Altherma EHS(X/H) operates in accordance with
the operating mode set in the "Operating Mode"
switch position or that has been activated by a
special programme.
Action Result
Rotating
Direct selection of the main function level allo­cated to this switch position.
Daikin RoCon HP Daikin Controller
008.1420844_13 – 02/2016
Operating instructions
9
3 x Operation
Rotary switch
The rotary switch can be used to navigate in the individual levels, setting values can be selected, changed and these changes can then be accepted by pressing briefly.
Action Result
Rotating
To the right (+): Increased regulation
To the left (–): Reduced regulation
Pressing
Confirm, accept, selection and execute the function.
Tab. 3-3 Functions of the rotary switch
1 Info (section 3.4.1) 2 Operating Mode (section 3.4.2) 3 Set Temp Day (section 3.4.3) 4 Set Temp Night (section 3.4.4) 5 DHW Set Temp (section 3.4.5) 6 DHW Install (section 3.4.6) 7 Time Program (section 3.4.7) 8 Configuration (section 3.4.8) 9 Remote Param (section 3.4.9)
Fig. 3-3 Illustration of main function level (rotary switch position)
Exit button
This button can be used to jump back to the previous display within a menu display or a function / input can be interrupted.
This button can also be used to call up the special level (see section 3.5).
Action Result
Brief pressing.
– Jump back to the previous display or pre-
vious level or
– Cancellation of a special function or an
ctive temporary timer programme.
a
Pressfor more
– Special level is called up.
than 5 secs.
Tab. 3-4 Functions of the exit button

3.3 Operating concept

The operating concept for controlling the RoCon HP is structured in such a way that the frequently required settings options are ac-
cessible quickly and directly at the ma using the rotary switch), while the less frequently required set-
tings options are arranged at a lower parameter level.
in function level (selection
Certain functions and parameters are restricted by access au­thorisation and can only be adjusted by the heating technician (see section 3.6.1).
In normal operating mode the rotary switch should be in position .
After switching on and successful initialisation, the display auto­matically shows the standard display with rotary switch position
.
In the first commissioning, the setting for language selection is displ
ayed first.
Select the language using the rotary switch. onfirm the changes with a brief push of the rotary switch.
C
Adaption to the special installation configuration is
carried out in the "Configuration" rotary switch
position (see section 3.4.8).
When the system is switched on, based on the stipulations s
et in the Controller RoCon HP, it fully automatically regulates the operation of the – room heating, room cooling and the – sanitary hot water generation.
Independent of the setting of the rotary switch, the Daikin Altherma EHS(X/H) operates in accordance with
the operating mode set in the "Operating Mode"
switch position or that has been activated by a
special programme.
Operating instructions
10
If the user enters a value manually, this setting remains active until the user changes it or until the programme clock forces an­other operating mode.
Daikin RoCon HP
Daikin Controller
008.1420844_13 – 02/2016
3 x Operation
Keylock Function
On
Keylock Function
Keylock Function
Off
The operating mode can be affected by additional functions such as: – Weather-controlled flow temperature regulation – Switching time program – Setting the temperature target value – Setting at the room station – Setting on room thermostat – Switch status at EXT input (external
operating mode switcho-
ver) – Switch status at EBA input (external demand request) – Quite Mode – Interlink fct – Switch status at SMART GRID input
(EVU function SMART
GRID) – Switch ststus at EVU input (EVU function HT/NT (low tariff) or
ART GRID)
SM – Defrosting function – Frost protection function – Screed function –Air Purge – Manual Operation
Button block
The operating panel on the RoCon HP can be blocked to prevent inadvertent actuation (see fig. 3-4).
Unlocking can be carried out in the same way.
The prerequisite for this function is that, in the level "Setup", the parameter [Keylock Function] is set to "On" (see chapter 6.2.1 tab. 6-1).

3.4 Basic functions and operating modes

If the storage temperature falls below a certain minimum value, the safety settings of the Daikin Altherma EHS(X/H) prevent the operation of the heat pump in the case of low external temperatures:
Extern
Extern
Without backup heater: The storage tank water must be heated to the minimum required storage temperature by an external heater.
With backup heater (EKBUxx): With an outdoor temperature < 12 °C and a storage tank temperature < 35 °C, the backup heater (BUH) is switched on automatically on in order to heat up the storage tank water to at least 35 °C.
I
Automatic defrosting function
At low outdoor temperatures and corresponding humidity values, the external heat pump unit may ice up. This icing impairs effi­cient operation. The system detects this condi and starts the defrosting function.
During the defrosting function, heat is drawn from the hot water storage tank and the backup heater is turned on if required. Depending on the heat demand for the defrosting function,
ting of the direct heating circuit may be interrupted tempo-
hea rarily.
After 8 minutes at most, the system returns to normal mode.
al temperature < -2 °C, minimum storage
temperature = 30 °C
al temperature < 12 °C, minimum storage
temperature = 23 °C.
n order to accelerate the heating process with the back-up heater, temporarily – Parameter [Function Heating ] = "1" and – Set parameter [Power DHW] to t
he maximum
value of the back-up heater.
– Set rotary switch to the operating mode and
parameter [1x Hot Water] to "On".
tion automatically
Fig. 3-4 Activating button lock (1.) and deactivating (4.)

3.4.1 System information (Info)

In this rotary switch position, the rotary switch can be used to call up all the system temperatures, the type of Daikin Altherma EHS(X/H), various software information and the oper­ating statuses of all system compon
ents, one after the other. The number of displayed parameters depends on the connected components.
No settings can be made to these values.
Place the rotary switch in the "Info" position.
Standard display is shown (see fig. 3-2).
Press the
rotary switch briefly.
The parameter overview is displayed.
Select the desired information level with the rotary switch.
Con
firm the changes with a brief push of the rotary switch.
The value is displayed (for example, see fig. 3-6).
Sele
More detailed explanations and possible setting values for this rotary switch setting can be seen in tab. 3-5 and in chapter 6.10.
ct the individual information with the rotary switch.
Daikin RoCon HP Daikin Controller
008.1420844_13 – 02/2016
Operating instructions
11
3 x Operation
Info
Overview
Water Pressure
Off
Display operating data overview
The current operating data for the Daikin Altherma EHS(X/H) are shown on the RoCon HP Controller in the "Overview" information
vel.
le
The display of the operating data is not divided into several windows. By adjusting the rotary switch it is toggled between the windows.
Short
designation
Mode Current mode of the heat pump:
Ext Current energy mode of the heat pump:
Page 1
RT Parameter [Room thermostat] / [Interlink fct]
Pump Actual output of the internal heating circulation
EHS Current output of the backup heater in kW
BPV Current position of the mixing valve 3UVB1
TV Current inflow temperature after the plate heat
TVBH Current heating inflow temperature or temp. after
TR Current heating return flow temperature (t
Tdhw Current temperature in domestic hot water
Page 2
TA Actual outdoor temperature (measured by op-
V Actual volume flow (flow rate) in the heating
Explanation of the displayed value
- - - : No heating or cooling demand : Heating : Cooling : Domestic hot water generation : Automatic defrosting function active
LT: EVU function HT/NT active and low tariff. HT: EVU function HT/NT active and high tariff. SGN: EVU function SMART GRID active, normal mode. SG1: EVU function SMART GRID active, discon­nection: no heat pump operation, no frost protection function
. SG2: EVU function SMART GRID active, switch­on recommendation, mode with higher set temperatures, cheap power. SG3: EVU function SMART GRID active, switch­on command and storage tank charging to 70 °C,
power
cheap
- - -: No external mode active, heat pump works in normal mode.
= Off: - - -
Parameter [Room thermostat] = On: – : Heating or cooling demand
: No heating demand
Parameter [Interlink fct] = On (priority): – - - -: only frost protection – IL1: normal inflow target temperature – IL2:
– increased inflow target temperature in
ating operation
he
– decreased inflow target temperature in
ling operation
coo
pump in %
(100% = A, 0% = B)
exchanger (tV1)
hea
ting support heat exchanger (t
stora
ge tank (t
DHW1
)
V, BH
)
)
R1
tional temperature sensor RoCon OT1)
sy
stem
Short
Explanation of the displayed value
designation
TVBH2 = TVBH
TR2 Current heating return flow temperature, sec-
ondary sensor (tR2)
Tdhw2 Current temperature in domestic hot water
storage
tank, secondary sensor (t
Page 3
Tliq2 Current coolant temperature (tL2)
DHW2
)
TA2 Actual outdoor temperature (measured by tem-
perature sensor of the external heat pump)
quiet Shows the status of the whisper mode
Tab. 3-5 Description of the operating data displayed as an overview
Fig. 3-5 Display operating data overview
Operating instructions
12
Daikin RoCon HP
Daikin Controller
008.1420844_13 – 02/2016
3 x Operation
Info
Overview
Water Pressure
T-HS
Water Pressure
Operating Mode
Standby
Reducing
Operating Mode
Heating
Cooling
Summer
Operating Mode
Summer
Automatic 1
Automatic 2
Operating Mode
Summer
Automatic 1
Automatic 2
Displaying the water pressure
On the Controller RoCon HP, when it is switched on, you can display the system pressure (water pressure) in the internal circuit (direct heating circuit). The water pressure is available as the first info parameter after the operating data overview (see fig. 3-6).
The permissible range of water pressure during operation de­pends on the Daikin Altherma EHS(X/H) and the heating system.
he set values and threshold values must only be changed by the
T heating technician. If the water pressure falls below the minimum value (set parameter value), it must be increased by topping up the system (see installation instructions of the Daikin Altherma EHS(X/H), chapter "Inspection and Maintenance").
The pressure limits for the safety switch-off and the set pressure can be adjusted in the parameter settings in level "System ".

3.4.2 Setting the ope rating mode

The selection of the operating mode with which the Daikin Altherma EHS(X/H) is to operate is undertaken on the rotary switch in th
The selected operating mode is activated by briefly pushing the rotary switch.
e setting "Operating Mode" .
Fig. 3-6 Info values display (e.g. system pressure)
Daikin RoCon HP Daikin Controller
008.1420844_13 – 02/2016
Fig. 3-7 Switching the operating mode
(e.g.: from "Standby" to "Automatic 1")
Place the rotary switch in the "Operating Mode"
position.
An overview is displayed.
Sele
Confirm the changes with a brief push of the rotary switch.
ct the desired operating mode with the rotary switch.
Daikin Altherma EHS(X/H) operates in accordance with
the set operating mode.
The current operating mode is indicated by an appropriate
symbol in the standard display.
Operating mode Standby (Stand-by)
CAUTION!
A heating system that is not frost-pro­tected can freeze in cold weather and be damaged.
Drain
the water out of the heating
system if there is a danger of frost.
If the heating system is not drained and there is a risk of frost, the power supplies must be secured and the external main switch must remain switched on.
In this mode, the Daikin Altherma EHS(X/H) is shifted to the
stand-by mode. The frost-protection function
(see section 3.6.5) remains in place. In order function, the system must not be disconnected from the mains!
to maintain this
Operating instructions
13
3 x Operation
All controllers integrated into the RoCon-system via the CAN bus are also switched at a higher level to the operating mode "Standby".
Fig. 3-8 Standard display in "Standby" operating mode
(above the frost-protection limit)
In the "Standby" operating mode, the heat pump and any optionally connected backup heaters are isolated
from the power supply (Energy saving mode) when
the following conditions are met:
– The outdoor temperature sensor (RoCon OT1) is
connected and correctly parametrised in the system
configuration (parameter [Outside Config] = On), – The outdoor temperature is over 8 °C, – There is no heating command, – The frost protection function is not active in any of
the conn
ected heating circuits, and
– Daikin Altherma EHS(X/H) has been switched on
for at least 5 mins.
Operating mode Reducing
Reduced heating mode (lower set room temperature) in ac­cordance with the target flow temperature
set for economy mode
in the parameter [T-Reduced] (see section 3.4.4).
Hot water generation according to the set target domestic hot water temperatures and switching cycles in the hot water time programme [DHW Program 1] (see section 3.4.5).
Operating modes Heating, Cooling
Heating or cooling operation in accordance with the room tem­perature set in the parameter [T-Room 1 Setpoint] (see section 3.4.3).
A connected outdoor temperature sensor (weather-controlled flow temperature regulation) or a connected room station will also influence the set flow temperature regulation (requirements: Parameter [HC Function] = On).
Hot water generation according to the set target domestic hot
temperatures and switching cycles in the hot water time
water programme [DHW Program 1] (see section 3.4.5).
Operating mode Summer
Hot water generation according to the set target domestic hot water temperatures and switching cycles in the hot water time programme [DHW Program 1] (see section 3.4.5).
All controllers integrated into the RoCon-system via the CAN bus are also switched at a higher level to the operating mode "Summer".
Operating mode Automatic 1 (Timer programme)
Automatic heating and economy mode in accordance with the permanent timer programmes (see section 3.4.7): – [HC Program 1] – [DHW Program 1]
Operating mode Automatic 2 (Timer programme)
Automatic heating and economy mode in accordance with the permanent timer programmes (see section 3.4.7): – [HC Program 2] – [DHW Program 2]
If, in the active operating mode, the hot water gener­ation is in setback, you can use the rotary switch to
set temporary "DHW Reheating" without having to
change any other standard settings (see section 3.4.6).
Switching contact for external operating mode switching
Via a potential-free switching contact connected to con­nection J8 of the Daikin Altherma EHS(X/H) at ter­minals "EXT" and switched with a resistance we can
so carry out a changeover of the operating mode from
al an external device (e.g. a modem, …) (see tab. 3-6).
Operating mode Resistance Tolerance
Standby < 680
Heating 1200
Reducing 1800
Summer 2700
Automatic 1 4700
Automatic 2 8200
Tab. 3-6 Resistance values for the evaluation of the EXT signal
The resistances specified in tab. 3-6 work at a toler­ance range of 5 %. Resistances outside of this toler­ance ranges are interpreted as open input. The heat generator resets to the previously active operation mode.
At resistance values higher than the value for "Automatic 2", the input is not considered.
If several switching contacts are to be connected to the
ikin Altherma EHS(X/H) (e.g. SMART GRID, Room
Da thermostat), the associ
ated functions can have a higher priority than the external operating mode switching. The operating mode requested by the EXT switching
ntact might then not be activated or may be activated
co later.
In addition to these operating modes there are various different
mporary heating programmes available (see tab. 3-7), which
te run according to priority after they have been activated.
± 5 %
Operating instructions
14
Daikin RoCon HP
Daikin Controller
008.1420844_13 – 02/2016
3 x Operation
Temporary
timer
programme
DHW Install DHW Install
Party
Away
Holiday
Setting /
activating in
level
Time Program
Rotary switch setting
Note
section
3.4.6
section
3.4.7
Vacation
Configuration >
Screed*
HC Configura-
tion
* only with expert code.
Tab. 3-7 Overview of temporary timer programmes
section
3.6.13
If a temporary timer programme (DHW Install, Party, Away, Holiday, Vacation, Screed) is started during the selected operating mode, the regulation will take place with preference according to the settings of this timer programme.

3.4.3 Temperature setting Daytime room temperature

The set room temperatures for room heating during the day are determined in the rotary switch setting
Place the rotary
switch in the "Set Temp Day" position.
.
An overview is displayed.
The end figures of the parameter designations (1 - 3) within this rotary switch setting designate the associ­ation with each individual cycle of the timer programme.
Select th
Confirm
e temperature block to be set with the rotary switch.
the changes with a brief push of the rotary switch.
Settings are displayed.
Set the
Confirm the changes with a brief push of the rotary switch.
temperature.
Change has been accepted. Jump back to previous dis-
play.
More detailed explanations and possible setting values for this rotary switch setting can be seen in chapter 6.5.

3.4.4 Temperature setting Economy mode

The set room temperatures for room heating in economy mode are determined in the rotary switch setting .
Place the rotary switch in the "Set Temp Night" position.
An overview is displayed.
Select the
Confirm the changes with a brief push of the rotary switch.
– [T-Reduced]: Set value for "Reducing" operating mode or
– [T-Absence]: Set value for temporary heating / cooling
parameter to be set with the rotary switch.
setback by a permane
nt timer programme.
programmes ("Away" and "Vacation").
Settings are displayed.
Set the
Confirm the changes with a brief push of the rotary switch.
temperature.
Change has been accepted. Jump back to previous dis-
play.
More detailed explanations and possible setting values for this rotary switch setting can be seen in chapter 6.6.

3.4.5 Temperature setting hot water generation

The hot water set temperatures for hot water generation for each individual timer programme are determined in the rotary switch setting
.
Place the rotary switch in the "DHW Set Temp" position.
The end figures of the parameter designations (1 - 3) within this rotary switch setting designate the associ­ation with each individual
cycle of the timer programme.
Select the temperature block to be set with the rotary switch.
Confirm the changes with a brief push of the rotary switch.
Settings are displayed.
Set the temperature.
Con
firm the changes with a brief push of the rotary switch.
Change has been accepted. Jump back to previous dis-
play.
More detailed explanations and possible setting values for this rotary switch setting can be seen in chapter 6.7.

3.4.6 Unscheduled hot water generation

You can charge the hot water up manually outside a hot water timer programme to the preset temperature set in parameter [T-DHW Setpoint 1] in the rotary switch position
. Heating up is carried out as a priority and independently of any other heating programmes.
Place the rotary switch in the "DHW Install" position.
An overview is displayed.
Sele
Confirm the changes with a brief push of the rotary switch.
Setting pa
Confirm the changes with a brief push of the rotary switch.
ct the parameter to be set with the rotary switch.
– [1x Hot Water]: Activating one-off hot water generation.
rameters
Begin unscheduled hot water generation.
After this temporary function has expired, the Controller automatically jumps back to the previously active oper­ating mode. The rotary switch shou
turned to the position "Info" after activation.
The function is subject to time limits.
It is interrupted at the latest after the maximum charging time set in th
e parameter [Max DHW loading ] and cannot be restarted once more until the blocking time set in the parameter [DHW Off Time] has expired (see chapter 6.2.4).
More detailed explanations and possible setting values for this rotary switch setting can be seen in chapter 6.3.
ld therefore be re-
Daikin RoCon HP Daikin Controller
008.1420844_13 – 02/2016
Operating instructions
15
3 x Operation

3.4.7 Switching time program

Various different timer programmes are available, that are set in the factory, but which can be adjusted to suit, to provide conven­ient and individual room and hot water temperature control.
The timer programmes regulate the
associated heating circuit, the storage tank charging circuit and an option connected circu­lation pump in accordance with the stipulated switching times.
Adjustment
In the rotary switch position we set the time intervals for the heating circuit, the integrated hot water generation and the optional circulation pump.
Place the rotary switch in the "Time Program"
position.
An overview is displayed.
Select the timer
Confirm the changes with a brief push of the rotary switch.
programme to be set with the rotary switch.
Settings are displayed.
Select and change the value to be set with the rotary switch.
onfirm the changes with a brief push of the rotary switch.
C
More detailed explanations and possible setting values for this rotary switch setting can be seen in chapter 6.8.
Permanent timer programmes
For the connected heating circuits and the storage tank charging circuit, timer programmes regulate the heating circuit tempera­tures or the operating times for the circulation pump in ac­cordance with the stipulated switc cycles are saved in time blocks for which various set tempera­tures apply.
In the switching cycles the heating system is regulated differen-
tiated into day and economy mode.
The target room temperatures for these timer programmes are
set in the rotary switch settings "Set Temp Day" , "Set Temp
Night"
and "DHW Set Temp 1" .
The following switching time programmes are available:
2 timer programmes for the heating circuit, each with
3 possible time cycles – [HC Program 1] – [HC Program 2]
A separate input for each individual day of the week is possible, or in blocks of "Monday to Friday", "Saturday to Sunday" and "Monday to Sunday".
Programme Time period switching cycle
HC Program 1
Single day of the week
(Monday, Tuesday ...)
hing cycles. The switching
1st
06:00 -> 22:00
.
--:-- -> --:--
2.
--:-- -> --:--
3.
Tab. 3-8 Menu structure heating circuit timer programme
Time settings for one switching cycle in one weekday or block programme are also adopted for other time pe
­riods, provided that they affect the same weekdays. Examples referring to tab. 3-8:
a) For the single working day "Monday" the start time
for the 1st switching cycle changed from 06:00 to 05:00.
In the time period "Working week" and "Entire
week", the 1st. time block switching cycle also changed from 06:00 to 05:00.
b) For the time period "Weekend", the start time for the
st switching cycle changed from 07:00 to 08:00.
1
In the individual weekdays "Saturday" and "Sun-
day", the 1st switching cycle also automatically changed from 07:00 to 08:00.
c) For the time period "Entire week", the end time in
the 1st. time block switching cycle changed from 22:00 to 21:30.
In all the weekdays the 1st switching cycle is
also changed from 22:00 to 21:30.
2 timer programmes for the hot water circuit, each with
3 possible switching cycles – [DHW Program 1] – [DHW Program 2]
The setting and input structure of the timer programmes are identical to the ones for the heating circuit timer pro­gramme (see also tab. 3-8).
1 time
Saved switching time programmes can be changed at any time. To provide a better overview, we recommend making a record of the programmed switching times and keeping it in a safe place (see chapter 9.1.1).
The permanent timer programmes are preset as per tab. 3-9.
r programme for one optionally connected circula-
tion pump with 3 individual possible switching cycles – [Circulation Time]
The setting and input structure of the timer programmes are identical to those for the heating circuit timer pro­gramme (see also tab. 3-8).
For further instructions concerning settings for an op­tional circulation pump, see section 3.6.15.
Working week
(Monday to Friday)
Weekend
(Saturday to Sunday)
Entire week
(Monday to Sunday)
HC Program 2 See HC Program 1
Operating instructions
16
1st
1st
1st
1st
.
2.
3.
.
2.
3.
.
2.
3.
.
2.
3.
06:00 -> 22:00
--:-- -> --:--
--:-- -> --:--
07:00 -> 23:00
--:-- -> --:--
--:-- -> --:--
06:00 -> 22:00
--:-- -> --:--
--:-- -> --:--
See
Program 1
HC
Daikin RoCon HP
Daikin Controller
008.1420844_13 – 02/2016
3 x Operation
Switching cycle 1 Switching cycle 2 Switching cycle 3
Time period On Off On Off On Off
Room heating / room cooling
Temperature setting
Monday - Friday 06:00 22:00 - - : - - - - : - - - - : - - - - : - -
Saturday, Sunday 07:00 23:00 - - : - - - - : - - - - : - - - - : - -
Monday - Friday 06:00 08:00 - - : - - - - : - - - - : - - - - : - -
Saturday, Sunday 07:00 23:00 - - : - - - - : - - - - : - - - - : - -
Temperature setting [T-DHW Setpoint 1]: 48 °C [T-DHW Setpoint 2]: 48 °C [T-DHW Setpoint 3]: 48 °C
Monday - Sunday 00:00 24:00 - - : - - - - : - - - - : - - - - : - -
Monday - Friday 05:00 21:00 - - : - - - - : - - - - : - - - - : - -
Saturday, Sunday 06:00 22:00 - - : - - - - : - - - - : - - - - : - -
Monday - Friday 05:00 21:00 - - : - - - - : - - - - : - - - - : - -
Saturday, Sunday 06:00 22:00 - - : - - - - : - - - - : - - - - : - -
[T-Room 1 Setpoint]: 20 °C [T-Room 2 Setpoint]: 20 °C [T-Room 3 Setpoint]: 20 °C
[T-Reduced]: 10 °C
"HC Program 1"
"HC Program 2"
domestic hot water generation
"DHW Program 1"
"DHW Program 2"
"Circulation Time"
Tab. 3-9 Factory setting for the permanent switching time programmes
Temporary timer programmes
For a specific situation there are 4 temporary programmes available, which deactivate the permanent timer programmes or the current operating mode for the duration of their validity.
The symbol of the temporary time program is displayed in the header line of the standard display, as long as the time program is active.
The following temporary time programmes may be interrupted at any time by manually changing the oper ating mode.
1.
2. [Away]: Immediate one-off setback up to 6 hours
[Party]: Immediate one-off extension of the roo m
heating
a) If an automatic programme is activated, the last
licable switching cycle is always extended. In the time
app before switching cycle 1, the target room temperature set in the parameter [T-Room 1 Setpoint] applies.
b) In all other operating modes, th
e target room temperature
set in the parameter [T-Room 1 Setpoint] applies. – The hot water generation is not affected. – The time programme runs for the set ti
me period after acti-
vation.
– The system operates in economy mode according to the
room temperature set in the rotary switch setting "Set
Temp Night"
in the parameter [T-Absence].
– The hot water generation is not affected. – The time programme runs for the set ti
me period after acti-
vation.
3.
[Holiday]: One-off calendar-controlled presence.
– The system operates exclusively in
accordance with the
"Sunday" settings in the [HC Program 1].
– The hot water generation operates exclusively in accord-
ance with the "Sunday" settings in the [DHW Program 1].
4. [Vacation]: One-off calendar-controlled reduction.
– The system only operates in econo
my mode according to
the room temperature set in the rotary switch setting "Set
-
Temp Night"
– Hot water generation according to the set temperatures
and
switching cycles in the hot water time programme
in the parameter [T-Absence].
[DHW Program 1] (see section 3.4.5).
– The calendar-controlled programme [Vacation] is no
started if the operating mode [Standby] or [Manual Oper-
ation] is active on the set start date.
t
Daikin RoCon HP Daikin Controller
008.1420844_13 – 02/2016
Operating instructions
17
3 x Operation
Remote Param
Bus - Scan
No selection
Remote Param
Bus - Scan
No selection
Remote Param
Bus - Scan
No selection
Remote Param
No selection
Contr BM1/BE1 #X
Mix Valve #X
Remote Param
Contr BM1/BE1 #X
Mix Valve #X
Remote Param
Contr BM1/BE1 #X
Mix Valve #X

3.4.8 System settings

We undertake the basic settings for the Controller RoCon HP and the system configurations for the installation environment of the Daikin Altherma EHS(X/H), the direct heating circuit, the hot
ter generation and any optionally connected components in
wa
the rotary switch setting "Configuration"
Depending on access authority (user or expe parameters are available. Certain parameters are only acces­sible to the heating expert.
LCD Display, Language, Date, Time setting
An internal pre-programmed calendar ensures auto­matic time reset at the annually recurring summer/w
inter time changes.
Place the rotary switch in the "Configuration" position.
An overview is displayed.
Select the "Setup" level with the rotary switch.
An overview is displayed.
lect the parameter [LCD Brightness] and [LCD Illum Time]
Se using the rotary switch and change if required.
se the rotary switch to select and confirm the [Language],
U [Date] or [Time] parameters.
Select and change the value to be changed within the individual display using the rotary switch.
onfirm the changes with a brief push of the rotary switch.
C
Change has been accepted. Jump back to previous dis-
play.
More detailed explanations and possible setting values for this rotary switch setting can be seen in section 3.6 and in chapter 6.2.
.
rt), various different

3.4.9 Terminal function

In the rotary switch setting "Remote Param" we can also
operate and parametrise other device bus in the RoCon system (regulating components mixer module or heat exchanger), provided that the individual component has the necessary authority (see also chapter 4.3).
After activation of the "Bus ­Scan" a list of the equipment that was recognised is shown for selection in the display (ex­ternal equipment and local equipment).
After selection and confirming
rnal device, the terminal
an exte function for this device is acti­vated and the associated standar is shown in the display.
The operating component is then in terminal mode.
d display for this device
The local control element acts as the remote control for the ex­ternal equipment. In this case a vided and saved 1:1 as on the external equipment.
The various different application and parametrisation possibilities for using the devices and operating components combined in the RoCon system are described in chapter 4.3.
Operating instructions
18
s integrated via the CAN
Fig. 3-9 Display of the level "Re-
mote Param" at commis­sioning or temporary
ection from the
disconn mains
ll the control functions are pro-
B1 Operating component RoCon B1 B1 of the
Bus CAN-Bus (connection line bet
H
1
H
2
M1 Mixer module EHS157068 U1 Room station EHS157034 WE1 Heat generator Altherma EHS(X/H)
Fig. 3-10 Example for "Bus - Scan" on a heating system with 1 heat gen-
Altherma EHS(X/H)
ween RoCon devices and operating components) Direct heating circuit (e.g. radiators) Mixed heating circuit (e.g. underfloor heating)
erator, 1 mixer, 1 room station and activation of the terminal
nction for remote control of the mixer module
fu
During this activated terminal function, the header of the display carries additional information on the remotely controlled equipment; the symbol
#X is displayed, where "X" indicates
the bus ID setting for the remotely controlled equipment.
Daikin RoCon HP
Daikin Controller
008.1420844_13 – 02/2016
3 x Operation
The displayed values and symbols are always taken over from the selected equipment (such as the mixer circuit infeed temper ature of the mixer module EHS157068 with device ID 1).
Fig. 3-11 Display example for a remotely controlled mixer module
For operation of the local equipment, this must be activated again in the selection list (parameter [No selection]).
If the message "n. A." is displayed at rotary switch set­ting terminal address.
If the message "n. A." is still displayed it may be nec­essary to update the device software before the ter­minal function can be used. Contact the Daikin Service Team in such cases.
, the control unit has yet to be assigned a valid
-
After interim isolation from the power supply, at the level "Remote Param", we always show the display as shown in
In order to be able to use the terminal function for con­nected equipment, a new Bus - Scan must be carried out.
Communication between the RoCon system compo­nents continues to function, even without a Bus - Scan, and previously made settings remain active.
Activation of the terminal function is carried out as shown in fig. 3-10, but, after confirmation of the display "Bus - Scan", you must select the parameter [New sca
fig. 3-9.
n?] with the rotary button, and confirmed with "Yes".

3.4.10 Quite Mode

Quite Mode means that the exterior heat pump unit is operating at reduced output. This reduces the operating noise caused by the exterior heat pump unit.
CAUTION!
Active Quite Mode reduces the perfor­mance in room heating and room cooling operation with the result that it may no longer be possible to reach the preset target temperatures.
Activating / deactivating normal operation
Requirement: A valid terminal ID is assigned to the RoCon B1 control element of the Daikin Altherma EHS(X/H) or the
S157034 room station.
EH
For setting the terminal address of optional connected equipment, see chapter 4.4 or the instruction handbook supplied for the respective equipment.
Place the rotary position.
switch in the "Remote Param"
The level "Remote Param" is displayed.
Select the
Confirm the changes with a brief push of the rotary switch.
parameter [Bus - Scan] with the rotary switch.
The context menu is displayed.
Use the confirm with "Yes".
rotary switch to select the parameter [Bus - Scan] and
Bus - Scan is performed.An overview of all the equipment found is displayed
(example see fig. 3-10).
Use th
Confirm
e rotary switch to select the equipment for which the
terminal function is to be performed.
the changes with a brief push of the rotary switch.
The local control element acts as the remote control for
the external equipment.
d terminal mode and restore operation of the assigned
To en equipment to the control element, at the level "Remote Param" the parameter [No selection] must be selected and acknowl­edged.
With outside temperatures below freezing, there is a risk of material damage caused by frost.
Quite Mode activation / deactivation
Place the rotary switch in the "Configuration" position.
An overview is displayed.
Sele
Se
Con
Setting pa
Con
More detailed explanations and possible setting values for this function can be seen in chapter 6.2.2.
ct the "System " level with the rotary switch.
An overview is displayed.
lect the parameter [Quite Mode] with the rotary switch.
firm the changes with a brief push of the rotary switch.
The setting for the parameter is displayed.
rameters
– Parameter [Quite Mode] = 0: deactivated – Parameter [Quite Mode] = 1: permanently activated – Parameter [Quite Mode] = 2: only activated at night
firm the changes with a brief push of the rotary switch.
Change has been accepted. Jump back to previous dis-
play.
Daikin RoCon HP Daikin Controller
008.1420844_13 – 02/2016
Operating instructions
19
3 x Operation

3.4.11 SMART GRID (SG)

WARNING!
There is a danger of scalding at target hot water temperatures over 60°C. This is possible as the electric utilities company (EVU) is entitled to control the electricity consumption optimally in accordance with supply and demand in the SMART GRID regulations.
Due to the forced charging, the target hot water temperature in the hot water storage tank can reach over 60°C.
This storage tank charging even takes place when the "Standby" operating mode it set.
Install scald protection in the hot water distribution line (e.g. VTA32,
15 60 15 + Screw connection
set 1", 15 60 16).

3.5 Special functions

In the "Special Level" we can carry out various different func-
tions that are usually used by the heating expert.
The following special functions are possible: – Manual mode (see section 3.5.1). – Message display (see section 7) – Resetting to factory settings (see section 3.6.12)
More detailed explanations of these functions can be found in chapter 6.11.
The call-up of special functions does not depend on the setting on the rotary switch.
Depress the exit button for at least 5 secs.
Menu "Special Level" is displayed.
Sele
Confirm the changes with a brief push of the rotary switch.
Can

3.5.1 Manual Operation

ct the programme to be started with the rotary switch.
The selected programme starts.
cellation and jump back by: – Pressing the exit button again, or – Briefly pressing the rotary switch or – selecting a different menu using the rotary switch.
You will need a special electric meter with an SG receiver for this function, and the Daikin Altherma EHS(X/H) must be connected to it.
As soon as the function is activated by the parameter [SMART GRID] = 1, the heat pump is moved to an operating mode in ac­cordance with tab. 3-10, depending on the signal from the energy supply company.
2)
Signal
EVU SG Hot water Heating
1 0
0 0 normal Normal operating
0 1 low The switch-on rec-
1 1 very
1) No frost-protection function (see section 3.6.5).
2) Switch contacts at input J8 of the circuit board RoCon BM1 closed (1) or open
Tab. 3-10 Utilisation of the SG signal
More detailed explanations and possible setting values for this function can be seen in chapter 6.2.1.
ed (0).
Cost of
electricity
- - -
low
Effect on
No operating
ommendation and
t value storage
se tank temperature is increased, depend-
ing on the parameter
Switch-on command and set value of stor-
age tank tempera­ture is set to 70 °C
1)
mode
mode
[Mode SG]
No operating
Normal operating
The switch-on rec-
ommendation and in-
temper creased depending
on the
Switch-on command
for stora
1)
mode
mode
flow target
ature are in-
parameter
[Mode SG]
ge tank
charging
Manual Operation is used to regulate the Daikin Altherma EHS(X/H) manually to a specific flow temperature. The manual mode should only be used for diagnostic purposes.
With hydraulically controlled priority opera
tion for the hot water generation you must make sure that the inflow target temperature set in manual mode is adequate to achieve the stored hot water set temperature (parameter [T-DHW Setpoint 1]).
Depress the exit button for at least 5 secs.
Menu "Special Level" is displayed.
Sele
Confirm the changes with a brief push of the rotary switch.
ct the programme "Manual Operation" with the rotary
switch.
"Manual Operation" active.
Set the
inflow target temperature with the rotary switch.
Do not confirm the setting with the rotary switch,
as this will close the programme.
During active manual mode the hot water is consistently
regulated to the parameter value for the first target hot water temperature ([T-DHW Setpoint 1]).
The button block (if it was activated from the start of this
function), is activated again within 2 seconds in order to prevent inadvertent termination of the function by operat­ing the Controller RoCon HP.
Cancellation and jump back by:
– Pressing the exit button again, or – Briefly pressing the rotary switch or – selecting a different menu using the rotary switch.
If the manual mode is closed, the Controller RoCon HP
automatically switches to the operating mode "Standby".