Table of contents
Table of contents
1 About this document 2
2 About the adapter 2
2.1 Basic parameters ...................................................................... 2
2.2 Compatibility.............................................................................. 2
3 About the box 2
3.1 To unpack the adapter .............................................................. 2
4 Preparation 2
4.1 Installation site requirements..................................................... 2
5 Installation 3
5.1 Precautions when installing the adapter.................................... 3
5.2 Connecting the electrical wiring................................................. 3
5.2.1 To connect the adapter with the unit........................... 3
6 Starting up the system 3
7 Hand-over to the user 3
1 About this document
Target audience
Authorised installers
Documentation set
This document is part of a documentation set. The complete set
consists of:
▪ General safety precautions
▪ Safety instructions that you must read before installing
▪ Format: Paper (in the box of the indoor unit)
▪ Installation manual:
▪ Installation instructions
▪ Format: Paper (supplied in the kit)
▪ Installer reference guide:
▪ Installation instructions, configuration, application guidelines,…
▪ Format: Digital files on http://www.daikineurope.com/support-
and-manuals/product-information/
▪ Declaration of conformity
INFORMATION: Declaration of conformity
Hereby, Daikin Europe N.V. declares that the radio
equipment type BRP069A78 is in compliance with the
Directive 2014/53/EU. The original declaration of
conformity is available from http://www.daikineurope.com/
support-and-manuals/product-information/.
Latest revisions of the supplied documentation may be available on
the regional Daikin website or via your dealer.
The original documentation is written in English. All other languages
are translations.
2.1 Basic parameters
Parameter Value
Frequency range 2400MHz~2483.5MHz
Radio protocol IEEE 802.11b/g/n
Radio frequency channel 1~13
Output power 0dBm~18dBm
Effective radiated power 17dBm (11b) / 14dBm (11g) /
13dBm (11n)
Power supply DC 3.3 V / 500 mA
2.2 Compatibility
Make sure the heat pump system is compatible for use with the
adapter. For more information, see the installer reference guide of
the heat pump system.
3 About the box
3.1 To unpack the adapter
1 Open the box.
2 Take out the adapter.
3 Separate the accessories.
a Adapter
b Installation manual
4 Preparation
4.1 Installation site requirements
▪ The adapter is designed to be mounted to the indoor unit, in dry,
indoor locations only.
▪ The adapter is designed to operate in ambient temperatures
ranging from 5~35°C.
2 About the adapter
Wireless LAN adapter to connect the heat pump system to the
Daikin Cloud via the internet, allowing for control of the heat pump
system with the Daikin Residential Controller app.
Installation manual
2
WLAN cartridge heating
BRP069A78
4P614495-1A – 2020.04