Daikin ARXM25N2V1B9 Installer reference guide [ro]

Ghidul de referință al
instalatorului
Seria R32 split
ARXM25N2V1B9 ARXM35N2V1B9
RXM20N2V1B9 RXM25N2V1B9 RXM35N2V1B9
Ghidul de referință al instalatorului
Seria R32 split
romană
Cuprins
1 Măsuri de siguranţă generale 3
1.1 Despre documentaţie ................................................................ 3
1.1.1 Explicaţia avertizărilor şi simbolurilor.......................... 3
1.2 Pentru instalator ........................................................................ 3
1.2.1 Date generale ............................................................. 3
1.2.2 Locul instalării ............................................................. 3
1.2.3 Agent frigorific............................................................. 5
1.2.4 Apa sărată................................................................... 6
1.2.5 Apă.............................................................................. 6
1.2.6 Electric ........................................................................ 6
2 Despre documentaţie 7
2.1 Despre acest document ............................................................ 7
2.2 Ghidul rapid de referinţă al instalatorului................................... 7
3 Despre cutie 7
3.1 Prezentare generală: despre cutie ............................................ 7
3.2 Unitate exterioară ...................................................................... 8
3.2.1 Pentru a despacheta unitatea exterioară.................... 8
3.2.2 Pentru a scoate accesoriile de la unitatea exterioară . 8
4 Despre unitate 8
4.1 Prezentare: Despre unitate ....................................................... 8
4.2 Identificare................................................................................. 8
4.2.1 Eticheta de identificare: Unitate exterioară ................. 9
5 Pregătirea 9
5.1 Prezentare generală: pregătirea................................................ 9
5.2 Pregătirea locului de instalare ................................................... 9
5.2.1 Cerinţele locului de instalare pentru unitatea
exterioară.................................................................... 9
5.2.2 Cerinţe suplimentare privind locul instalării unităţii
exterioare pentru zonele cu climă rece....................... 10
5.2.3 Lungimea tubulaturii de agent frigorific și diferența
de înălțime .................................................................. 11
5.3 Pregătirea tubulaturii agentului frigorific .................................... 11
5.3.1 Cerinţele agentului frigorific ........................................ 11
5.3.2 Izolarea tubulaturii de agent frigorific.......................... 11
5.4 Pregătirea cablajului electric ..................................................... 11
5.4.1 Despre pregătirea cablajului electric........................... 11
6 Instalarea 11
6.1 Prezentare generală: instalarea ................................................ 11
6.2 Deschiderea unităţii................................................................... 11
6.2.1 Despre deschiderea unității ........................................ 11
6.2.2 Pentru a deschide unitatea exterioară ........................ 12
6.3 Montarea unităţii exterioare....................................................... 12
6.3.1 Despre montarea unității exterioare............................ 12
6.3.2 Măsuri de precauție la montarea unității exterioare.... 12
6.3.3 Pregătirea structurii instalației..................................... 12
6.3.4 Instalarea unității exterioare........................................ 12
6.3.5 Asigurarea drenajului.................................................. 12
6.3.6 Pentru a preveni răsturnarea unităţii exterioare.......... 13
6.4 Conectarea tubulaturii agentului frigorific .................................. 13
6.4.1 Despre racordarea tubulaturii de agent frigorific......... 13
6.4.2 Măsuri de precauţie la racordarea tubulaturii de
agent frigorific ............................................................. 13
6.4.3 Indicații la racordarea tubulaturii de agent frigorific .... 14
6.4.4 Indicaţii privind îndoirea ţevilor.................................... 14
6.4.5 Pentru a evaza capătul ţevii........................................ 14
6.4.6 Utilizarea ventilului de închidere și ștuțului de service 15
6.4.7 Pentru a conecta tubulatura agentului frigorific la
unitatea exterioară ...................................................... 15
6.5 Verificarea tubulaturii agentului frigorific ................................... 16
6.5.1 Despre verificarea tubulaturii agentului frigorific......... 16
6.5.2 Măsuri de precauție în timpul verificării tubulaturii de
agent frigorific ............................................................. 16
6.5.3 Pentru a verifica existenţa scurgerilor.......................... 16
6.5.4 Pentru a efectua uscarea vidată .................................. 16
6.6 Încărcarea agentului frigorific ..................................................... 17
6.6.1 Despre încărcarea agentul frigorific............................. 17
6.6.2 Despre agentul frigorific............................................... 17
6.6.3 Măsuri de precauţie la încărcarea agentului frigorific .. 17
6.6.4 Pentru a stabili cantitatea de agent frigorific
suplimentar .................................................................. 17
6.6.5 Determinarea cantității totale pentru reîncărcare......... 18
6.6.6 Pentru a încărca agent frigorific suplimentar ............... 18
6.6.7 Pentru a lipi eticheta cu gaze fluorurate cu efect de
seră .............................................................................. 18
6.7 Conectarea cablajului electric .................................................... 18
6.7.1 Despre conectarea cablajului electric .......................... 18
6.7.2 Precauţii la conectarea cablajului electric.................... 18
6.7.3 Indicaţii pentru conectarea cablajului electric .............. 19
6.7.4 Specificaţii pentru componentele cablajului standard.. 19
6.7.5 Conectarea cablajului electric la unitatea exterioară ... 19
6.8 Finalizarea instalării unităţii exterioare ....................................... 20
6.8.1 Pentru a finaliza instalarea unității exterioare .............. 20
6.8.2 Pentru a închide unitatea exterioară............................ 20
6.9 Despre compresor...................................................................... 20
7 Darea în exploatare 20
7.1 Prezentare generală: Darea în exploatare ................................. 20
7.2 Măsuri de precauţie la darea în exploatare ................................ 20
7.3 Listă de verificare înaintea dării în exploatare............................ 21
7.4 Listă de verificare în timpul dării în exploatare ........................... 21
7.5 Pentru a efectua o probă de funcţionare.................................... 21
7.6 Pornirea unităţii exterioare ......................................................... 21
8 Configurare 21
8.1 Setarea pentru instalații.............................................................. 21
8.1.1 Pentru a seta modul pentru amenajări......................... 21
9 Predarea către utilizator 21 10 Întreţinere şi deservire 22
10.1 Prezentare generală: Întreţinerea şi deservirea ......................... 22
10.2 Măsuri de siguranţă pentru întreţinere ....................................... 22
10.3 Lista de verificare pentru întreţinerea anuală a unităţii
exterioare ................................................................................... 22
11 Depanarea 22
11.1 Prezentare generală: Depanarea ............................................... 22
11.2 Măsuri de precauție la depanare ................................................ 22
11.3 Rezolvarea problemelor în funcţie de simptome ........................ 22
11.3.1 Simptom: Unitățile interioare cad, vibrează sau fac
zgomot ......................................................................... 22
11.3.2 Simptom: Unitatea NU încălzeşte sau nu răceşte
conform aşteptărilor ..................................................... 23
11.3.3 Simptom: Scurgeri de apă ........................................... 23
11.3.4 Simptom: Scurgeri de electricitate ............................... 23
11.3.5 Simptom: Unitatea NU funcționează sau prezintă
deteriorări prin ardere .................................................. 23
11.4 Diagnosticarea defecţiunilor cu LED-ul de pe PCI a unităţii
exterioare ................................................................................... 23
12 Dezafectarea 23
12.1 Prezentare: Dezafectarea .......................................................... 23
12.2 Pompare pentru evacuare .......................................................... 23
12.3 Pentru a porni şi opri răcirea forţată ........................................... 24
12.3.1 Pentru a porni/opri răcirea forțată utilizând
comutatorul de cuplare/decuplare al unității
interioare...................................................................... 24
12.3.2 Pornirea/oprirea răcirii forțate utilizând interfața
utilizatorului unității interioare....................................... 24
13 Date tehnice 25
13.1 Schema de conexiuni ................................................................. 25
14 Glosar 26
Ghidul de referință al instalatorului
2
ARXM25~35N2V1B9+RXM20~35N2V1B9
Seria R32 split
4P518023-5C – 2018.09

1 Măsuri de siguranţă generale

1 Măsuri de siguranţă generale

1.1 Despre documentaţie

▪ Documentaţia originală este scrisă în limba engleză. Toate
celelalte limbi reprezintă traduceri.
▪ Precauţiile descrise în acest document acoperă subiecte foarte
importante, respectaţi-le cu atenţie.
▪ Instalarea sistemului, și toate activitățile descrise în manualul de
instalare și ghidul de referință de instalare trebuie efectuate de către un instalator autorizat.

1.1.1 Explicaţia avertizărilor şi simbolurilor

PERICOL
Indică o situaţie care duce la deces sau rănire gravă.
PERICOL: RISC DE ELECTROCUTARE
Indică o situaţie care poate duce la electrocutare.
PERICOL: RISC DE ARSURI
Indică o situaţie care poate duce la arsuri din cauza temperaturilor extrem de scăzute sau de ridicate.
PERICOL: RISC DE EXPLOZIE
Indică o situaţie care poate duce la explozie.
AVERTIZARE
Indică o situaţie care poate duce la deces sau rănire gravă.
AVERTIZARE: MATERIAL INFLAMABIL
PRECAUŢIE
Indică o situaţie care poate duce la rănirea minoră sau mai puţin gravă.
NOTIFICARE
Indică o situaţie care poate duce la distrugerea echipamentului sau bunurilor.
INFORMAŢII
Indică sfaturi utile sau informaţii suplimentare.
Simbol Explicaţie
Înainte de instalare, citiți manualul de instalare şi exploatare, și foaia cu instrucţiuni pentru cablaj.
Înainte de efectuarea lucrărilor de întreţinere şi service, citiți manualul de service.
Pentru informații suplimentare, consultați ghidul de referinţă pentru instalator și utilizator.

1.2 Pentru instalator

1.2.1 Date generale

Dacă NU sunteți sigur cum să instalaţi sau să exploataţi unitatea, contactaţi distribuitorul.
NOTIFICARE
Instalarea sau conectarea necorespunzătoare a echipamentului sau accesoriilor poate cauza electrocutare, scurtcircuit, scăpări, incendiu sau alte deteriorări ale echipamentului. Utilizaţi numai accesorii, echipament opţional şi piese de rezervă fabricate sau aprobate de Daikin.
AVERTIZARE
Asiguraţi-vă că instalarea, testarea şi materialele utilizate sunt conforme legislaţiei în vigoare (pe lângă instrucţiunile descrise în documentaţia Daikin).
PRECAUŢIE
Purtaţi echipamentul adecvat de protecţie personală (mănuşi de protecţie, ochelari de protecţie etc.) la instalarea, întreţinerea sau deservirea sistemului.
AVERTIZARE
Îndepărtaţi pungile de plastic ale ambalajului ca să nu ajungă la îndemâna altor persoane, în special a copiilor. Riscul posibil: sufocarea.
PERICOL: RISC DE ARSURI
▪ NU atingeţi tubulatura agentului frigorific, a apei sau
componentele interne în timpul funcţionării şi imediat după aceea. Aceasta poate fi foarte fierbinte sau foarte rece. Lăsaţi-o să revină la temperatura normală. Dacă trebuie să o atingeţi, purtaţi mănuşi de protecţie.
▪ NU atingeţi niciodată agentul frigorific scurs accidental.
AVERTIZARE
Luaţi măsurile necesare pentru a împiedica animalele de talie mică să se adăpostească în unitate. Animalele de talie mică care ating piesele electrice pot cauza defecţiuni, fum sau incendiu.
PRECAUŢIE
NU atingeţi priza de aer sau aripioarele din aluminiu ale unităţii.
NOTIFICARE
▪ NU puneţi niciun obiect sau echipament pe unitate. ▪ NU vă urcaţi, nu vă aşezaţi şi nu staţi pe unitate.
NOTIFICARE
Se recomandă executarea lucrărilor la unitatea exterioară când atmosfera este uscată, pentru a evita infiltraţiile.
În conformitate cu legislația în vigoare, poate fi necesară asigurarea unui registru jurnal cu produsul, conținând cel puțin: informaţii privind întreţinerea, lucrările de reparaţii, rezultatele testelor, perioadele de așteptare,…
De asemenea, TREBUIE furnizate cel puțin următoarele informații într-un loc accesibil la produs:
▪ Instrucțiuni pentru oprirea sistemului în caz de urgență ▪ Numele și adresa pompierilor, poliției și spitalului ▪ Numele, adresa și numerele de telefon de zi și de noapte pentru
service
În Europa, EN378 furnizează îndrumările necesare pentru acest registru jurnal.
ARXM25~35N2V1B9+RXM20~35N2V1B9 Seria R32 split 4P518023-5C – 2018.09

1.2.2 Locul instalării

▪ Lăsaţi spaţiu suficient în jurul unităţii pentru a permite deservirea
şi circulaţia aerului.
Ghidul de referință al instalatorului
3
1 Măsuri de siguranţă generale
Contains fluorinated greenhouse gases
2
1
1
1
2
2
kg
tCO2eq
1000
GWP × kg
=
=
+
kg
=
kg
=
GWP: xxx
R32
▪ Asiguraţi-vă că locul instalării face faţă greutăţii unităţii şi
vibraţiilor.
▪ Asiguraţi-vă că zona este bine ventilată. NU blocați orificiile de
ventilație.
▪ Asiguraţi-vă că unitatea se află pe loc drept.
NU instalaţi unitatea în următoarele locuri: ▪ În medii cu pericol de explozie. ▪ În locuri unde există instalaţii care emit unde electromagnetice.
Undele electromagnetice pot perturba sistemul de comandă, cauzând defectarea echipamentului.
▪ În locurile în care există riscul incendiilor din cauza scurgerilor
gazelor inflamabile (de exemplu: diluant sau benzină), fibre de carbon sau pulberi inflamabile.
▪ În locuri în care se produce gaz exploziv (de exemplu: gaz de acid
sulfuric). Corodarea conductelor de cupru sau a pieselor lipite poate cauza scăpări de agent frigorific.
Instrucțiuni pentru echipamentele care utilizează agent frigorific R32
Dacă este cazul.
AVERTIZARE
▪ NU perforați și nu aruncați în foc. ▪ NU folosiți mijloace de accelerare a procesului de
dezghețare sau pentru curățare, altele decât cele recomandate de fabricant.
▪ Rețineți că agentul frigorific R32 NU conține odorizant.
AVERTIZARE
Aparatul va fi păstrat astfel încât să se prevină deteriorarea mecanică, și într-o încăpere bine ventilată fără surse de aprindere cu funcționare continuă (de ex.: flacără deschisă, un aparat cu gaz în funcțiune sau un încălzitor electric în funcțiune), și având dimensiunea încăperii conform celor de mai jos.
NOTIFICARE
▪ NU reutilizaţi racordurile care au fost deja utilizate. ▪ Racordurile efectuate în instalație între piesele
sistemului de agent frigorific trebuie să fie accesibile în scopuri de întreținere.
AVERTIZARE
Dacă aparatele conțin agent frigorific R32, atunci suprafața podelei încăperii în care sunt instalate, exploatate și păstrate, TREBUIE să fie mai mare decât suprafața minimă a podelei definită în tabelul de mai jos A (m2). Aceasta se aplică la:
▪ Unități interioare fără senzor de scurgere a agentului
frigorific; în cazul unităților interioare cu senzor de scurgere a agentului de răcire, consultați manualul de instalare
▪ Unități exterioare instalate sau păstrate în interior (de
ex., grădina de iarnă, garaj, sala de mașini)
▪ Tubulatura în spațiile neventilate
Pentru a determina suprafața minimă a podelei
1 Determinați încărcătura totală de agent frigorific din sistem
(= încărcătura de agent frigorific din fabrică + cantitatea suplimentară de agent frigorific încărcat).
2 Determinați graficul sau tabelul care se utilizează.
▪ Pentru unităţile interioare: Unitatea este montată pe tavan,
montată pe perete sau instalată pe podea?
▪ Pentru unitățile exterioare instalate sau păstrate în interior, și
tubulatura de legătură în spații neventilate, acest lucru depinde de înălțimea de instalare:
Dacă înălțimea de instalare este…
Atunci utilizați graficul sau tabelul pentru…
<1,8m Unități instalate pe podea 1,8≤x<2,2m Unităţi montate pe perete ≥2,2m Unităţi montate pe tavan
3 Utilizați graficul sau tabelul pentru a determina suprafața
minimă a podelei.
AVERTIZARE
Asigurați-vă că instalarea, service+ul, întreținerea și reparațiile sunt conforme instrucțiunilor din Daikin precum și legislației în vigoare (de exemplu, reglementările naționale privind gazele) și sunt executate numai de persoane autorizate.
Cerințele spațiului de instalare
NOTIFICARE
▪ Tubulatura trebuie protejată față de deteriorarea fizică. ▪ Instalația de tubulatură trebuie menținută la minim.
Ghidul de referință al instalatorului
4
ARXM25~35N2V1B9+RXM20~35N2V1B9
Seria R32 split
4P518023-5C – 2018.09
1 Măsuri de siguranţă generale
0
10
20
30
40
50
60
70
80
90
100
110
120
130
140
150
160
170
180
190
200
210
220
230
240
250
260
270
280
290
300
310
320
330
340
350
360
370
380
390
400
410
420
430
440
450
460
470
480
490
500
510
520
530
540
550
1.822.2
2.4
2.6
2.833.2
3.4
3.6
3.844.2
4.4
4.6
4.855.2
5.4
5.6
5.866.2
6.4
6.6
6.877.2
7.4
7.6
7.8
1.843 7.956
8.0
A
min
(m2)
Floor-standing unit
(c)
Wall-mounted unit
(b)
Ceiling-mounted unit
(a)
m (kg)
Ceiling-mounted
unit
(a)
4.6 13.4
4.6 180
4.8 14.6
4.8 196
5.0 15.8
5.0 213
≤1.842
5.2 17.1
≤1.842
5.2 230
1.843 3.64
5.4 18.5
1.843 28.9
5.4 248
2.0 3.95
5.6 19.9
2.0 34.0
5.6 267
2.2 4.34
5.8 21.3
2.2 41.2
5.8 286
2.4 4.74
6.0 22.8
2.4 49.0
6.0 306
2.6 5.13
6.2 24.3
2.6 57.5
6.2 327
2.8 5.53
6.4 25.9
2.8 66.7
6.4 349
3.0 5.92
6.6 27.6
3.0 76.6
6.6 371
3.2 6.48
6.8 29.3
3.2 87.2
6.8 394
3.4 7.32
7.0 31.0
3.4 98.4
7.0 417
3.6 8.20
7.2 32.8
3.6 110
7.2 441
3.8 9.14
7.4 34.7
3.8 123
7.4 466
4.0 10.1
7.6 36.6
4.0 136
7.6 492
4.2 11.2
7.8 38.5
4.2 150
7.8 518
4.4 12.3
7.956 40.1
4.4 165
7.956 539
m (kg)
A
min
(m2)
4.6 20.0
4.8 21.8
5.0 23.6
≤1.842
5.2 25.6
1.843 4.45
5.4 27.6
2.0 4.83
5.6 29.7
2.2 5.31
5.8 31.8
2.4 5.79
6.0 34.0
2.6 6.39
6.2 36.4
2.8 7.41
6.4 38.7
3.0 8.51
6.6 41.2
3.2 9.68
6.8 43.7
3.4 10.9
7.0 46.3
3.6 12.3
7.2 49.0
3.8 13.7
7.4 51.8
4.0 15.1
7.6 54.6
4.2 16.7
7.8 57.5
4.4 18.3
7.956 59.9
Wall-mounted
unit
(b)
m (kg)
A
min
(m2)
Floor-standing
unit
(c)
m (kg)
A
min
(m2)
(c) Floor-standing unit (= unitate instalată pe podea)

1.2.3 Agent frigorific

Dacă este cazul. Consultaţi manualul de instalare sau ghidul de referinţă al instalatorului pentru aplicaţia dvs. pentru detalii suplimentare.
NOTIFICARE
Asiguraţi-vă că instalarea conductelor agentului frigorific respectă legislaţia în vigoare. În Europa, standardul în vigoare este EN378.
NOTIFICARE
Aveți grijă ca tubulatura de legătură și racordurile să NU fie tensionate.
AVERTIZARE
În timpul probelor, NU presurizaţi produsul cu o presiune mai mare decât cea maximă admisă (conform indicaţiilor de pe placa de identificare a unităţii).
AVERTIZARE
Luaţi măsuri suficiente în cazul scurgerilor agentului frigorific. Dacă există scurgeri ale agentului de răcire gazos, ventilaţi imediat zona. Riscuri posibile:
▪ Concentraţiile în exces de agent frigorific în încăperi
închise pot duce la lipsa oxigenului.
▪ Se poate produce gaz toxic dacă agentul frigorific
gazos intră în contact cu focul.
ARXM25~35N2V1B9+RXM20~35N2V1B9 Seria R32 split 4P518023-5C – 2018.09
m Încărcătura totală de agent frigorific în sistem
A
Suprafața minimă a podelei
min
(a) Ceiling-mounted unit (= unitate montată pe tavan)
(b) Wall-mounted unit (= unitate montată pe perete)
PERICOL: RISC DE EXPLOZIE Evacuare – scurgere de agent frigorific. Dacă doriți să
evacuați, și există o scurgere în circuitul agentului frigorific:
▪ NU utilizați funcţia automată de evacuare a unității, cu
care puteți colecta tot agentul frigorific din sistem în unitatea exterioară. Consecinţă posibilă: Autocombustie și explozie a compresorului din cauza aerului care pătrunde în compresorul aflat în funcțiune.
▪ Utilizați un sistem separat de recuperare, astfel încât
compresorul unității să nu trebuiască să funcționeze.
AVERTIZARE
Recuperaţi ÎNTOTDEAUNA agentul frigorific. NU eliberaţi agentul frigorific direct în atmosferă. Folosiţi o pompă de vid pentru a evacua instalaţia.
NOTIFICARE
După conectarea întregii tubulaturi, asiguraţi-vă că nu există scurgeri de gaz. Utilizaţi azot pentru a efectua detectarea scurgerii de gaz.
NOTIFICARE
▪ Pentru a evita defectarea compresorului, NU încărcați
mai mult decât cantitatea specificată de agent frigorific.
▪ Când sistemul de agent frigorific urmează să fie
deschis, agentul frigorific trebuie tratat în conformitate cu legislaţia aplicabilă.
AVERTIZARE
Asiguraţi-vă că nu există oxigen în sistem. Agentul frigorific se poate încărca numai după efectuarea testului de scurgere şi a uscării vidate.
▪ În cazul în care este necesară reîncărcarea, consultaţi placa de
identificare a unităţii. Specifică tipul de agent frigorific şi cantitatea necesară.
Ghidul de referință al instalatorului
5
1 Măsuri de siguranţă generale
▪ Unitatea este încărcată cu agent frigorific din fabrică; în funcţie de
dimensiunile şi lungimile conductelor, unele sisteme pot necesita încărcarea suplimentară cu agent frigorific.
▪ Utilizaţi numai scule exclusiv pentru tipul de agent frigorific utilizat
în acest sistem pentru a asigura rezistenţa necesară faţă de presiune şi pentru a împiedica pătrunderea materialelor străine în sistem.
▪ Încărcați agentul frigorific lichid după cum urmează:
Dacă Atunci
Există tub de sifon (respectiv, butelia este marcată
cu „Sifon atașat pentru umplerea cu lichid”)
NU există tub de sifon Încărcați cu butelia răsturnată.
▪ Deschideți încet buteliile cu agent frigorific. ▪ Încărcați agentul frigorific sub formă lichidă. Adăugarea sub formă
de gaz poate împiedica funcţionarea normală.
PRECAUŢIE
Când procedura de încărcare a agentului frigorific s-a terminat sau când este întrerupt, închideţi imediat ventilul rezervorului de agent frigorific. Dacă ventilul NU este închis imediat, presiunea rămasă ar putea încărca agent frigorific suplimentar. Consecinţă posibilă: Cantitate incorectă de agent frigorific.
Încărcați cu butelia verticală.

1.2.4 Apa sărată

Dacă este cazul. Consultaţi manualul de instalare sau ghidul de referinţă al instalatorului pentru aplicaţia dvs. pentru detalii suplimentare.
AVERTIZARE
Alegerea apei sărate TREBUIE să fie în conformitate cu legislaţia în vigoare.
AVERTIZARE
Luaţi măsuri suficiente în cazul scurgerii apei sărate. Dacă se scurge apă sărată, ventilaţi imediat zona şi contactaţi reprezentantul local.
AVERTIZARE
Temperatura ambiantă din interiorul unităţii poate fi mai ridicată decât cea din încăpere, de ex. 70°C. În cazul unei scurgeri a apei sărate, componentele fierbinţi din unitate pot duce la o situaţie periculoasă.
AVERTIZARE
Utilizarea şi instalarea aplicaţiei TREBUIE să fie conforme cu precauţiile privind siguranţa şi mediul înconjurător specificate în legislaţia în vigoare.

1.2.5 Apă

Dacă este cazul. Consultaţi manualul de instalare sau ghidul de referinţă al instalatorului pentru aplicaţia dvs. pentru detalii suplimentare.
NOTIFICARE
Asiguraţi-vă că apa are o calitate conformă cu Directiva UE 98/83CE.

1.2.6 Electric

PERICOL: RISC DE ELECTROCUTARE
▪ OPRIŢI toate sursele de alimentare înainte de a scoate
capacul cutiei de distribuţie, conecta cablurile electrice sau atinge piesele electrice.
▪ Deconectaţi reţeaua mai mult de 1 minut şi măsuraţi
tensiunea la borne a condensatoarelor circuitului principal sau a componentelor electrice înainte de deservire. Tensiunea TREBUIE să fie mai mică de 50 V c.c. înainte de a putea atinge componentele electrice. Pentru amplasarea bornelor, consultaţi
schema de conexiuni. ▪ NU atingeţi componentele electrice cu mâinile ude. ▪ NU lăsaţi unitatea nesupravegheată când este scos
capacul de deservire.
AVERTIZARE
Dacă NU este instalat din fabrică, pe cablajul fix TREBUIE instalat un întrerupător principal sau alte mijloace de deconectare, cu separarea contactelor la toţi polii, asigurând astfel deconectarea completă la supratensiune de categoria aIII-a.
AVERTIZARE
▪ Utilizaţi NUMAI cabluri din cupru. ▪ Asigurați conformitatea cablajului de legătură cu
legislația în vigoare. ▪ Întregul cablaj de legătură trebuie executat în
conformitate cu schema de conexiuni furnizată cu
produsul. ▪ Nu strângeţi NICIODATĂ mănunchiurile de cabluri şi
aveţi grijă ca acestea să NU vină în contact cu
tubulatura şi cu muchiile ascuţite. Asiguraţi-vă că pe
conexiunile de pe borne nu se aplică o presiune
externă. ▪ Asiguraţi-vă că instalaţi cablul de împământare. NU
conectaţi împământarea unităţii la o conductă de
utilităţi, la un circuit absorbant de impulsuri sau la o
linie de împământare telefonică. Legarea incompletă la
pământ poate cauza electrocutare. ▪ Aveţi grijă să folosiţi un circuit electric de alimentare
special alocat. Nu folosiţi NICIODATĂ o sursă de
alimentare în comun cu un alt aparat. ▪ Aveți grijă să instalați siguranţele sau disjunctoarele
necesare. ▪ Aveți grijă să instalați un protector pentru scurgeri la
pământ. Nerespectarea celor de mai sus poate duce la
electrocutare sau incendiu. ▪ Când instalaţi siguranţa pentru scurgerea la pământ
aveţi grijă să fie compatibil cu invertorul (rezistent la
zgomot electric de înaltă frecvenţă) pentru a evita
deschiderea inutilă a protectorului pentru scurgerea la
pământ.
Ghidul de referință al instalatorului
6
ARXM25~35N2V1B9+RXM20~35N2V1B9
Seria R32 split
4P518023-5C – 2018.09

2 Despre documentaţie

PRECAUŢIE
La conectarea cablului de alimentare de la rețea, legătura la pământ trebuie făcută înainte de stabilirea conexiunilor purtătoare de curent. La deconectarea cablului de alimentare de la rețea, conexiunile purtătoare de curent trebuie separate înainte de separarea legăturii la pământ. Lungimea conductorilor între bucla de reducere a solicitării şi regleta de conexiuni însăşi trebuie să fie stabilite astfel încât cablurile purtătoare de curent să fie strânşi înainte de cablul de legare la pământ în cazul în care cablul de alimentare de alimentare se slăbeşte din bucla de reducere a solicitării.
NOTIFICARE
Precauţii la pozarea cablajului alimentării de la reţea:
▪ Nu conectaţi cablaje de diferite secțiuni la regleta de
conexiuni a alimentării (slăbirea cablajului de alimentare poate cauza încălziri anormale).
▪ Când conectaţi cabluri de aceeaşi grosime, procedaţi
aşa cum este prezentat în figura de mai sus.
▪ Pentru cablare, utilizaţi cablul de alimentare indicat şi
conectaţi strâns, apoi fixaţi pentru a preveni exercitarea unei presiuni exterioare asupra plăcii de borne.
▪ Utilizaţi o şurubelniţă corespunzătoare pentru
strângerea şuruburilor bornelor. O şurubelniţă cu cap mic va deforma capul, făcând imposibilă strângerea corespunzătoare.
▪ Strângerea exagerată a şuruburilor bornelor le poate
rupe.
AVERTIZARE
▪ După finalizarea lucrărilor electrice, confirmaţi că
fiecare componentă şi bornă electrică din interiorul cutiei de componente electrice este bine conectată.
▪ Asiguraţi-vă că sunt închise toate capacele înainte de a
porni unitatea.
NOTIFICARE
Valabil numai dacă alimentarea electrică este trifazată şi compresorul are o metodă de pornire de tip PORNIRE/ OPRIRE.
Dacă există posibilitatea fazelor inversate după o întrerupere de moment a alimentării în timpul funcţionării produsului, montaţi pe plan local un circuit de protecţie la inversarea fazelor. Funcţionarea produsului cu faze inversate poate duce la defectarea compresorului şi a altor componente.
2 Despre documentaţie
Set documentaţie
Acest document face parte din setul documentaţiei. Setul complet este format din:
Măsuri generale de precauție:
▪ Instrucţiuni de tehnica securităţii pe care TREBUIE să le citiți
înainte de instalare
▪ Format: Hârtie (în cutia unităţii exterioare)
Manualul de instalare al unităţii exterioare:
▪ Instrucţiuni de instalare ▪ Format: Hârtie (în cutia unităţii exterioare)
Ghidul de referinţă al instalatorului:
▪ Pregătirea instalației, date de referință,… ▪ Format: Fișiere digitale la http://www.daikineurope.com/support-
and-manuals/product-information/
Cele mai recente versiuni ale documentaţiei furnizate pot fi disponibile pe site-ul Web Daikin regional sau prin intermediul distribuitorului.
Documentaţia originală este scrisă în limba engleză. Toate celelalte limbi reprezintă traduceri.
Manual de date tehnice
▪ Un subset al celor mai recente date tehnice este disponibil pe
site-ul Daikin regional (accesibil publicului).
Setul complet al celor mai recente date tehnice este disponibil pe
extranet Daikin (se cere autentificare).

2.2 Ghidul rapid de referinţă al instalatorului

Capitol Descriere
Măsuri generale de protecție
Despre documentaţie Ce documentaţie există pentru
Despre cutie Despachetarea unităților și scoaterea
Despre unitate Identificarea unității Pregătirea Ce este de făcut și de știut înainte de a
Instalarea Ce este de făcut și de știut pentru a
Darea în exploatare Ce este de făcut și de știut pentru a da
Predarea către utilizator Ce trebuie predat și explicat
Întreţinere şi service Întreținerea și deservirea unităților Depanarea Ce este de făcut în cazul unor probleme Dezafectarea Cum se dezafectează sistemul Date tehnice Specificațiile sistemului Glosar Definiţia termenilor
Instrucţiuni de tehnica securităţii pe care TREBUIE să le citiți înainte de instalare
instalator
accesoriilor
merge la fața locului
instala sistemul
în exploatare sistemul după configurare
utilizatorului

2.1 Despre acest document

INFORMAŢII
Asiguraţi-vă că utilizatorul are documentaţia tipărită şi rugaţi-l să o păstreze pentru consultare ulterioară.
Public ţintă
Instalatori autorizaţi
ARXM25~35N2V1B9+RXM20~35N2V1B9 Seria R32 split 4P518023-5C – 2018.09

3 Despre cutie

3.1 Prezentare generală: despre cutie

Acest capitol descrie ce trebuie să faceți după livrarea cutiei cu unitatea exterioară.
Reţineţi următoarele:
Ghidul de referință al instalatorului
7

4 Despre unitate

1
2
b ec da f
▪ La livrare, unitatea TREBUIE verificată să nu fie deteriorată. Orice
defecțiune TREBUIE să fie raportată imediat agentului de reclamații al transportatorului.
▪ Aduceţi unitatea împachetată cât mai aproape de locul final de
instalare pentru a preveni deteriorarea în timpul transportului.
▪ La manipularea unităţii, ţineţi cont de următoarele:
Fragil, manipulaţi unitatea cu grijă.
Menţineţi unitatea în poziţie verticală pentru a evita deteriorarea.
▪ Pregătiți în prealabil traseul pe care doriți să aduceți unitatea în
interior.

3.2 Unitate exterioară

3.2.1 Pentru a despacheta unitatea exterioară

PRECAUŢIE
Manipulați unitatea exterioară numai după cum urmează:
2 Scoateți accesoriile de pe fundul pachetului.
a Măsuri generale de protecție b Manualul de instalare al unității exterioare c Etichetă de gaz fluorurat cu efect de seră d Etichetă de gaz fluorurat cu efect de seră în mai multe limbi e Dopul de evacuare (plasat la fundul cutiei)
f Etichetă energetică
4 Despre unitate
AVERTIZARE: MATERIAL INFLAMABIL
Agentul frigorific din interiorul acestei unități este ușor inflamabil.

4.1 Prezentare: Despre unitate

Acest capitolul conține informații despre: ▪ Identificarea unităţii exterioare

4.2 Identificare

NOTIFICARE
La instalarea şi deservirea simultană a mai multor unităţi, asiguraţi-vă că NU schimbaţi între ele panourile de deservire ale unor modele diferite.

3.2.2 Pentru a scoate accesoriile de la unitatea exterioară

1 Ridicați unitatea exterioară.
Ghidul de referință al instalatorului
8
ARXM25~35N2V1B9+RXM20~35N2V1B9
Seria R32 split
4P518023-5C – 2018.09

5 Pregătirea

>150
>50
>300
(mm)
b
a
>100
>50
>150
>50
b
b
a
>100
b
a
a
b
a
>100

4.2.1 Eticheta de identificare: Unitate exterioară

Loc
5 Pregătirea

5.1 Prezentare generală: pregătirea

Acest capitol descrie ce aveţi de făcut și știut înainte de a merge la fața locului.
El conţine informații despre: ▪ Pregătirea locului de instalare ▪ Pregătirea tubulaturii de agent frigorific ▪ Pregătirea cablajului electric
AVERTIZARE
NU plasați obiecte care se pot uda sub unitatea interioară și/sau exterioară. În caz contrar, condensul de pe unitatea sau conductele de agent frigorific, murdăria filtrului de aer sau blocarea evacuării pot cauza scurgeri iar obiectele de sub unitate se pot murdări sau deteriora.
AVERTIZARE
Aparatul trebuie depozitat într-o încăpere fără surse de aprindere cu funcționare continuă (de exemplu: flacără deschisă, aparat cu gaz în funcțiune sau încălzitor electric în funcțiune).

5.2.1 Cerinţele locului de instalare pentru unitatea exterioară

INFORMAŢII
Citiţi şi cerinţele următoare:
▪ Cerinţe generale privind amplasarea. Consultaţi
capitolul “Măsuri de siguranţă generale”.
▪ Cerinţele tubulaturii agentului frigorific (diferenţă de
înălţime, lungime). Vedeţi mai departe în capitolul “Pregătirea”.
Ţineţi cont de indicaţiile următoare privind spaţiul:

5.2 Pregătirea locului de instalare

Nu instalaţi unitatea în locuri utilizate frecvent ca loc de muncă. În cazul lucrărilor de construcţie (de ex. lucrări de polizare) unde se formează mult praf, unitatea trebuie acoperită.
Alegeţi locul instalării astfel încât să existe spaţiu suficient pentru transportul unităţii la/de la locul instalării.
PRECAUŢIE
▪ Verificați dacă locul de instalare poate susține
greutatea unității. Instalarea necorespunzătoare este periculoasă. Ea poate cauza de asemenea vibrații sau
zgomote de funcționare neobișnuite. ▪ Asigurați un spațiu suficient de service. ▪ NU instalați unitatea astfel încât să fie în contact cu un
tavan sau un perete, acest lucru putând cauza vibrații.
▪ Alegeţi un loc în care aerul cald/rece evacuat din unitate sau
zgomotul funcţionării NU deranjează pe nimeni.
▪ Lăsaţi spaţiu suficient în jurul unităţii pentru a permite deservirea
şi circulaţia aerului. ▪ Evitaţi zonele în care pot exista gaze sau produse inflamabile. Instalaţi cablurile de alimentare la cel puţin 1metru de televizoare
sau aparate radio pentru a preveni interferenţa. În funcţie de undele radio, distanţa de 3metru poate să NU fie suficientă.
a Evacuarea aerului b Admisie aer
NOTIFICARE
Înălțimea peretelui de pe partea de evacuare a unității exterioare TREBUIE să fie ≤1200mm.
NOTIFICARE
▪ NU stivuiţi unităţile una peste alta. ▪ NU agăţaţi unitatea de tavan.
Vânturile puternice (≥18 km/h) care suflă în direcția orificiului de evacuare a aerului provoacă scurtcircuit (aspirarea aerului evacuat). Acest lucru poate cauza:
▪ deteriorarea capacităţii de funcţionare; ▪ formarea frecventă de gheaţă în timpul operaţiunii de încălzire; ▪ întreruperea funcţionării din cauza scăderii presiunii joase sau
creșterii presiunii înalte;
▪ distrugerea ventilatorului (dacă împotriva ventilatorului bate
constant un vânt puternic, acesta se poate roti foarte repede, până când se defectează).
Vă recomandăm să montaţi un panou deflector dacă orificiul de evacuare a aerului este expusă vântului.
ARXM25~35N2V1B9+RXM20~35N2V1B9 Seria R32 split 4P518023-5C – 2018.09