Dahua SD6CE series Installation Manual

Page 1
IR Intelligent Speed Dome
Installation Manual
Version 1.0.0
Page 2
i
Table of Contents
1 INSTALLATION PREPARATION ........................................................................ 1
1.1 Basic Requirement ................................................................................................................................ 1
1.2 Installation Check .................................................................................................................................. 1
1.3 Cable Preparation .................................................................................................................................. 1
1.3.1 The Min Specification Requirements of Cable ............................................................................. 1
1.3.2 Select Power Supply Cable ............................................................................................................. 2
2 DEVICE INSTALLATION .................................................................................... 3
2.1 Check Accessories ................................................................................................................................ 3
2.2 Open Device ........................................................................................................................................... 3
2.3 DIP Switch Setup ................................................................................................................................... 4
2.3.1 DIP Switch Location and Function ................................................................................................. 4
2.3.2 DIP Switch Setup .............................................................................................................................. 4
2.3.3 Address Setup ................................................................................................................................... 4
2.3.4 Baud Rate and Parity Setup ............................................................................................................ 5
2.3.5 Terminal Matched Resistance Setup ............................................................................................. 6
2.4 Reset Button Location and Micro SD Card Slot Installation ............................................................ 8
2.4.1 Use Reset Button .............................................................................................................................. 8
2.4.2 Install Micro SD Card ....................................................................................................................... 8
2.5 Camera Cable ........................................................................................................................................ 9
2.5.1 Cable Description .............................................................................................................................. 9
2.5.2 Cable Connection ........................................................................................................................... 10
2.5.3 Alarm Cable Connection ................................................................................................................ 10
2.5.4 Connect Camera GND Cable........................................................................................................ 10
Page 3
ii
3 WALL-MOUNT INSTALLATION........................................................................ 11
3.1 Installation Component and Dimension ........................................................................................... 11
3.2 Wall-Mounted Installation Steps ........................................................................................................ 11
3.2.1 Installation Conditions .................................................................................................................... 11
3.2.2 Installation Steps ............................................................................................................................. 12
4 HANG-MOUNT INSTALLATION ....................................................................... 15
4.1 Installation Component and Dimension ........................................................................................... 15
4.2 Hang-mounted Bracket Installation Steps ....................................................................................... 15
4.2.1 Installation Conditions .................................................................................................................... 15
4.2.2 Installation Steps ............................................................................................................................. 16
5 APPENDIX LIGHTNING PROOF AND SURGE PROTECTION (OUTDOORS)
19
5.1 Lightning Protection (Indoors) ............................................................................................................ 19
6 APPENDIX ABOUT RS485 BUS ................................................................... 21
6.1 RS485 Bus Main Feature ................................................................................................................... 21
6.2 RS485 Bus Transmission Distance .................................................................................................. 21
6.3 The Problem in Practical Use ............................................................................................................ 21
6.4 RS485 Bus FAQ .................................................................................................................................. 22
Page 4
iii
7 APPENDIX THE RELATIONSHIP BETWEEN AC 24V CABLE DIAMETER
AND TRANSMISSION DISTANCE .......................................................................... 23
8 APPENDIX THE RELATIONSHIP BETWEEN DC 12V CABLE DIAMETER
AND TRANSMISSION DISTANCE .......................................................................... 24
9 APPENDIX WIRE GAUGE REFERENCE SHEET ........................................ 26
Page 5
iv
Welcome
Thank you for purchasing our speed dome! Please read the following safeguards and warnings carefully before you install or use the product!
Page 6
v
Important Safeguards and Warnings Safety Measures
1. Qualified Engineer Needed
The installation engineer or maintenance engineer shall have corresponding CCTV system
installation certificate or maintenance qualification certificate.
The installation engineer or maintenance engineer shall have qualification certificate for work
at height.
The installation engineer or maintenance engineer shall have the basic knowledge and
operation technique for low-voltage cable layout and low-voltage electronic cable connection.
Please read the installation manual carefully and keep it well for future reference,
We are not liable for any problems caused by unauthorized modifications or attempted repair.
2. Lifting Appliance Requirement
Please select the proper speed dome installation mode and use the lifting appliances at the
safety environment.
The lifting appliances shall have the enough capacity to reach the installation height.
The lifting appliances shall have safe performance.
The precaution measures include two types: Warning and Note.
Warning: It is to alert you there is an optional risk of death or series injury!  Note: It is to alert you there is an optional risk of damage or property loss!
Warning
1. All installation and operation here should conform to your local electrical safety codes. We assume no liability or responsibility for all the fires or electrical shock caused by improper handling or installation.
2. Do not connect several speed domes to one power adapter. It may result in overheat or fire if it exceeds the rated load.
3. Before you connect the cable, install or uninstall, or begin the daily maintenance work, please turn off the power and unplug the power cable.
4. Please make sure the product is secured firmly on the wall or the ceiling.
5. Please turn off the power and unplug the power cable, If there is any smoke, disgusting smell, or noise. Please contact your local retailer or customer service center for help.
Page 7
vi
6. All the examination and repair work should be done by the qualified service engineers. We are not liable for any problems caused by unauthorized modifications or attempted repair.
Note
1. Safety Transportation
Heavy stress, violent vibration or water splash are not allowed during transportation, storage
and installation.
This series product must use split type package during the transportation.
We are not liable for any damage or problem resulting from the integrated package during
the transportation.
2. When device is malfunction
Shut down the device and disconnect the power cable immediately if there is smoke, abnormal smell or abnormal function. Please contact your local retailer ASAP.
3. Do not try to dismantle or modify the device
There is risk of personal injury or device damage resulting from opening the shell. Please contact your local retailer if there is internal setup or maintenance requirement.
We are not liable for any problems caused by unauthorized modifications or attempted repair.
4. Do not allow other object falling into the device
Please make sure there is no metal or inflammable, explosive substance in the speed dome. The above mentioned objects in the device may result in fire, short-circuit or damage. Please shut down the device and disconnect the power cable if there is water or liquid falling
into the camera. Please contact your local retailer ASAP.
Please pay attention to the camera. Avoid the sea water or rain to erode the camera.
5. Handle carefully
Do not allow this series product fall down to the ground. Avoid heavy vibration.
6. Installation Environment Requirement
This series speed dome should be installed in a cool, dry place away from direct sunlight,
inflammable, explosive substances and etc.
This series product shall be away from the strong electromagnetism radiant, please keep it
away from wireless power, TV transmitter, transformer and etc.
7. Daily Maintenance
Please use the soft cloth to clean dust on the shell, or you can use soft cloth with cleaning
liquid to clean the shell and then use soft cloth to make it dry.
Page 8
vii
Do not use gasoline, dope thinner or other chemical material to clean the shell. It may result
in shell transfiguration or paint flake.
Do not allow the plastic or rubber material to touch the shell for a long time. It may result in
paint flake.
It is highly recommended to use the product with a lightning-proof device, which can realize
better lightning-proof effect.
Page 9
1
1 Installation Preparation
1.1 Basic Requirement
All installation and operation here should conform to your local electrical safety code, fire
protection regulations and other relevant regulations.
Make sure the application scene of the camera meets the installation requirements. Please
contact dealer if you have any confusions.
Please use the product according to the operating environment. Please keep the original packing materials properly after opening the package. Please pack
the camera with original packing materials and send it back for maintenance if anything happens to the product.
1.2 Installation Check
Please make sure the installation environment has enough space to install the product and
its mounting structure components.
Please make sure the ceiling or wall can sustain 8X weight of the camera and corresponding
mounting structure components.
Please make sure the wall is thick enough to install expansion bolts (users need to prepare
by themselves).
It needs to pay attention that the installation height is required to be more than 6m if it is an
intelligent tracking device or laser speed dome.
1.3 Cable Preparation
Please select the min specification requirement of cable and video coaxial cable according to the transmission distance.
1.3.1 The Min Specification Requirements of Cable
75 ohm impedance. Full cable with copper conductor 95% knitted copper shield RS485 communication cable, refer to appendix 2 for more details.
Note
The following table can be applied to analog speed dome and network speed dome.
International Model
Max Distance (Ft\M)
RG59/U
750ft (229m)
RG6/U
1,000ft (305m)
RG11/U
1,500ft (457m)
Table 1-1
Note
The following table can be applied to HDCVI speed dome.
Page 10
2
International Model
Max Transmission Distance (Ft/M)
SYV-75-3
720P25fps/30fps):1,640ft/500m
720P50fps/60fps):984ft/300m
1080P25fps/30fps):984ft/300m
Table 1-2
1.3.2 Select Power Supply Cable
Refer to “Appendix 3 AC 24V Cable Diameter and Transmission Distance for AC 24V power supply device. Refer to “Appendix 4 DC 12V Cable Diameter and Transmission Distance for DC 12V power supply device.
Page 11
3
2 Device Installation
2.1 Check Accessories
Before installation, please check the accessories one by one according to the packing list. Please make sure all the components listed are includes.
2.2 Open Device
Please open the box and then take out the device, the device appearance is shown in Figure 2-1.
Figure 2-1
Both CVI speed dome and network speed dome have the same appearance, but the internal structure differs from each other. Please select the corresponding chapter to refer to according to the device you have purchased. CVI speed dome: Please refer to 2.3 DIP Switch Setup (Only for the reference of CVI speed
dome):
Network speed dome: Please refer to 2.4 Reset Button Location and Micro SD Card
Installation (Only for the reference of network speed dome)
Page 12
4
2.3 DIP Switch Setup
2.3.1 DIP Switch Location and Function
Open the rear cover of the device, then you can see there is DIP switch on the ISP board which is above the camera module, which is shown in Figure 2-2. The DIP switch is used to set the parameters of address, baud rate and parity.
Note
It doesnt have to make relevant RS485 settings when the HDCVI intelligent speed dome is only using coaxial control.
Figure 2-2
2.3.2 DIP Switch Setup
It has to set the address number, baud rate, parity or HD/SD video format used by speed dome before controlling the device. The speed dome will respond to its control commands after these settings are completed.
Note
It has to cut off the power and restart the device to make new settings valid. For the speed dome with cover, it needs to take down the transparent dome cover before
setting, remove the EPE foam; it needs to install the transparent dome cover back in place after settings are completed.
The speed dome DIP switch is used to confirm address, baud rate and parity. When the switch is moved to ON as 1, then 1 is the lowest bit and 8 is the highest in the address setting dial code; 1 is the lowest bit and 4 is the highest in the setting dial code of baud rate, parity or HD/SD video format (The intelligent speed dome can self-adapt to PELCO-D, PELCO-P and industrial standard protocol, the control protocol doesnt need to be set via dial code).
2.3.3 Address Setup
Note
Page 13
5
The figure of DIP switch shown in the user manual is for reference only; please refer to the actual device for more details about the DIP switch. The speed dome can use DIP switch to set address number, encoding mode can adopt binary
coding. 1(24)8(17) is valid bit, the highest address bit is 255, please refer to Figure 2-3 for address label and refer to Table 2-1 for address bit setting.
Figure 2-3
Address
1(24)
2(23)
3(22)
4(21)
5(20)
6(19)
7(18)
8(17)
1
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
1
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
2
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
3
ON
ON
OFF
OFF
OFF
OFF
OFF
OFF
4
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
5
ON
OFF
ON
OFF
OFF
OFF
OFF
OFF
6
OFF
ON
ON
OFF
OFF
OFF
OFF
OFF
7
ON
ON
ON
OFF
OFF
OFF
OFF
OFF
8
OFF
OFF
OFF
ON
OFF
OFF
OFF
OFF
……
…………………………………………………………………
254
OFF
ON
ON
ON
ON
ON
ON
ON
255
ON
ON
ON
ON
ON
ON
ON
ON
Table 2-1
2.3.4 Baud Rate and Parity Setup
Note
The figure of DIP switch shown in the user manual is for reference only; please refer to the actual device for more details about the DIP switch. It is to set the baud rate and parity of the speed dome. 9(16) and 10(15) is setting bit of baud rate, 11(14) and 12(13) is setting bit of parity. Please refer to Figure 2-4 for label and refer to Table 2-2 and Table 2-3 for setting.
Page 14
6
Figure 2-4
9(16)
10(15)
Baud Rate
OFF
OFF
9600bps
ON
OFF
4800bps
OFF
ON
2400bps
ON
ON
1200bps
Table 2-2
11(14)
12(13)
Parity
OFF
OFF
NONE
ON
OFF
EVEN
OFF
ON
ODD
ON
ON
NONE
Table 2-3
2.3.5 Terminal Matched Resistance Setup
The jumper cap which is used to set terminal resistance is located below module ISP, which is shown in Figure 2-5.
Page 15
7
Figure 2-5
There are two connection modes of device terminal 120Ω resistance, which has already existed on the power board. Please refer to Figure 2-6 for more details.
Figure 2-6
Refer to Figure 2-11 for the default connection mode, at this moment, the jumper cap on the power board is connected to the location 2~3 of the socket and 120Ω resistance hasn’t been connected yet.
Figure 2-7
Page 16
8
It needs to plug out the jumper cap from 2~3 location when it needs to connect to 120Ω
resistance, and then connect to the location of 1~2. In this case, 120Ω resistance is connected to the circuit, which is shown in Figure 2-8.
Figure 2-8
2.4 Reset Button Location and Micro SD Card Slot Installation
Open the rear cover of the speed dome, then you can see there is reset button and Micro SD card slot on the ISP board which is above the camera module. Please refer to Figure 2-9 for more details.
Figure 2-9
2.4.1 Use Reset Button
Reset button is used to reset the network system. Open the rear cover of speed dome and long press the reset button (more than 10s) to reset the device, then all the settings will be restored to factory default.
2.4.2 Install Micro SD Card
Micro SD card is used for data storage.
Page 17
9
Make the side with metal contact of the Micro SD card face downward, (pay attention to the direction of inserting Micro SD card) insert it into the slot.
Note
Push the SD card according to the direction where the card is inserted, and the card will pop out automatically.
2.5 Camera Cable
2.5.1 Cable Description
The camera is equipped with a multi-functional combination cable by default, which includes power cable, video cable, audio cable, RS485 control cable, alarm cable, network cable, high­frequency cable and optical fiber cable etc. The cable detail is shown in Figure 2-10.
Figure 2-10
Note
Different models have different cable combinations; please refer to the actual cable combination for more details. The cable combination is the most comprehensive example shown in the figure above. It is prohibited to pull the cable to lift the speed dome when moving the device, the wrong way of carrying device is shown in Figure 2-11.
Page 18
10
Figure 2-11
2.5.2 Cable Connection
Connect cable which is pulled out of wall to the corresponding power cable, video cable, audio cable, RS-485 control cable, alarm cable, network cable, high frequency cable and optical fiber cable etc. (according to the actual requirements) of the multi-functional combination cable, and then twine the cable connector with insulated tape to make it waterproof.
Note
During actual installation, make sure the wire diameter of the cable which is to connect to
RS485 control cable can’t be too big; otherwise it will affect the control effect. Please refer to appendix 2 RS485 bus for relevant introduction.
2.5.3 Alarm Cable Connection
The alarm cable connection mode and config steps are shown as follows:
Step 1
Connect alarm input device to the ALARM IN and ALARM GND of the user cable.
Step 2
Connect alarm output device to the ALARM OUT and ALARM COM of the user cable, alarm output is the relay switch output.
Step 3
Open the device WEB interface, make corresponding settings to the alarm input and output device in “Setup > Event > Alarm Setup". The alarm input of WEB is corresponding to the alarm input of the user cable. It is to set the corresponding NO and NC output according to the high and low level signal generated by alarm input device when alarm triggers.
Step 4
Set the alarm output situation of user cable on the WEB.
2.5.4 Connect Camera GND Cable
Connect the power line YELLOW & GREEN of the combination cable to the lightning protection device, and make sure the lightning protection device is well grounded.
Page 19
11
3 Wall-Mount Installation
3.1 Installation Component and Dimension
The wall-mounted bracket is shown in Figure 3-1; refer to Figure 3-2 for bracket dimension.
Figure 3-1
Figure 3-2
3.2 Wall-Mounted Installation Steps
3.2.1 Installation Conditions
The wall-mounted speed dome can be used on hard wall structure in both indoor and outdoor environments. The wall needs to meet the following installation conditions:
Page 20
12
The wall shall be thick enough to install expansion bolts. The wall shall sustain at least 8X weight of the camera and bracket etc.
3.2.2 Installation Steps
Step 1
Take pedestal of wall-mounted bracket as template; confirm the location of threaded hole and screw. Draw the screw location on the wall and knock the expansion bolts into the screw holes.
Step 2
Pull the speed dome cable through the main body of bracket, and hang both sides of the steel wire rope on the fixing buckle of the speed dome and the fixing buckle under the bracket respectively, which is shown in Figure 3-3.
Figure 3-3
Step 3
Push the speed dome upward to make the flange enter the bracket, and use hex bolt to tighten the screws on the bracket, which is shown in Figure 3-4.
Page 21
13
Figure 3-4
Step 4
Lift the camera and bracket to the same altitude as the punch position on the wall, use screw to fix the speed dome and bracket on the wall to complete installation, which is shown in Figure 3-5.
Page 22
14
Figure 3-5
Page 23
15
4 Hang-Mount Installation
4.1 Installation Component and Dimension
The hang-mounted bracket is shown in Figure 4-1; refer to Figure 4-2 for bracket dimension.
Figure 4-1
Figure 4-2
Note
The adjustable range of bracket length is: default 200mm, optional 400mm; it only needs to replace the connection pole.
4.2 Hang-mounted Bracket Installation Steps
4.2.1 Installation Conditions
The hang-mounted speed dome can be installed on hard wall structure in both indoor and outdoor environments. The wall needs to meet the following installation conditions:
The wall shall be thick enough to install expansion bolts. The wall shall sustain at least 8X weight of the camera and bracket etc.
Page 24
16
4.2.2 Installation Steps
Step 1
As it is shown in Figure 4-3, first it needs to loosen the M4 screw on the lateral of the connection chassis to separate the connection chassis from the connection pole, and then pull the integration cable through the airproof slot at the bottom of connection chassis and make it pass through the center hole which connects to the flange and fix the connection chassis on the ceiling.
Figure 4-3
Note
It needs to paste the silica gel on the surface between the connection chassis and ceiling, and the location around cable exit to make it waterproof if the speed dome is applied in the outdoor environment.
Step 2
As it is shown in Figure 4-4, pull the cable through the connection pole, and then rotate the connection pole into the connection chassis and tighten the M4 screw firmly. Open the cable exit hole on the decoration cover and push it all the way to the bottom.
Figure 4-4
Page 25
17
Note
It needs to twine enough Teflon tape at the top screw thread of the connection pole and then rotate the connection pole into the connection chassis firmly if the speed dome is used in the outdoor environments.
Step 3
Install the quick installation connector on the connection pole, which is shown in Figure 4-5.
Figure 4-5
Step 4
Connect the speed dome cable to the cable pulled out from the connection pole, and fix the speed dome on the quick installation connector to complete installation, which is shown in Figure 4-6.
Page 26
18
Figure 4-6
Page 27
19
5 APPENDIX Ⅰ LIGHTNING PROOF AND SURGE
PROTECTION (Outdoors)
This series speed dome adopts TVS lighting protection technology. It can effectively prevent damages from various pulse signals below 6000W, such as sudden lighting and surge. While maintaining your local electrical safety code, you still need to take necessary precaution measures when installing the speed dome in the outdoor environment. The distance between the signal transmission cable and high-voltage device (or high-voltage
cable) shall be at least 50 meters.
Outdoor cable layout shall go under the penthouse if possible. For vast land, please use sealing steel tube under the land to implement cable layout and
connects one point to the earth. Open floor cable layout is forbidden.
In area of strong thunderstorm hit or near high sensitive voltage (such as near high-voltage
transformer substation), you need to install additional high-power thunder protection device or lightning rod.
The thunder protection and earth of the outdoor device and cable shall be considered in the
building whole thunder protection and conform to your local national or industry standard.
System shall adopt equal-potential wiring. The earth device shall meet anti-jamming and at
the same time conforms to your local electrical safety code. The earth device shall not short circuit to N (neutral) line of high voltage power grid or mixed with other wires. When connect the system to the earth alone, the earth resistance shall not be more than 4Ω and earth cable cross-sectional area shall be no less than 25 mm². See Figure 5-1.
Figure 5-1
5.1 Lightning Protection (Indoors)
Page 28
20
The yellow and green GND wire or GND screw of the speed dome should be reliably connected by several strands of copper wire with no less than 25mm²and indoor equipotential GND terminal. Please refer to Figure 5-2 for lightningproof installation mode.
Figure 5-2
Page 29
21
6 APPENDIX ABOUT RS485 BUS
6.1 RS485 Bus Main Feature
RS485 is semi duplex communication cable of impedance 120Ω. Its max load amount is 32 effective loads (including main control device and devices to be charged).
6.2 RS485 Bus Transmission Distance
When we take 0.56mm (24AWG) twisted-pair as communication cable, the max transmission distance (theoretically) are listed below (according to different baud rates).
In the following situations, the max transmission distance shall become shorter accordingly:
The communication cable is a little bit thin; The surrounding environment has strong electromagnetic interference; There are too much devices connected to the RS485 bus;
And vice versa, the max transmission distance shall become longer.
6.3 The Problem in Practical Use
In practical usage, we usually adopt star type connection. The terminal resistance shall connect to the furthest two devices (Such as device 1# and device 15# in Figure 6-1). But this connection way does not conform to RS485 Bus standard. When the distances between devices are too long, the signal reflection occurs and anti-jamming decreases, thus the signal reliability becomes very low. You can see speed dome is not under control or speed dome is running automatically and cannot stop.
Figure 6-1
In this situation, we recommend RS485 distributor. This device can turn star type connection into the connection that conforms to RS485 bus industry standard, which can avoid the above mentioned problems and enhance communication reliability. See Figure 6-2.
Baud Rate
Max Distance
2400 BPS
1800M
4800 BPS
1200M
9600 BPS
800M
Page 30
22
Figure 6-2
6.4 RS485 Bus FAQ
Phenomenon
Possible Reasons
Solution
Speed dome can run self­diagnosis but I cannot control it.
Host address(baud rate) and
speed dome address(baud rate) are not match;
Positive and negative end of
RS485 Bus are misconnected;
Connection cable is loose RS485 Bus connection are cut
off;
Modify host or speed dome setup Switch RS485 positive end and
negative end
Fix connection cable firmly Replace RS485 Bus.
I can control the speed dome but is not smooth
RS485 Bus connection are not
good
One RS485 bus is off The distance between host and
speed dome is too far
Parallel connected too much
speed domes.
Connect RS 485 Bus again Replace RS485 Bus Add terminal matching resistance Add RS485 distributor.
Page 31
23
7 APPENDIX THE RELATIONSHIP BETWEEN AC 24V
CABLE DIAMETER AND TRANSMISSION DISTANCE
The max transmission distance is recommended when the cable diameter is fixed and AC 24V voltage loss rate is lower than 10%. For the AC power supply devices, the max allowed voltage loss rate is 10%. For example, a device with rated power of 20W, installed 141 feet (42m) away from the transformer, the minimum wire diameter needed is 0.8000mm.
mm Feetm
w
0.8000
1.000
1.250
2.000
5
488.52 148.90
763.31 232.66
1192.67 363.53
3053.25 930.63
10
244.26 74.45
381.66 116.33
596.34 181.76
1526.62 465.31
15
162.84 49.63
254.44 77.55
397.56 121.18
1017.75 310.21
20
122.13 37.23
190.83 58.16
298.17 90.88
763.31 232.66
25
97.70 29.78
152.66 46.53
238.53 72.71
610.65 186.13
30
81.42 24.82
127.22 38.78
198.78 60.59
508.87 155.10
35
69.79 21.27
109.04 33.24
170.38 51.93
436.18 132.95
40
61.06 18.61
95.41 29.08
149.08 45.44
381.66 116.33
45
54.28 16.54
84.81 25.85
132.52 40.39
339.25 103.40
50
48.85 14.89
76.33 23.27
119.27 36.35
305.32 93.06
55
44.41 13.54
69.39 21.15
108.42 33.05
277.57 84.60
60
40.71 12.41
63.61 19.39
99.39 30.29
254.44 77.55
65
37.58 11.45
58.72 17.90
91.74 27.96
234.87 71.59
70
34.89 10.64
54.52 16.62
85.19 25.97
218.09 66.47
75
32.579.93
50.89 15.51
79.51 24.24
203.55 62.04
80
30.539.31
47.71 14.54
74.54 22.72
190.83 58.16
85
28.748.76
44.90 13.69
70.16 21.38
179.60 54.74
90
27.148.27
42.41 12.93
66.26 20.20
169.62 51.70
95
25.717.84
40.17 12.25
62.77 19.13
160.70 48.98
100
24.437.45
38.17 11.63
59.63 18.18
152.66 46.53
Page 32
24
8 APPENDIX THE RELATIONSHIP BETWEEN DC 12V
CABLE DIAMETER AND TRANSMISSION DISTANCE
The max transmission distance is recommended when the cable diameter is fixed and DC 12V voltage loss rate is lower than 10%. For the DC power supply devices, the max allowed voltage loss rate is 10%. The cables used in the following table are all copper wire (the copper resistivity
is ).
mm
Feetm w
0.8000
1.000
1.250
2.000
5
122.13 37.23
190.83 58.16
298.17 90.88
763.31 232.66
10
61.06 18.61
95.41 29.08
149.08 45.44
381.66 116.33
15
40.71 12.41
63.61 19.39
99.39 30.29
254.44 77.55
20
30.53 9.31
47.71 14.54
74.54 22.72
190.83 58.16
25
24.43 7.45
38.17 11.63
59.63 18.18
152.66 46.53
30
20.35 6.20
31.80 9.69
49.69 15.15
127.22 38.78
35
17.45 5.32
27.26 8.31
42.60 12.98
109.04 33.24
40
15.27 4.65
23.85 7.27
37.27 11.36
95.41 29.08
45
13.57 4.14
21.20 6.46
33.13 10.10
84.81 28.85
50
12.21 3.72
19.08 5.82
29.82 9.09
76.33 23.27
55
11.10 3.38
17.35 5.29
27.11 8.26
69.39 21.15
60
10.18 3.10
15.90 4.85
24.85 7.57
63.61 19.39
65
9.39 2.86
14.68 4.47
22.94 6.99
58.72 17.90
70
8.72 2.66
13.63 4.15
21.30 6.49
54.52 16.62
75
8.14 2.48
12.72 3.88
19.88 6.06
50.89 15.51
80
7.63 2.33
11.93 3.64
18.64 5.68
47.71 14.54
85
7.18 2.19
11.23 3.42
17.54 5.35
44.90 13.69
90
6.78 2.07
10.60 3.23
16.56 5.05
42.41 12.93
95
6.43
10.04
15.69
40.17
Page 33
25
mm
Feetm w
0.8000
1.000
1.250
2.000
1.96
3.06
4.78
12.25
100
6.11 1.86
9.542.91
14.91 4.54
38.17 11.63
Page 34
26
9 APPENDIX WIRE GAUGE REFERENCE SHEET
Metric bare wire
diameter
mm
AWG
SWG
Bare wire cross
section
mm2)
0.050
43
47
0.00196
0.060
42
46
0.00283
0.070
41
45
0.00385
0.080
40
44
0.00503
0.090
39
43
0.00636
0.100
38
42
0.00785
0.110
37
41
0.00950
0.130
36
39
0.01327
0.140
35 / 0.01539
0.160
34
37
0.02011
0.180
33 / 0.02545
0.200
32
35
0.03142
0.230
31 / 0.04115
0.250
30
33
0.04909
0.290
29
31
0.06605
0.330
28
30
0.08553
0.350
27
29
0.09621
0.400
26
28
0.1257
0.450
25 / 0.1602
0.560
24
24
0.2463
0.600
23
23
0.2827
0.710
22
22
0.3958
0.750
21 / 0.4417
0.800
20
21
0.5027
0.900
19
20
0.6362
1.000
18
19
0.7854
1.250
16
18
1.2266
1.500
15 / 1.7663
2.000
12
14
3.1420
2.500
/ / 4.9080
3.000
/ / 7.0683
Note
This manual is for reference only. Slight difference may be found in the user interface. All the designs and software here are subject to change without prior written notice. All trademarks and registered trademarks are the properties of their respective owners. If there is any uncertainty or controversy, please refer to the final explanation of us. Please visit our website or contact your local service engineer for more information.