Dahua SD60-***-SL Series Installation Manual

Anti-corrosion Intelligent Speed Dome
Installation Manual
Version 1.0.0
i
Table of Contents
1 INSTALLATION PREPARATION ........................................................................ 1
1.1 Basic requirements ................................................................................................................................ 1
1.2 Installation Check .................................................................................................................................. 1
1.3 Cable Requirements ............................................................................................................................. 1
1.3.1 Video Cable Requirements ............................................................................................................. 1
1.3.2 Power Supply Cable Requirements ............................................................................................... 2
2 SPEED DOME INSTALLATION .......................................................................... 3
2.1 Check Accessories ................................................................................................................................ 3
2.2 Open the Device .................................................................................................................................... 3
2.3 Dial Switch Setup................................................................................................................................... 4
2.3.1 Dial Switch Address and Function .................................................................................................. 4
2.3.2 Dial Switch Setup .............................................................................................................................. 5
2.3.3 Address Setup ................................................................................................................................... 5
2.3.4 Baud Rate, Parity Setup, HD/SD Video Mode Setup .................................................................. 6
2.3.5 Terminal Matched Resistance Setup ............................................................................................. 7
2.4 SD Card Installation (Network Speed Dome) .................................................................................... 8
2.5 Speed Dome Installation ...................................................................................................................... 8
Note: ...................................................................................................................................................................... 8
2.5.1 Cable Connection ............................................................................................................................. 8
2.5.2 Junction Box and Protection Tube Installation ........................................................................... 10
2.5.3 Install Speed Dome ........................................................................................................................ 11
3 COMPONENT DIMENSION ............................................................................. 14
ii
3.1 Junction Box ......................................................................................................................................... 14
3.2 Wall Mount Bracket ............................................................................................................................. 14
3.3 Corner Mount Bracket ......................................................................................................................... 15
3.4 Pole Mount Bracket ............................................................................................................................. 16
4 WALL MOUNT BRACKET INSTALLATION ...................................................... 18
4.1 Component Installation ....................................................................................................................... 18
4.2 Wall Mount Installation Steps ............................................................................................................ 18
4.2.1 Installation Requirements .............................................................................................................. 18
4.2.2 Installation Steps ............................................................................................................................. 18
5 CORNER MOUNT BRACKET INSTALLATION ................................................ 20
5.1 Component Installation ....................................................................................................................... 20
5.2 Corner Mount Bracket Installation Steps ......................................................................................... 20
5.2.1 Installation Requirements .............................................................................................................. 20
5.2.2 Installation Steps ............................................................................................................................. 20
6 POLE MOUNT BRACKET INSTALLATION ...................................................... 23
6.1 Component Installation ....................................................................................................................... 23
6.2 Pole Mount Bracket Installation Steps .............................................................................................. 23
6.2.1 Installation Requirements .............................................................................................................. 23
6.2.2 Installation Steps ............................................................................................................................. 23
7 APPENDIX LIGHTNING PROOF AND SURGE PROTECTION ..................... 26
iii
8 APPENDIX ABOUT RS485 BUS ................................................................... 27
8.1 RS485 Bus Main Feature ................................................................................................................... 27
8.2 RS485 Bus Transmission Distance .................................................................................................. 27
8.3 The Problem in Practical Use ............................................................................................................ 27
8.4 RS485 Bus FAQ .................................................................................................................................. 28
9 APPENDIX THE RELATIONSHIP BETWEEN THE 24V AC CABLE
DIAMETER AND THE TRANSMISSION DISTANCE ............................................... 29
10 APPENDIX THE RELATIONSHIP BETWEEN THE 12V DC CABLE
DIAMETER AND THE TRANSMISSION DISTANCE ............................................... 31
11 APPENDIX IV WIRE GAUGE REFERENCE SHEET ....................................... 33
iv
Welcome
Thank you for purchasing our speed dome!
Please read the following safeguards and warnings carefully before you install or use the product!
v
Important Safeguards and Warnings Safety Measures
1. Qualified Engineer Needed
The installation engineer or maintenance engineer shall have corresponding CCTV system
installation certificate or maintenance qualification certificate.
The installation engineer or maintenance engineer shall have qualification certificate for work
at height.
The installation engineer or maintenance engineer shall have the basic knowledge and
operation technique for low-voltage cable layout and low-voltage electronic cable connection.
Please read the installation manual carefully and keep it well for future reference,
We are not liable for any problems caused by unauthorized modifications or attempted repair.
2. Lifting Appliance Requirement
Please select the proper speed dome installation mode and use the lifting appliances at the
safety environment.
The lifting appliances shall have the enough capacity to reach the installation height.
The lifting appliances shall have safe performance.
The precaution measures include two types: Warning and Note.
Warning: It is to alert you there is an optional risk of death or series injury!  Note: It is to alert you there is an optional risk of damage or property loss!
Warning
1. All installation and operation here should conform to your local electrical safety codes. We assume no liability or responsibility for all the fires or electrical shock caused by improper handling or installation.
2. Be sure to use all the accessories (such as power adapter) recommended by manufacturer.
3. Laser light is dangerous; please do not look at it straight.
4. Do not connect several speed domes to one power adapter. It may result in overheat or fire if it exceeds the rated load.
5. Before you connect the cable, install or uninstall, or begin the daily maintenance work, please turn off the power and unplug the power cable.
6. Please make sure the produce is secure firmly on the wall or the ceiling.
vi
7. Please turn off the power and unplug the power cable, If there is any smoke, disgusting smell, or noise. Please contact your local retailer or customer service center for help.
8. All the examination and repair work should be done by the qualified service engineers. We are not liable for any problems caused by unauthorized modifications or attempted repair.
Note
1. Safety Transportation
Heavy stress, violent vibration or water splash are not allowed during transportation, storage
and installation.
This series product must use split type package during the transportation.
We are not liable for any damage or problem resulting from the integrated package during
the transportation.
2. When device is malfunction
Shut down the device and disconnect the power cable immediately if there is smoke, abnormal smell or abnormal function. Please contact your local retailer ASAP.
3. Do not try to dismantle or modify the device
There is risk of personal injury or device damage resulting from opening the shell. Please contact your local retailer if there is internal setup or maintenance requirement.
We are not liable for any problems caused by unauthorized modifications or attempted repair.
4. Do not allow other object falling into the device
Please make sure there is no metal or inflammable, explosive substance in the speed dome. The above mentioned objects in the device may result in fire, short-circuit or damage. Please shut down the device and disconnect the power cable if there is water or liquid falling
into the camera. Please contact your local retailer ASAP.
Please pay attention to the camera. Avoid the sea water or rain to erode the camera.
5. Handle carefully
Do not allow this series product fall down to the ground. Avoid heavy vibration.
6. Installation Environment Requirement
This series speed dome should be installed in a cool, dry place away from direct sunlight,
inflammable, explosive substances and etc.
This series product shall be away from the strong electromagnetism radiant, please keep it
away from wireless power, TV transmitter, transformer and etc.
7. Daily Maintenance
vii
Please use the soft cloth to clean dust on the shell, or you can use soft cloth with cleaning
liquid to clean the shell and then use soft cloth to make it dry.
Do not use gasoline, dope thinner or other chemical material to clean the shell. It may result
in shell transfiguration or paint flake.
Do not allow the plastic or rubber material to touch the shell for a long time. It may result in
paint flake.
It is highly recommended to use the product with a lightning-proof device, which can realize
better lightning-proof effect.
1
1 Installation Preparation
1.1 Basic requirements
All installation and operation here should conform to your local electrical safety codes. Before installation, please open the package and check all the components are included. Please make sure the speed dome installation environment and installation mode can meet
your requirement. If there is special requirement, please contact your local retailer for more information.
We assume no liability or responsibility for all the fires or electrical shock caused by
improper handling or installation.
1.2 Installation Check
Please make sure the installation environment has enough space to install the speed dome
and its corresponding bracket.
Please make sure the ceiling, wall and the bracket can sustain the 8X weight of the speed
dome and its installation components.
Please make sure the wall is thick enough to install expansion bolts (need to be purchased). Please notice that the installation height should be more than 6m if it is a laser speed dome.
1.3 Cable Requirements
1.3.1 Video Cable Requirements
The minimum video cable requirements are as follows:
75 ohm impedance. Full copper core cable.
95% knitted copper shield
Different types of devices use different cable models. Please refer to sheet 1-1 for the cable used by analog and network speed dome, please refer to sheet 1-2 for the cable used by HDCVI speed dome.
International Model
Max Distance (Ft\M)
RG59/U
750ft (229m)
RG6/U
1,000ft (305m)
RG11/U
1,500ft (457m)
Sheet 1-1
International Model
Max Distance (Ft\M)
SYV-75-3
720P25fps\30fps):1640ft\500m
720P50fps\60fps):984ft\300m
1080P25fps\30fps):984ft\300m
Sheet 1-2
2
1.3.2 Power Supply Cable Requirements
Refer to appendix 3 for AC 24V power supply device. Refer to appendix 4 for DC12V power supply device.
3
2 Speed Dome Installation
2.1 Check Accessories
Before the installation, please check the accessories one by one according to the packing list. Please make sure all the components are included (please refer to the packing list for more details).
2.2 Open the Device
Step 1 Please open the box and then take out the speed dome. See Figure 2-1.
Figure 2-1 Step 2 Use the screw to dismantle the bracket components, take out the filling material around the module, which is shown in Figure 2-2.
4
Figure 2-2
2.3 Dial Switch Setup
2.3.1 Dial Switch Address and Function
The corresponding functions of dial switch for both analog speed dome and HDCVI speed dome are different, which will be introduced respectively.
2.3.1.1 Analog Speed Dome
Dismantle the bracket component; you can see there are two dial switches on the PTZ mainboard. You can use them to set speed dome address, baud rate and parity. Please refer to Figure 2-3 for the dial switch address.
Figure 2-3
5
2.3.1.2 HDCVI Speed Dome
Dismantle the bracket component; you can see there are two dial switches on the PTZ mainboard. You can use them to set speed dome address, baud rate and HD/SD video mode. Please refer to Figure 2-4 for the dial switch address.
Figure 2-4
2.3.2 Dial Switch Setup
Users must set the address number, Baud rate, parity setup or HD/SD video mode which is used by the speed dome before controlling it. Only after all these settings are completed, can the speed dome respond to its control commands.
Note:
Users need to install back the transparent cover component after taking out the EPE, setting
the dial switch and drying the dust and impurity inside the device.
It has to cut off the power and reboot the device after relevant information has been set
again, which can make the new settings take effect.
There are two dial switch on the speed dome PTZ which are used to confirm the speed dome address, baud rate, parity or HD/SD vide mode. It is 1 when you set the button as ON. For address setup dial switch, 1 is the lowest bit, 8 is the highest bit; for the Baud rate, parity or HD/SD video mode setup dial switch, 1 is the lowest bit, 4 is the highest bit. (Intelligent speed dome self-adapt PELCO-D, PELCO-P, industrial standard protocol and control protocol which don’t need to be set via dial switch).
2.3.3 Address Setup
The speed dome can adopt dial switch to set address, the encode mode adopts binary system. 1 to 8 is valid bit. The highest address bit is 255; see Figure 2-5 for address label and you can refer to the sheet 2-1 for address bit setup.
Figure 2-5
Address
1 2 3 4 5 6 7
8
Loading...