Dahua Network Camera Web3.0 User Manual

Dahua Network Camera Web 3.0 Operation Manual
i
Dahua Network Camera Web3.0 Operation Manual
Zhejiang Dahua Vision Technology CO., LTD
Dahua Network Camera Web 3.0 Operation Manual
ii
Table of Contents
1 Product Overview ........................................................................................................................ 1
2 Initial Config ................................................................................................................................. 2
2.1 Device Initialization ....................................................................................................... 2
2.2 Login and Logout .......................................................................................................... 5
2.2.1 Log in WEB Interface ............................................................................................... 5
2.2.2 Logout ....................................................................................................................... 6
2.3 Reset Password ............................................................................................................ 6
3 Live ................................................................................................................................................ 9
3.1 Encode Setup ................................................................................................................ 9
3.2 System Menu ............................................................................................................... 10
3.3 Video Window Function Option ................................................................................ 10
3.4 Video Window Setup .................................................................................................. 11
3.4.1 Image Adjustment ................................................................................................... 11
3.4.2 Original Size ........................................................................................................... 12
3.4.3 Full Screen .............................................................................................................. 12
3.4.4 Width and Height Ratio .......................................................................................... 13
3.4.5 Fluency Adjustment ................................................................................................ 13
3.4.6 Rules Info ............................................................................................................... 13
3.4.7 Zoom and Focus ..................................................................................................... 13
3.4.8 Fisheye/Trigger Track ............................................................................................ 13
4 PTZ Control ................................................................................................................................ 18
4.1 Scan .............................................................................................................................. 19
4.2 Preset ............................................................................................................................ 20
4.3 Tour ............................................................................................................................... 20
4.4 Pattern .......................................................................................................................... 21
4.5 Assistant ....................................................................................................................... 22
4.6 Light/Wiper ................................................................................................................... 22
5 Playback ..................................................................................................................................... 23
5.1 Playback ....................................................................................................................... 23
5.1.1 Function of Play ...................................................................................................... 24
5.1.2 Playback File .......................................................................................................... 25
5.1.3 Playback Cut ........................................................................................................... 27
5.1.4 Record Type ........................................................................................................... 27
5.1.5 Progress Bar ............................................................................................................ 27
5.1.6 Assistant Function .................................................................................................. 28
5.2 Picture Playback ......................................................................................................... 28
5.2.1 Play ......................................................................................................................... 29
Dahua Network Camera Web 3.0 Operation Manual
iii
5.2.2 Playback File .......................................................................................................... 29
5.2.3 Snapshot Type ........................................................................................................ 31
6 Setup ........................................................................................................................................... 33
6.1 Camera ......................................................................................................................... 33
6.1.1 Conditions ............................................................................................................... 33
6.1.2 Video ...................................................................................................................... 45
6.1.3 Audio ...................................................................................................................... 57
6.2 Network ......................................................................................................................... 59
6.2.1 TCP/IP .................................................................................................................... 59
6.2.2 Connection .............................................................................................................. 62
6.2.3 PPPoE ..................................................................................................................... 64
6.2.4 DDNS ..................................................................................................................... 65
6.2.5 IP filter .................................................................................................................... 67
6.2.6 SMTP e-mail) ..................................................................................................... 67
6.2.7 UPnP ....................................................................................................................... 69
6.2.8 SNMP ..................................................................................................................... 70
6.2.9 Bonjour ................................................................................................................... 72
6.2.10 Multicast ................................................................................................................. 73
6.2.11 4G ........................................................................................................................... 73
6.2.12 WIFI ........................................................................................................................ 75
6.2.13 802.1x ..................................................................................................................... 78
6.2.14 QoS ......................................................................................................................... 79
6.2.15 HTTPs ..................................................................................................................... 80
6.3 Event ............................................................................................................................. 89
6.3.1 Video detection ....................................................................................................... 89
6.3.2 Audio Detection ...................................................................................................... 96
6.3.3 Smart Plan ............................................................................................................... 98
6.3.4 Intelligence Behavior Analytics ............................................................................. 98
6.3.5 Face Detection ...................................................................................................... 106
6.3.6 People Counting ................................................................................................... 108
6.3.7 Heat Map .............................................................................................................. 110
6.3.8 Alarm .................................................................................................................... 113
6.3.9 Abnormity ............................................................................................................. 117
6.4 Storage Management ............................................................................................... 120
6.4.1 Schedule ................................................................................................................ 120
6.4.2 Destination ............................................................................................................ 124
6.4.3 Record control ...................................................................................................... 127
6.5 System ........................................................................................................................ 127
6.5.1 General .................................................................................................................. 127
Dahua Network Camera Web 3.0 Operation Manual
iv
6.5.2 Account ................................................................................................................. 130
6.5.3 PTZ ....................................................................................................................... 133
6.5.4 Default .................................................................................................................. 134
6.5.5 Import/Export ....................................................................................................... 135
5.5.6 Remote control ........................................................................................................ 135
6.5.6 Auto Maintenance ................................................................................................. 136
6.5.7 Upgrade ................................................................................................................ 137
6.6 Information ................................................................................................................. 137
6.6.1 Version .................................................................................................................. 137
6.6.2 Log ........................................................................................................................ 138
6.6.3 Online User ........................................................................................................... 138
7 Alarm ......................................................................................................................................... 140
8 Log out ...................................................................................................................................... 142
Dahua Network Camera Web 3.0 Operation Manual
v
Important
The following functions are for reference only. Some series products may not support all the functions listed below.
Cybersecurity Recommendations
1. Change Passwords and Use Strong Passwords
The number one reason systems get “hacked” is due to having weak or default passwords. It is
recommended to change default passwords immediately and choose a strong password whenever possible. A strong password should be made up of at least 8 characters and a combination of special characters, numbers, and upper and lower case letters.
2. Update Firmware As is standard procedure in the tech-industry, we recommend keeping NVR, DVR, and IP camera firmware up-to-date to ensure the system is current with the latest security patches and fixes.
“Nice to have” recommendations to improve your network security
1. Change Passwords Regularly Regularly change the credentials to your devices to help ensure that only authorized users are able to access the system.
2. Change Default HTTP and TCP Ports:
● Change default HTTP and TCP ports for systems. These are the two ports used to communicate and
to view video feeds remotely.
● These ports can be changed to any set of numbers between 1025-65535. Avoiding the default ports reduces the risk of outsiders being able to guess which ports you are using.
3. Enable HTTPS/SSL: Set up an SSL Certificate to enable HTTPS. This will encrypt all communication between your devices and recorder.
4. Enable IP Filter: Enabling your IP filter will prevent everyone, except those with specified IP addresses, from accessing the system.
5. Change ONVIF Password:
Dahua Network Camera Web 3.0 Operation Manual
vi
On older IP Camera firmware, the ONVIF password does not change when you change the system’s
credentials. You will need to either update the camera’s firmware to the latest revision or manually
change the ONVIF password.
6. Forward Only Ports You Need:
● Only forward the HTTP and TCP ports that you need to use. Do not forward a huge range of numbers
to the device. Do not DMZ the device's IP address.
● You do not need to forward any ports for individual cameras if they are all connected to a recorder on site; just the NVR is needed.
7. Disable Auto-Login on SmartPSS: Those using SmartPSS to view their system and on a computer that is used by multiple people should disable auto-login. This adds a layer of security to prevent users without the appropriate credentials from accessing the system.
8. Use a Different Username and Password for SmartPSS: In the event that your social media, bank, email, etc. account is compromised, you would not want someone collecting those passwords and trying them out on your video surveillance system. Using a different username and password for your security system will make it more difficult for someone to guess their way into your system.
9. Limit Features of Guest Accounts: If your system is set up for multiple users, ensure that each user only has rights to features and functions they need to use to perform their job.
10. UPnP:
● UPnP will automatically try to forward ports in your router or modem. Normally this would be a good
thing. However, if your system automatically forwards the ports and you leave the credentials defaulted, you may end up with unwanted visitors.
● If you manually forwarded the HTTP and TCP ports in your router/modem, this feature should be turned off regardless. Disabling UPnP is recommended when the function is not used in real applications.
11. SNMP: Disable SNMP if you are not using it. If you are using SNMP, you should do so only temporarily, for tracing and testing purposes only.
Dahua Network Camera Web 3.0 Operation Manual
vii
12. Multicast: Multicast is used to share video streams between two recorders. Currently there are no known issues involving Multicast, but if you are not using this feature, deactivation can enhance your network security.
13. Check the Log: If you suspect that someone has gained unauthorized access to your system, you can check the system log. The system log will show you which IP addresses were used to login to your system and what was accessed.
14. Physically Lock Down the Device: Ideally, you want to prevent any unauthorized physical access to your system. The best way to achieve this is to install the recorder in a lockbox, locking server rack, or in a room that is behind a lock and key.
15. Connect IP Cameras to the PoE Ports on the Back of an NVR: Cameras connected to the PoE ports on the back of an NVR are isolated from the outside world and cannot be accessed directly.
16. Isolate NVR and IP Camera Network The network your NVR and IP camera resides on should not be the same network as your public computer network. This will prevent any visitors or unwanted guests from getting access to the same network the security system needs in order to function properly.
Electrical safety
All installation and operation should conform to your local electrical safety codes. The power source shall conform to the requirement of the Safety Extra Low Voltage (SELV)
standard, and supply power with voltage rated by DC 12 V or AC 24 V according to the Limited power Source requirement of IEC60950-1. Please note that the power supply requirement is subject to the device label.
Make sure the power supply is correct before operating the device. A readily accessible disconnect device shall be incorporated in the building installation wiring Prevent the power cable from being trampled or pressed, especially the plug, power socket and the
junction extruded from the device.
We assume no liability or responsibility for all the fires or electrical shock caused by improper
handling or installation.
Environment
Dahua Network Camera Web 3.0 Operation Manual
viii
Do not aim the device at strong light to focus, such as lamp light and sun light, otherwise it might
cause over brightness or light marks, which are not the device malfunction, and affect the longevity of Charge Coupled Device (CCD) or Complementary Metal-Oxide Semiconductor (CMOS).
Do not place the device in a damp or dusty environment, extremely hot or cold temperatures, or the
locations with strong electromagnetic radiation or unstable lighting.
Keep the camera away from water or other liquid to avoid damages to the internal components. Keep the indoor device away from rain or damp to avoid fire or lightning. Keep sound ventilation to avoid heat accumulation. Transport, use and store the device within the range of allowed humidity and temperature. Heavy stress, violent vibration or water splash are not allowed during transportation, storage and
installation.
Pack the device with standard factory packaging or the equivalent material when transporting the
device.
Dahua Network Camera Web 3.0 Operation Manual
1
1 Product Overview
The common networking mode for IPC is to connect IPC to PC via switch or router. The common network mode is shown in Figure 1-1.
Figure 1-1
Before you have access to network camera via the Internet, you need to acquire its IP address. Users can search IP address of network camera via Quick Config Tool.
Dahua Network Camera Web 3.0 Operation Manual
2
2 Initial Config
In this chapter it is to introduce the device initial config operation, which includes device initialization, login device, log out WEB interface and password reset.
2.1 Device Initialization
It needs to implement device initialization when you use the device for the first time. Here it is to take WEB operation as an example to introduce device initialization. You can also initialize device via Quick Config Tool, NVR and platform etc.
Note
In order to guarantee device safety, please keep admin login password properly after device initialization, and modify the password regularly.
Step 1
Open IE browser, input camera IP address in the address bar and click Enter. The system will display the interface of Device Initialization after it is connected successfully, which is shown in Figure 2-1.
Note
The default IP address is 192.168.1.108.
Figure 2-1
Step 2
It is to set admin login password, please refer to Table 2-1 for more details.
Dahua Network Camera Web 3.0 Operation Manual
3
Parameter
Note
User name
The default user name is admin
Password
The password ranges from 8 to 32 digitals. It can contain letters, numbers
and special characters (excluding “'”,“"”,“;”,“:”,“&”) . The password shall
contain at least two categories. Usually we recommend the strong password.
Confirm password
Email
Input an email address for reset password purpose. In case you forgot password in the future, input the security code you got on the assigned email to reset the password of admin.
Table 2-1
Step 3
Click Save. The system will display the interface of End-User License Agreement, which is shown in Figure 2-2.
Figure 2-2
Step 4
Select I have read and agree to all terms and click Next. The system will display the interface of Easy4iP, which is shown in Figure 2-3.
Dahua Network Camera Web 3.0 Operation Manual
4
Figure 2-3
Step 5
Select Easy4iP according to actual needs and realize Easy4iP registration for device, click next. The system will display the interface of Online Upgrade, which is shown in Figure 2-4
Figure 2-4
Step 6
It is to set upgrade method according to the actual requirements.
Dahua Network Camera Web 3.0 Operation Manual
5
Select Auto-check for upgrade and the system will check once daily automatically when there is system upgrade prompt.
Note
After login, you can make setting in ‘Setup > System > Upgrade > Online Upgrade’.
Step 7 Click Save and device initialization is completed.
2.2 Login and Logout
Here it is to introduce device login and WEB interface logout via browser, it is to take IE Explorer 8 as an example to make introduction.
2.2.1 Log in WEB Interface
Users can make operations such as live, playback and config upon the device after logging in device WEB interface via browser.
Note
It can log in WEB interface after device initialization is completed. It will prompt to install plug-in when logging in the system for the first time, please download and
install plug-in according to prompt.
Step 1
Open IE browser, input camera IP address in the address bar and click Enter button. The system will display the Login interface after it is successfully connected, which is shown in Figure 2-5.
Figure 2-5
Dahua Network Camera Web 3.0 Operation Manual
6
Step 2
Input the password of admin user.
Step 3
Click Login. It will display the Live interface after it logged in successfully, which is shown in Figure 2-6.
Note
Different devices have different functions with different interface display; please refer to the actual interface for more details.
Figure 2-6
2.2.2 Logout
Click Logout and return to WEB login interface. After logging in the device WEB, the system will hibernate automatically if it fails to operate the device for a period of time. It can recover to normal working status quickly after entering password.
2.3 Reset Password
Users can reset password via reserved email when you forget the password of admin user.
Step 1
Open IE browser, input camera IP address in the address bar and click Enter button. The system will display the Login interface after it is successfully connected, which is shown in Figure 2-7.
Dahua Network Camera Web 3.0 Operation Manual
7
Figure 2-7
Step 2
Click Forgot password? The system will display the interface of Reset Password, which is shown in Figure 2-8.
Figure 2-8
Step 3
Reset login password. Scan the QR code according to the interface prompt and acquire security code, then input the security code which is received via your reserved email.
Caution
Dahua Network Camera Web 3.0 Operation Manual
8
Please use the security code to reset the password within 24 hours after you received the security
code via your reserved email. Otherwise the security code will be invalid.
If you fail to use security code for twice continuously, then the system will prompt that it fails to
acquire security code for the third time. It needs hardware to restore device default setting and acquire security code again or wait for 24 hours and acquire it again if it needs to use the device normally.
Step 4
Click next. The system will display the interface where you can set the new password, which is shown in Figure 2-9.
Figure 2-9
Step 5
Reset Password and Confirm Password. The password ranges from 8 to 32 digitals. It can contain letters, numbers and special characters (excluding “'”,“"”,“;”,“:”,“&”) . The password shall contain at least two categories. Usually we recommend the strong password.
Step 6
Click Save and complete password reset. The system will display the Login interface.
Dahua Network Camera Web 3.0 Operation Manual
9
3 Live
After you logged in, you can see the live monitor window. See Figure 3-1.
Figure 3-1
There are four sections:
Section 1: Encode setup bar Section 2: System menu Section 3: Window function option bar Section 4: Window adjust bar
3.1 Encode Setup
Note: Some series don’t support sub stream 2. The encode setup interface is shown as in Figure 3-2.
Figure 3-2
Please refer to the following sheet for detailed information.
2 3 1
4
Dahua Network Camera Web 3.0 Operation Manual
10
Parameter
Function
Main stream
Click it to enable main stream video monitoring and click again to disable it. Generally for storage and monitor.
Sub Stream 1
Click it to enable Sub Stream1 video monitoring and click again to disable it. When network bandwidth is insufficient, it substitutes main stream for monitoring.
Sub Stream 2
Click it to enable Sub Stream 2 video monitoring and click again to disable it. When network bandwidth is insufficient, it substitutes main stream for monitoring.
Protocol
You can select stream media protocol from the dropdown list. There are three options: TCP/UDP/Multicast
3.2 System Menu
System menu is shown as in Figure 3-3. Please refer to chapter 2 Live, chapter 3 PTZ, chapter 4 Playback, chapter 5 Setup, chapter 6 Alarm, chapter 7 Log out for detailed information.
Figure 3-3
3.3 Video Window Function Option
The interface is shown as below. See Figure 3-4.
Figure 3-4
Please refer to the following sheet for detailed information.
SN
Parameter
Function
1
Relay-out
It shows if there is any alarm output, status description is as follows:
Red: means there is alarm output. Grey: means alarm is over.
Click on the button to force alarm to be on or off.
1 2 3 4 5 6 7 8 9
Dahua Network Camera Web 3.0 Operation Manual
11
2
Digital Zoom
When the video is in the original status, click it you can
select any zone to zoom in. In the non-original status, you can drag the zoom-in zone in specified range. Right click mouse to restore previous status.
Click it; you can use the middle button of the mouse to
zoom in/out the video size.
3
Snapshot
Click on the button to snapshot, save picture to path in Ch
5.1.2.5.
4
Triple Snapshot
Click it to take snapshot upon the video at the frequency of one picture per second. All images are saved to path in Ch
5.1.2.5.
5
Record
Click it to record the video. All videos are saved to path in Chapter 5.1.2.5.
6
Easy focus
Click it, you can see there are two parameters on the preview videoAF Peak and AF Max.
AF Peak: It is to display the video definition during the focus process.
AF Max: It is the most suitable value for the video definition. The close the AF Peak and AF Max is, the better the focus
effect is.
7
Audio
Turn on or off audio when you are monitoring.
8
Talk
Click it to start or end bidirectional talk. 9
Help
Click it to open help file.
3.4 Video Window Setup
The interface is shown as in Figure 3-5.
Figure 3-5
3.4.1 Image Adjustment
See Figure 3-6 for image adjustment.
Dahua Network Camera Web 3.0 Operation Manual
12
Figure 3-6
Click this button to display/hide image control interface. Click it to open picture setup interface. This interface is on the top right pane. Please refer to the following sheet for detailed information.
Parameter
Function
Video setup
It is to adjust monitor video brightness.
Note: All the operations here apply
to WEB end only.
Please go to Setup-
>Camera->Conditions to adjust corresponding items.
It is to adjust monitor video contrastness.
It is to adjust monitor video hue.
It is to adjust monitor video saturation.
Reset
R e
Restore brightness, contrastness saturation and hue to system default setup.
3.4.2 Original Size
Click this button to go to original size. It is to display the actual size of the video stream. It depends on the resolution of the bit stream.
3.4.3 Full Screen
Click it to go to full-screen mode. Double click the mouse or click the Esc button to exit the full screen.
Dahua Network Camera Web 3.0 Operation Manual
13
3.4.4 Width and Height Ratio
Click it to restore original ratio or suitable window.
3.4.5 Fluency Adjustment
There are three levels of fluency for you to select (Realtime, Normal, and Fluency). The default is normal.
3.4.6 Rules Info
Click the button, preview image will display intelligent rules after enabling; it is enable” by default.
3.4.7 Zoom and Focus
Click this button and the focus zooming interface appears on the right of preview interface, as shown in Figure 2-7, click left mouse button to adjust focus zooming configuration. Note:
· The product series which support motorized zoom, synchronous focus and back focus have this button.
· Auto-focus after zoom and focus adjustment.
3.4.8 Fisheye/Trigger Track
Click the button, installation mode and display mode interface will show up on the right of the preview interface, see Figure 3-7 and Figure 3-8, and single click to switch different installation modes and display modes for fisheye, or switch different display modes for trigger track, it is enabled by default.
Note:
It is only supported by some models.
Figure 3-7
Dahua Network Camera Web 3.0 Operation Manual
14
Parameter
Function
Zoom
Adjust the focal length of the lens by clicking or long pressing “+”“-”buttons. The speed is used to adjust the length of one step during single click.
Focus
Adjust the sharpness of the lens by clicking or long pressing“+”-” buttons. Step length is used to adjust the length of one step with one click.
Auto­focus
Click to adjust the image definition automatically. Note: Other lens operations are not allowed during the process of auto-focus.
Reset All
Reset the lens to zero position to eliminate the accumulative error of lens. Note: Please reset when the image adjustment is not clear or operating zoom focus many
times.
Refresh
Synchronize the location of drag slider of lens and zoom focus after hardware zoom focusing.
Regional Focus
Click it and use the mouse to select a zone, then the device can auto focus within the specific region.
In-ceiling Mount Wall Mount Ground Mount
Figure 3-8
Dahua Network Camera Web 3.0 Operation Manual
15
parameter
Note
Installation Mode
Three modes which are ceiling mount, wall mount and ground mount.
Display Mode
It represents the display mode of the current image (default supports original image mode), the display modes may be different according to different installation modes. It is shown as follows:
Ceiling: 1P+12P1+21+31+4、1P+6、1+8。 Wall: 1P1P+31P+41P+8 Ground: 1P+12P1+31+4、1P+6、1+8。
Note: The default displays original image mode when switching installation mode.
In-ceiling/Wall/Ground
Original
image
It menas the original image without de-warpping
In-ceiling/Ground
1P+1
360°expanded rectangular panorama + independent sub image, the sub image and the subbox in the expanded rectangular panorama support zoom and movement, for the expanded rectangular panorama also supports left and right starting point movement.
2P
Two related 180° expanded rectangular pictures, two subwindows form 360° panorama anytime, which is
also called “dual panorama”. Two expanded
rectangular pictures both support left and right movement starting point, which are also linked by eachother.
1+2
Original image + 2 independent sub images, both the sub image and the subbox in the original image support zoom and movement. The original image also supports changing starting point by rotation (no such display mode for ground installation).
1+3
Original image + 2 independent sub images, both the sub image and the subbox in the original image support zoom and movement. The original image also supports changing starting point by rotation
1+4
Original image + 4 independent sub images, both the sub image and the subbox in the original image support zoom and movement. The original image also supports changing starting point by rotation
1P+6
360°expanded rectangular panorama +6 independent sub image, both the sub image and the subbox in the expanded rectangular panorama support zoom and movement, for the expanded rectangular panorama also supports left and right starting point movement.
Dahua Network Camera Web 3.0 Operation Manual
16
parameter
Note
1+8
Original image + 8 independent sub images, both the sub image and the subbox in the original image support zoom and movement. The original image also supports changing starting point by rotation
Wall
1P
From left to right 180° expanded rectangular panorama, which supports up and down movement and changes vertical angle of view.
1P+3
180° expanded rectangular panorama+3 independent sub images, both the sub images and the sub box in the expanded rectangular panorama support zoom and movement, expanded rectangular panorama supports up and down movement and changes vertical angle of view.
1P+4
180° expanded rectangular panorama+4 independent sub images, both the sub images and the sub box in the expanded rectangular panorama support zoom and movement, expanded rectangular panorama supports up and down movement and changes vertical angle of view.
1P+8
180° expanded rectangular panorama+8 independent sub images, both the sub images and the sub box in the expanded rectangular panorama support zoom and movement, expanded rectangular panorama supports up and down movement and changes vertical angle of view.
Figure 3-9
Enable the trigger track on the interface of tripwire or intrusion, and draw the rule of tripwire or intrusion, the scene of trigger track window will change according to the moving object when it triggers rule alarm until the moving object disappears from the view range of the camera. Please refer to “5.3.4 IVS” for more details about the rules drawing and parameter config of tripwire and intrusion. Trigger track includes three modes which are 1P, 1P+3 and 1P+5.
1P: Original picture
Dahua Network Camera Web 3.0 Operation Manual
17
1P+3: Original picture and three trigger track windows, it can adjust the location and size of
three trigger track windows on the original picture.
1P+5: Original picture and five trigger track windows, it can adjust the location and size of
five trigger track windows on the original picture.
Dahua Network Camera Web 3.0 Operation Manual
18
4 PTZ Control
Here you can view direction keys, speed, zoom, focus, iris, preset, tour, scan, pattern, aux on, off and PTZ setup button.
Note
Before PTZ operation, please make sure you have properly set PTZ protocol. (Please refer to Ch 5.5.3). Currently only IPC-HFXXXX series and –PT series products can support PTZ function.
Parameter
Note
PTZ direction
PTZ supports eight directions: left/right/up/down/upper left/upper right/bottom left/bottom right.
Speed
It controls rotation speed. The longer the step length, the higher the speed. Step length control PTZ, zoom, focus and iris.
Quick Position
Use mouse to draw a box in monitoring video, PTZ will rotate and focus to quickly positioning.
Figure 4-1
Dahua Network Camera Web 3.0 Operation Manual
19
Figure 4-2
PTZ setting interface is shown as in Figure 4-3. Here you can set scan, preset, tour, pattern, assistant function and light and wiper plus view coordinate.
Figure 4-3
4.1 Scan
Scan interface is shown in Figure 4-4.
Dahua Network Camera Web 3.0 Operation Manual
20
Figure 4-4
Steps to scan are:
Step 1. Click on Set button, display icon. Step 2. Move via direction key to select left, click on Set Left to set left border of camera
Step 3. Move via direction key to select right, click on Set Right to set right border of camera. Step 4. Complete scan path setup.
4.2 Preset
Preset interface is shown in Figure 4-5.
Figure 4-5
Steps to preset are: Step 1. In preset box, input preset value. Step 2. Click on Go to, camera rotates to preset position. Step 3. Use direction key to rotate camera, and in preset box input preset value. Step 4. Click on Add to add a preset. Range of preset relates to PTZ protocol.
4.3 Tour
Dahua Network Camera Web 3.0 Operation Manual
21
Tour interface is shown in Figure 4-6.
Figure 4-6
Steps to tour are: Step 1. In tour box, input tour path value. Step 2. Click on Add. Range of tour relates to PTZ protocol. Step 3. In preset box, input preset value. Step 4. Click on Add as to add a preset in this tour. If click on Del, it deletes this preset in tour. Note: You can add more than one preset here, or delete more than one preset.
4.4 Pattern
Pattern interface is shown in Figure 4-7.
Figure 4-7
Steps to set pattern are shown as follows: Step 1 Input pattern serial number value in the box, click “Add” and it will display “Start Rec” and “Stop Rec”. Step 2 Click “Start Rec” to implement a series of operations such as zoom, focus, iris, direction and so on. Step 3
Dahua Network Camera Web 3.0 Operation Manual
22
Click “Stop Rec” to complete the setting of a pattern path. Step 4 Click “Start” and it will start pattern according to the pattern path which has been set; click “Stop” and the pattern ends.
4.5 Assistant
Assistant interface is shown in Figure 4-8.
Figure 4-8
Steps to assistant are: Step 1. In assistant box input assistant value. Step 2. Click on Aux On to turn on aux function.
Click on Aux off to turn off aux function.
4.6 Light/Wiper
Light wiper interface is shown in Figure 4-9.
Figure 4-9
Steps to light wiper are:
Click on Enable to enable light wiper function. Click on Disable to disable light wiper function.
Dahua Network Camera Web 3.0 Operation Manual
23
5 Playback
Web client playback supports video playback and picture playback. Note: Before playback, user shall set storage management as in Ch. 5.4.
5.1 Playback
The playback interface is shown as in Figure 5-1.
Figure 5-1
There are four sections:
Section 1: Function of play Section 2: Playback file Section 3: Play time cut Section 4: Record type Section 5: Progress bar Section 6: Assistant function
2 3 4
1 6 5
Dahua Network Camera Web 3.0 Operation Manual
24
5.1.1 Function of Play
The function of play is shown as in Figure 5-2 and Figure 5-3.
Figure 5-2
Figure 5-3
Parameter
Function
Play
When you see this button, it means pause or not played record. Click on this button, switch to normal play status.
Stop
Click this button to stop playing.
Play by frame
Click on this button to go to next frame. Note: You shall pause record when you use this function.
Slow
Click on this button to play slowly.
Quick
Click on this button to play quickly.
Silent
When this button displays, it means audio is silent. Click on this button to
switch back to normal.
Volume
Click on left mouse to adjust volume.
-1 Fisheye
Click this button and fisheye device can adjust display mode according to different installation mode during the process of playback.
-2 Rule Info
Click the button and it will playback and display intelligent rules and object detection box if the video is equipped with intelligent rule info after the function is enabled, it is off by default.
Dahua Network Camera Web 3.0 Operation Manual
25
5.1.2 Playback File
In calendar, blue date represents data currently has video record or snapshot. See Figure 5-4.
Figure 5-4
Parameter
Function
File Type
Select “dav”, as video playback. Select “jpg” as picture playback.
Data Source
Default is SD card.
Step 1. Click on data in blue, time axis displays record file progress bar in color. While, green represents
normal record, yellow represents motion detect record, red represents alarm record, and blue represents manual record.
Step 2. Click on certain time on progress bar, playback starts from this time. See Figure 5-5.
Figure 5-5
Step 3. Click on file list , select date file will be displayed in list. Step 4. Double click on file in list, playback this file and display file size, start time and end time.
See Figure 5-6.
Dahua Network Camera Web 3.0 Operation Manual
26
Figure 5-6
Parameter
Function
Search
It means records within searched start time and end time on the date.
Download Format
There are two formats: dav, mp4.
Download
click the download button and download file to path in Ch. 5.1.2.5. System does not support download and playback at the same time.
Dahua Network Camera Web 3.0 Operation Manual
27
Parameter
Function
Back
Click on back button to go to calendar interface.
5.1.3 Playback Cut
Note: Playback cut function will automatically pause playing record as playback cut and playback cannot be at the same time. Step 1. Click on start time to cut on time axis. This time must be within progress bar range.
Step 2. Move mouse to cut icon . You will be ask to select start time. Click on cur icon as
finish cutting.
Step 3. Click on playback cut end time on time axis. This time must be within progress bar range.
Step 4. Move mouse to cut icon you will be asked to select end time. Click on cut icon as
finish cutting.
Step 5. Click on Save button to save file cut to path in Ch 5.1.2.5. See Figure 5-7.
Figure 5-7
5.1.4 Record Type
After checking record file type, only selected file will be displayed in progress bar and file list. Users can also select the record type to be displayed via the dropdown box which is above the file list. See Figure
5-8.
Figure 5-8
5.1.5 Progress Bar
Figure 5-9
Dahua Network Camera Web 3.0 Operation Manual
28
Parameter
Function
24 hours
Click on it, means video in past 24 hours.
2 hours
Click on it, means video in past 2 hours.
1 hour
Click on it, means video in past 1 hour.
30 min
Click on it, means video in past 30 min.
5.1.6 Assistant Function
Video playback assistant function is shown in Figure 5-10.
Figure 5-10
Parameter
Function
Digital Zoom
Click on it, video in playback status if is in original size, user can
zoom in any area, If it is not in its original size, Right mouse click to restore its original size.
Click on this button, you can scroll to zoom in.
Snapshot
Click on this button, you can snapshot video under playback status. Snapshot will be saved to path in Ch. 5.1.2.5.
5.2 Picture Playback
Web client picture playback interface has the following three functions:
Parameter
Function
1
Play function bar
2
Playback file bar
3
Snapshot type bar
See Figure 5-11.
Dahua Network Camera Web 3.0 Operation Manual
29
Figure 5-11
5.2.1 Play
Figure 5-12
Default icon is and it means pause or not played picture. Click on play button to switch to
normal play status. Icon become Click on it to pause.
5.2.2 Playback File
Dahua Network Camera Web 3.0 Operation Manual
30
Figure 5-13
Step 1. Click on file list , select snapshot file of the date. Step 2. Double click on file in list, to play this snapshot.
Parameter
Function
Search
It means all snapshot files within the start time and end time of selected date.
Dahua Network Camera Web 3.0 Operation Manual
31
Parameter
Function
Download
Click the download button to open snapshot file or directly download to local according to the browser types.
Back
Click the back button to return to calendar interface and re-select time.
Figure 5-14
5.2.3 Snapshot Type
Dahua Network Camera Web 3.0 Operation Manual
32
After checking snapshot file type, in file list only display file of selected type. Users can also select the snapshot type to be displayed via the dropdown box above the file list. See Figure 5-15.
Figure 5-15
Dahua Network Camera Web 3.0 Operation Manual
33
6 Setup
Web client setup support camera, network, time, storage, system and system info view.
6.1 Camera
The camera setting includes conditions, profile management, zoom and focus.
6.1.1 Conditions
Note:
The camera parameter may be different according to different models, please refer to the actual product for more details.
6.1.1.1 Picture
Note:
The device which supports true WDR fails to support long exposure when true WDR is enabled. Step 1
Select “Setup > Camera > Conditions > Picture” and the system will display the “Picture” image which is
shown in Figure 6-1.
Figure 6-1
Step 2 Set picture parameters; please refer to the following sheet for more details about parameter setting.
Parameter
Note
Style
It is to set the picture style, which includes standard, soft and vivid.
Dahua Network Camera Web 3.0 Operation Manual
34
Parameter
Note
Brightness
It is to adjust the image overall brightness via linear adjustment mode. The larger the number is, the brighter the picture is, and on the contrary it is opposite. The picture get blurry easily when the value is set too big.
Contrast
It is to adjust the picture contrast. The bigger the value is, the bigger the bright contrast becomes, and on the contrary it is smaller. The dark area becomes darker and the bright area becomes overexposed easily when the value is set too big. The picture becomes blurry when the value is set too small.
Saturation
It is to adjust the color darkness and lightness. The color becomes darker when the value is bigger; on the contrary it becomes lighter. The value causes no influence to the overall brightness of the image.
Sharpness
It is to adjust the sharpness level of the picture edge. The bigger the sharpness value is, the more obvious the image edge becomes, the image is likely to generate noise more easily when the value is set too big.
Gamma
It is to change image brightness and improve the dynamic display range of the image via nonlinear adjustment mode. The bigger the value is, the brighter the picture becomes, and on the contrary it is opposite.
Mirror
After mirror is enabled, the monitoring image will be displayed invertedly.
Flip
It is to change the display direction of the monitoring image. It includes following options:
Normal: The monitoring picture is normally displayed. Flip mode 1: The monitoring picture is displayed with clockwise
rotation 90°
Flip mode 2: The monitoring picture is displayed with anticlockwise
rotation 90°
180°: The monitoring picture is displayed upside down.
Note:
Please set the video resolution as 1080P or lower when applying flip mode for some devices.
EIS
It can realize electronic anti-flicker function via comparison algorithm of image difference, which can effectively solve the problem of image jittering during application and it can make the image clearer.
Step 3 Click “Save” and complete the image parameter config of the camera.
Dahua Network Camera Web 3.0 Operation Manual
35
6.1.1.2 Exposure Step 1
Select “Setup > Camera > Conditions > Exposure”. The system will display the “Exposure” interface
which is shown in Figure 6-2.
Figure 6-2
Step 2 It is to set the exposure parameter, please refer to the following sheet for more details.
Parameter
Note
Anti-flicker
You can switch to exposure mode when it is in outdoor
mode, it can realize the result in the corresponding exposure mode.
50Hz: When the current is 50Hz, system can auto adjust the
exposure according to the environment brightness in case there is any stripe.
60Hz: When the current is 60Hz, system can auto adjust the
exposure according to the environment brightness in case there is any stripe.
Dahua Network Camera Web 3.0 Operation Manual
36
Parameter
Note
Mode
It is the camera exposure mode.
Note:
When “Anti-flicker” is “Outdor”, the “exposure mode” can be
set as “gain priority” or “shutter priority” mode.
Different devices have different exposure modes; please
refer to the actual interface. It includes the following options: Auto: It can auto adjust the image brightness according to
the environment. Gain priority: The device can auto adjust according to the
gain range which is set by priority during normal exposure
range according to the different scene brightness. The device
will auto adjust shutter value if the image brightness fails to
reach the effect and the gain value has reached to upper limit
or lower limit, which is to make the image reach the best
brightness. Shutter priority: The device can auto adjust according to the
shutter range which is set by priority during normal exposure
range according to the different scene brightness. The device
will auto adjust shutter value if the image brightness fails to
reach the effect and the shutter value has reached to upper
limit or lower limit, which is to make the image reach the best
brightness. Iris priority: Iris value is fixed, the device can auto adjust the
shutter value if the image brightness fails to reach effect and
the shutter value has reached the upper limit or lower limit,
the device can auto adjust the gain value to make the image
reach the best brightness. Manual: It is to manually set gain value and shutter value,
adjust the the displayed brightness of the image.
Auto Iris
It can set the parameter when the camera installs auto iris. The lens iris can auto adjust the size according to the
environment after auto iris is enabled, then the image
brightness will change accordingly. The iris value reaches the max when disabling auto iris, the
lens iris will not change according to the environment
brightness.
3D NR
It is to process the image with multiframe (at least two frames), it can realize noise reduction of the image by using the interframe information between the previous and latter frame.
Grade
It can set the parameter when “3D NR” is enabled. The bigger the grade is, the better NR effect it can realize.
Dahua Network Camera Web 3.0 Operation Manual
37
Step 3 Click “Save” to complete the parameter config of camera exposure.
6.1.1.3 Backlight Backlight mode can be divided into BLC, WDR and HLS. BLC: it can avoid cucoloris phenomenon of the darker area in the backlight environment. WDR: It can suppress the overbright area and compensate darker area by enabling WDR, which can make the overall image clear. HLC: It is to weaken the high light, which can be applied in the areas such as toll gate, entrance and exit of the parking lot and etc. As for extreme light, it can snapshot the human face in the dark environment and it can realize better effect for the details of the plate number.
Step 1
Select “Setup > Camera > Condition > Backlight”, the system will display the interface of “Backlight”
which is shown in Figure 6-3.
Figure 6-3
Step 2 Set the backlight parameter. When the “Mode” is set as “Scene Self-adaptation”, the system will auto adjust the image
brightness according to the environmental brightness, which is to make the object display clearly in the scene.
When the “Mode” is set as “BLC”, it can select default mode or customized mode.
When selecting “Default” mode, the system can realize auto exposure according to the
environment, which is to make the image in the darkest area clear to be seen.
Dahua Network Camera Web 3.0 Operation Manual
38
When selecting “Customized” mode, the system can realize exposure upon the selected area
after it set customized area, which is to make the image of the selected area reach appropriate brightness.
When the “Mode” is set as “WDR”, it will lower the brightness of the area with high brightness and
enhance the brightness of the area with low brightness, which is to make the objects in both high
brightness and low brightness area display clearly. Note: There may be video loss of a few seconds when the camera is switched from non WDR mode to WDR mode. When the “Mode” is set as “HLC”, the system will constrain the brightness of the area with high
brightness and decrease the size of the halo area, which is to lower the brightness of the whole
image. Step 3 Click “Save” to complete the config of the backlight mode.
6.1.1.4 WB WB is used to restore the white object in the scene by the camera, after WB mode is set, it can make the white object look white in different environments. Step 1
Select “Setup > Camera > Conditions > WB”, the system will display the interface of “WB”, which is
shown in Figure 6-4.
Figure 6-4
Step 2 Set WB mode.
Dahua Network Camera Web 3.0 Operation Manual
39
When the “Mode” is set as “Auto”, the system can auto compensate white balance upon different
color temperatures, which is to make the image color normal. When the “Mode” is set as “Natural”, the system can auto compensate white balance to the scene
without artificial light, which is to make the image color normal. When the “Mode” is set as “Street Lamp”, the system can auto compensate white balance to the
outdoor scene at night, which is to make the image color normal. When the “Mode” is set as “Outdoor”, the system can auto compensate white balance to the most
outdoor scenes with natural light and artificial light, which is to make the image color normal. When the “Mode” is set as “Manual”, it can manually set the value of red gain and blue gain; the
system can compensate the different color temperatures in the environment according to the
settings. When the “Mode” is set as “Regional Custom”, it is to set customized area, the system can
compensate white balance to different color temperature of the images in the area, which is to
make the image color normal.
Step 3 Click “Save” to complete the config of WB mode.
6.1.1.5 Day & Night It is to set the switch between color mode and black & white mode. Step 1
Select “Setup > Camera > Conditions > Day & Night” and the system will display the interface of “Day & Night”, which is shown in Figure 6-5.
Figure 6-5
Dahua Network Camera Web 3.0 Operation Manual
40
Step 2 Set day & night parameter; please refer to the following sheet for more details.
Parameter
Note
Mode
It is to set the camera image displayed as color or black & white mode.
Note:
The setting of “Day/Night Mode” is not affected by the setting of “Profile
Management”.
It includes the following options:
Color: The camera image is displayed as color image. Auto: The camera can auto select color image or black & white image
to be displayed according to the environmental brightness.
Black & white: The camera image is displayed as black & white image.
Sensitivity
The parameter can be set when the “Day/Night Mode” is “Auto”. It is to set the sensitivity of the switch between image color display and black & white display.
Delay
The parameter can be set when the “Day/Night Mode” is “Auto”. It is to set the switch delay between image color display and white & black display. The smaller the delay is, the faster of the switch becomes between color display and black & white display.
Step 3
Click “Save” to complete the config of day/night mode.
6.1.1.6 Defog The image quality will become weak when the device is in the environment with fog or haze, you can enable defog function to adjust the image definition. Step 1
Select “Setup > Camera > Conditions > Defog” and the system will display the interface of “Defog”
which is shown in Figure 6-6.
Dahua Network Camera Web 3.0 Operation Manual
41
Figure 6-6
Step 2 It is to set defog mode according to the actual scene. When the “Mode” is set as “Manual”, it is to manually set intensity and air light mode, the system
will adjust the image definition according to the intensity and air light mode which have been set
previously. As for air light mode, you can set manual or auto. When the “Mode” is set as “Auto”, the system will auto adjust the image definition according to the
actual scene. When the “Mode” is set as “Off”, then the defog function is disabled.
Step 3 Click “Save” to complete the config of defog mode.
6.1.1.7 IR Light You can directly set the mode of IR light if the device is equipped with IR light. Step 1
Select “Setup > Camera > Conditions > IR Light” and the system will display the interface of “IR Light”
which is shown in Figure 6-7.
Dahua Network Camera Web 3.0 Operation Manual
42
Figure 6-7
Step 2 It is to set IR light mode according to the actual scene. When the “Mode” is set as “Manual”, it can manually set the brightness of IR light; the system will
realize light compensation to the image according to the IR light intensity. When the “Mode” is set as “Smart IR”, the system can adjust the light brightness according to the
actual scene. When the “Mode” is set as “Zoomprio”, the system can auto adjust the IR light according to the
brightness change of the actual scene.
The system will enable near light by priority when the actual scene becomes dark, the system
will enable the far light when the near light fails to meet the requirement of scene brightness even if it is adjusted to the brightest.
The system will adjust far light brightness by priority to off and then adjust the brightness of
near light when the actual scene becomes bright. The system will always disable far light when the focal length of the lens is adjusted to a certain wide angle, which is to avoid near overexposure. Meanwhile, it can manually set light compensation to slightly adjust the brightness of IR light.
When the “mode” is set as “Off”, it will not enable the IR light.
Step 3 Click “Save” and complete the config of IR light.
Dahua Network Camera Web 3.0 Operation Manual
43
6.1.1.8 Profile Management Step 1
Select “Setup > Camera > Conditions > Profile Management” and the system will display the interface of
“Profile Management”.
Step 2 Set profile management. When the “Profile Management” is set as “Normal”, the system will monitor according to the normal
config.
Figure 6-8
When the “Profile Management” is set as “Full Time”, you can select “Always Enable” in “Day” or
“Night’, the system will monitor according to the config of “always enable”.
Figure 6-9
When the “Profile Management” is set as “Schedule”, you can set some period as day and another
period as night, for example, if it sets 0:00~12:00 as day, 12:00~24:00 as night, then the system will
monitor by adopting corresponding config in different periods.
Dahua Network Camera Web 3.0 Operation Manual
44
Figure 6-10
Step 3 Click “Save” to complete the settings of profile management.
Note:
Click “Default” to restore the device to default config; click “Refresh” to check the latest config file of the
device.
6.1.1.9 Zoom and Focus
Note:
Only motorized vari-focal devices support focus and zoom function. Step 1
Select “Setup > Camera > Conditions > Zoom and Focus” and the system will display the interface of “Zoom and Focus” which is shown in Figure 6-11.
Figure 6-11
Dahua Network Camera Web 3.0 Operation Manual
45
Step 2 Adjust the focal length of the lens. After it is zoomed, set “Speed” and press “+”, “-“or drag the sliding block directly to adjust. Step 3 Adjust the lens definition. After it is focused, set “Speed” and press “+”, “-“or drag the sliding block directly to adjust.
Note:
 Speed is used to set the length by pressing “+” and “-“. After adjusting the focal length of the lens or click “Auto Focus”, the device will auto adjust the
image definition, it is not allowed to implement other lens operation during auto focus. After several times of zoom and focus, the image fails to be adjusted clear, click “Restore All’ to
reset the lens to zero and remove the accumulative error of the lens. Click “Refresh” and the device will automatically synchronize the hardware to the location of sliding
block of lens zoom and focus.
6.1.2 Video
6.1.2.1 Video Step 1
Select “Setup > Camera > Video > Video” and the system will display the interface of “Video” which is
shown in Figure 6-12 (Non fisheye) or Figure 6-13 (Fisheye).
Figure 6-12 (Non fisheye)
Dahua Network Camera Web 3.0 Operation Manual
46
Figure 6-13 (Fisheye)
Step 2 Set video bit stream, please refer to the following sheet for more details about the parameters.
Parameter
Function
Installation Mode
It will display the parameter when the device is fisheye. There are three installation modes for fisheye which are ceiling, wall mount and ground installation, please select installation mode according to the actual installation scene of the fisheye. The system will begin to switch after switching installation mode, it will prompt successfully saved after it is switched successfully.
Note:
The device end will output the dewarped video stream after configuring installation and record mode, when the device is accessed to third-party platform, it will directly display the dewarped image on the third-party platform.
Dahua Network Camera Web 3.0 Operation Manual
47
Parameter
Function
Record Mode
It will display the parameter when the device is fisheye. The system will begin to switch after record mode is switched, it will prompt saved successfully after it is switched successfully. The record mode will change according to the different installation modes.
1O: the original picture which is not dewarped. 1P: 360°rectangular panorama. 2P: The mode can be set when the “Installation
Mode” is set as “Ceiling” or “Ground”. It is the 2 related 180°rectangular image, the two sub windows can both form 360°panorama anytime.
1O+3R: original image + 3 independent sub
images, both the sub image and sub boxes in the original image can support zoom and movement.
1R: Original image + independent sub image, the
sub boxes of the original image support zoom and movement.
4R: original image + 4 independent sub images,
both the sub image and sub boxes in the original image support zoom and movement.
2R: Original image + 2 independent sub images,
the sub boxes of the original image can support zoom and movement, the sub image supports up and down movement, which can change the vertical angle of view.
Note:
The device end will output dewarped video stream after configuring installation and record mode, when the device is accessed to the third-party platform, it will directly display the dewarped image on the third-party platform.
Sub Stream Enable
Select “Enable” to enable sub stream. The device supports enabling sub stream 1 and sub stream 2 at the same time.
Smart Codec
It can enhance image compression performance and reduce storage space by enabling intelligent encoding.
Note:
After intelligent encoding is enabled, the device will not support third stream, ROI or intelligent event detection, please refer to the actual interface for more details.
Dahua Network Camera Web 3.0 Operation Manual
48
Parameter
Function
Encode mode
There are five options: H.264 (main profile standard, H.264H (high profile standard), H.264B (Baseline Profile), H.265 (main profile standard) and MJPEG encode. The H.264, H.264H both are H264 bit stream.
H.264 is the Main Profile encode and you need to enable the sub stream function in your camera and set the resolution as CIF. Then you can monitor via the Blackberry cell phone.
The H.265 is the main profile encode mode. MJPEG: In this encode mode, the video needs to
large bit stream to guarantee the video definition. You can use the max bit stream value in the recommend bit to get the better video output effect.
Resolution
There are multiple resolutions. You can select from the dropdown list.
For each resolution, the recommended bit stream value is different.
Note: When video is under rotating status, you cannot set resolution higher than 1080P (excluding 1080P).
Video Clip
The function is only supported by sub stream 2, please refer to “Video Clip” for more details below the sheet.
Frame Rate (FPS)
PAL: 125f/s1-50f/s NTSC: 130f/s or 1~60f/s. The frame rate may vary due to different resolutions.
Bit Rate Type
There are two options: VBR and CBR. Please note, you can set video quality in VBR mode. Under MJPEG mode, only CBR is available.
Recommended Bit
Recommended bit rate value according to the resolution and frame rate you have set.
Bit Rate
In CBR, the bit rate here is the max value. In
dynamic video, system needs to low frame rate or video quality to guarantee the value.
The value is null in VBR mode.
Please refer to recommend bit rate for the detailed
information.
SVC
Frame rate can be encoded by layer. It is a flexible encoding method. By default, it is 1 as 1 layer. You also can set 2/3/4 layers.
I Frame
Here you can set the P frame amount between two I frames. The value ranges from 1 to 150. Default value is 50.
Recommended value is frame rate *2.
Dahua Network Camera Web 3.0 Operation Manual
49
Parameter
Function
Watermark Settings
Select “Watermark Setting” and enable watermark
function. After the watermark function is enabled, you can check if the video is tampered via verifying watermark character.
Watermark Character
It is the character of watermark verification; it is Digital CCTV by default.
Video Clip
1. Select “Sub Stream 2” in the drop-down box, click “Enable”.
2. Enable “Video Clip”, click .
The system will display the interface of “Area”, which is shown in Figure 6-14.
Figure 6-14
Dahua Network Camera Web 3.0 Operation Manual
50
3. Select the needed resolution and clip the needed image on the interface, which is shown in Figure
5-15.
4. Click “Save”. You can check the clipped video in the preview interface (the sub stream 2 preview
interface only displays the clipped area), which is shown in Figure 6-15.
Figure 6-15
Step 3 Click “Save” to complete video stream setup.
6.1.2.2 Snapshot The snapshot interface is shown as in Figure 6-16.
Dahua Network Camera Web 3.0 Operation Manual
51
Figure 6-16
Please refer to the following sheet for detailed information.
Parameter
Function
Snapshot type
There are two modes: general (schedule) and Event (activation).
Image size
It is the same as the resolution of main stream. Quality
It is to set the image quality. There are six levels.
Interval
It is to set snapshot frequency. Optional1~7s/picture, customized.
6.1.2.3 Video Overlay The video overlay interface is shown as in Figure 6-17.
Figure 6-17
Dahua Network Camera Web 3.0 Operation Manual
52
Figure 6-18
Figure 6-19
Dahua Network Camera Web 3.0 Operation Manual
53
Figure 6-20
Figure 6-21
Dahua Network Camera Web 3.0 Operation Manual
54
Figure 6-22
Please refer to the following sheet for detailed information.
Parameter
Function
Privacy Masking
Here you can privacy mask the specified video in the
monitor video.
System max supports 4 privacy mask zones.
Time Title
You can enable this function so that system overlays time
information in video window.
You can use the mouse to drag the time tile position.
Channel Title
You can enable this function so that system overlays
channel information in video window.
You can use the mouse to drag the channel tile position.
Text Overlay
You can enable this function to overlay text in video
window.
Private protocol is connected to mobile NVR, support GPS
information overlay.
You can use the mouse to drag location box to adjust its
position. Alignment include align left and align right.
Picture Overlay
You can enable this function to display overlay picture.
Click on disable to turn it off.
Click on Upload Picture to overlay local picture into
monitoring window. You can drag the yellow box to move it.
Note:
You cannot enable text and picture overlay at the same time.
Dahua Network Camera Web 3.0 Operation Manual
55
Counting
Check “Enable” to display the counting statistics data in
the video monitoring window; check “Disable” not to
display.
There are enter number and leave number for statistics
type and left align and right align for OSD info.
Refresh
Set privacy mask, channel title, time title, location, overlay
and save the change. You can click on Refresh to see effect.
Default
Click it to restore default config.
Save
Click it to complete video settings.
6.1.2.4 ROI Note: Some series don’t support ROI setup function.
Figure 6-23
Dahua Network Camera Web 3.0 Operation Manual
56
Figure 6-24
Parameters
Note
Enable
Check “Enable”, then it will display the ROI in the video monitoring window; Check “Disable”, then it won’t display.
Image Quality
Set the image quality of ROI, ranging from 16, default is 6.
Note: For fisheye device, it ranges from 1~6 (best), default is 6 (best)
Able to set area block, max 4 areas.
6.1.2.5 Path The storage path interface is shown as in Figure 6-25. Here you can set snap image saved path and the record storage path.
The default monitor image path is C:\Users\admin\WebDownload\LiveSnapshot. The default monitor record path is C:\Users\admin\WebDownload\LiveRecord. The default playback snapshot path is C:\Users\admin\WebDownload\PlaybackSnapshot.
The default playback download path is C:\Users\admin\WebDownload\PlaybackRecord. The default playback cut path is: C:\Users\admin\WebDownload\VideoClips. Note: Admin is locally logged in PC account. Please click the Save button to save current setup.
Dahua Network Camera Web 3.0 Operation Manual
57
Figure 6-25
6.1.3 Audio
Please note some series devices do not support audio function.
6.1.3.1 Audio The audio interface is shown as below. See Figure 6-26.
Figure 6-26
Please refer to the following sheet for detailed information.
Dahua Network Camera Web 3.0 Operation Manual
58
Parameter
Function
Enable
You can enable audio only when video is enabled. After selecting the “Enable” of main stream or sub stream, the
network transmission stream is the audio/video composite stream, otherwise it only includes video image.
Encode mode
The encode mode of the main stream and extra stream include G.711A, G.711Mu, G.726 and ACC. The default mode is G.711A.
The setup here is for audio encode mode and the bidirectional talk encode both.
Sampling Frequency
The sampling frequency of audio. It includes the following options:
8K 16K 32K 48K 64K
AudioIn Type
Two modes to select: LineIn, Mic. Device needs to connect external audio input source under
LineIn mode, and it doesn’t need to connect external audio
input source under Mic mode.
Noise Filter
Enable the function and it can filter relevant noise.
Microphone Volume
Adjust microphone volume from 0100. Note: Supported by some devices.
Speaker Volume
Adjust speaker volume from 0100. Note: Supported by some devices.
6.1.3.2 Alarm audio
Dahua Network Camera Web 3.0 Operation Manual
59
Figure 6-27
Figure 6-28
Audio management currently supports PCM format to record and PCM, wav two forms to uploadand can select an audio file for the audio alarm linkage. The way to download the web alarm playback audio file into local is as follows:
Step 1 Use the left mouse button to click the hollow circle in the “choice” column on the left, and shows which means effective choice of alarm audio.
Step 2 Use the right mouse button to click select “save target as” to download.
6.2 Network
6.2.1 TCP/IP
The TCP/IP interface is shown as in Figure 6-29. It supports IPv4 and IPv6. IPv4 supports static IP and DHCP. IPv6 supports static IP only. When users manually modify IP address, WEB will automatically jump to the new IP address.
Dahua Network Camera Web 3.0 Operation Manual
60
Figure 6-29
Please refer to the following sheet for detailed information.
Parameter
Function
Host Name
It is to set current host device name. It max supports 15 characters.
Ethernet Card
Please select the Ethernet port. Default is wired. Please note you can modify the default Ethernet card if there is
more than one card.
Mode
There are two modes: static mode and the DHCP mode. Select DHCP mode, it auto searches IP, and you cannot set IP/subnet mask/gateway. Select static mode, you must manually set IP/subnet mask/gateway.
Mac Address
It is to display hose Mac address.
IP Version
It is to select IP version. IPV4 or IPV6. You can access the IP address of these two versions.
IP Address
Please use the keyboard to input the corresponding number to modify the IP address and then set the corresponding subnet mask and the default gateway.
Preferred DNS
DNS IP address.
Alternate DNS
Alternate DNS IP address.
Dahua Network Camera Web 3.0 Operation Manual
61
Enable ARP/Ping set device IP address service.
You can use ARP/Ping command to modify or set the device IP address if you know the device MAC address.
Before the operation, please make sure the network camera and the PC in the same LAN. This function is on by default.
You can refer to the steps listed below. Step 1: Get an IP address. Set the network camera and the PC
in the same LAN. Step 2: Get the physical address from the label of the network
camera. Step 3: Go to the Run interface and then input the following
commands.
arp –s <IP Address> <MAC>
ping –l 480 –t <IP Address>
Such asarp -s 192.168.0.125 11-40-8c-18-10-11
ping -l 480 -t 192.168.0.125
Step 4: Reboot the device. Step 5: You can see the setup is OK if you can see there are
output information such as “Reply from 192.168.0.125 …” from
the command output lines. Now you can close the command line.
Step 6: Open the browse and then input http://<IP address>. Click the Enter button, you can access now.
6.2.1.1 Easy4ip
Click “Enable” to connect the device to network, and then you can connect to the device via mobile
client of Easy4ip after “Online” is displayed on the interface (connection mode: add device serial number
or scan QR code). See Figure 6-30.
Figure 6-30
Dahua Network Camera Web 3.0 Operation Manual
62
6.2.2 Connection
6.2.2.1 Connection The connection interface is shown as in Figure 6-31.
Figure 6-31
Please refer to the following sheet for detailed information.
Parameter
Function
Max connection
It is the max Web connection for the same device. The value ranges from 1 to 20. Default connection amount is 10.
TCP port
Port range is 1025~65534. The default value is 37777. You can input the actual port number if necessary.
UDP port
Port range is 1025~65534. The default value is 37778. You can input the actual port number if necessary.
HTTP port
Port range is 1025~65524. The default value is 80. You can input the actual port number if necessary.
Dahua Network Camera Web 3.0 Operation Manual
63
RTSP port
The default value is 554. Please leave blank if use default. User uses
QuickTime or VLC can play the following formats. BlackBerry can play too.
Real-time monitoring URL format, please require real-time RTSP
media server, require channel no., bit stream type in URL. You may need username and password.
User uses BlackBerry need to set encode mode to H.264B, resolution
to CIF and turn off audio. URL format is: rtsp://username:password@ip:port/cam/realmonitor?channel=1&subtype=0 Username/password/IP and port. The IP is device IP and the port default value is 554. You can leave it in
blank if it is the default value. Follow standard RTP protocol and when encode mode is MJPEG, the max
resolution only supports 2040*2040.
HTTPs Port
HTTPs communication port, range is 1025~65534, default is 443.
Note: 01024, 3778037880, 1900, 3800, 5000, 5050, 9999, 37776, 39999, 42323 are all special ports.
User cannot modify them.
Avoid using default port value of other ports.
6.2.2.2 ONVIF ONVIFOpen Network Video Interface Forum),this standard describes network video mode,
interface, data type and data interaction mode. ONVIF Standard’s aim is to achieve a network video frame agreement and makes the network video products (including video front-end, video equipment, etc.) from different manufacturers completely compatible.
ONVIF function is on by default.
Dahua Network Camera Web 3.0 Operation Manual
64
Figure 6-32
6.2.3 PPPoE
The PPPoE interface is shown as in Figure 6-33. Enter the PPPoE username and password which are provided by ISP (Internet Service Provider), and click “Enable”. The network camera will automatically establish network connection in the mode of PPPoE after it is enabled; after it is successful, the IP of the “IP Address” will be automatically modified into the dynamic IP address of the acquired WAN.
Note:
After PPPoE dial-up is successful, it needs to log in the device via the IP which is set before dial-up; in the PPPoE setup interface, it will display the registered IP address, and then it can visit the IP address via client.
Please disable UPnP when clicking PPPoE enable, which is to avoid causing influence to PPPoE dial­up.
Dahua Network Camera Web 3.0 Operation Manual
65
Figure 6-33
6.2.4 DDNS
The DDNS interface is shown as in Figure 6-34. The DDNS is to set to connect the various servers so that you can access the system via the server. Please go to the corresponding service website to apply a domain name and then access the system via the domain. It works even your IP address has changed. When the device connects to WLAN, you should disable UPnP.
Figure 6-34
Please refer to the following sheet for detailed information.
Dahua Network Camera Web 3.0 Operation Manual
66
Parameter
Function
Server Type
You can select DDNS protocol from the dropdown list: CN99 DDNS, NO-IP DDNS, Dyndns DDNS, and Dahua DDNS. The default is Dahua DDNS.
Server Address
DDNS server IP address CN99 DDNS Server address: www.3322.org NO-IP DDNS Server address: dynupdate.no-ip.com Dyndns DDNS Server address: members.dyndns.org Dahua DDNS
Server addresswww.dahuaddns.com
Mode
Default is auto, able to choose manual
Domain Name
Both auto and manual are “MAC addresss.dahuaddns.com”by default, able to set prefix manually.
Username
The user name you input to log in the server, optional.
The CN99 DDNS interface is shown as in Figure 6-35.
Figure 6-35
Dahua Network Camera Web 3.0 Operation Manual
67
Parameter
Function
Server Type
You can select CN99 DDNS protocol
Server Address
Under CN99 DDNS the default server address is www.3322.org
Domain Name
Self-defined domain name
Username
The user name you input to log in the server.
Password
The password you input to log in the server
Refresh Period
The refresh period of the connection between the device IP and the server, default is 10 minutes.
6.2.5 IP filter
The IP filter interface is shown as in Figure 6-36. You can enable IP filter function so that some specified IP/MAC user can access the network camera. You can add IP address or IP segment. If you do not check the box here, it means there is on access limit. Here you can add IP address and MAC address. You must add these addresses before enabling the trusted sites. Please note: You must set MAC address in the same network segment.
Figure 6-36
6.2.6 SMTP e-mail)
The SMTP interface is shown as in Figure 6-37.
Dahua Network Camera Web 3.0 Operation Manual
68
Figure 6-37
Please refer to the following sheet for detailed information.
Parameter
Function
SMTP Server
Input server address and then enable this function.
Port
Default value is 25. You can modify it if necessary.
Anonymity
For the server which supports the anonymity email function, it won’t display the information of the sender.
User Name
The user name of the sender email account.
Password
The password of sender email account.
Sender
Sender email address.
Authentication (Encryption mode)
You can select SSL, TLS or none. Title (Subject)
Input email subject here.
Attachment
System can send out the email of the snapshot picture once you check the box here.
Mail receiver
Input receiver email address here. Max three addresses.
Dahua Network Camera Web 3.0 Operation Manual
69
Parameter
Function
Interval
The send interval ranges from 0 to 3600 seconds. 0 means there is no interval. Please note system will not send out the email immediately when the alarm occurs. When the alarm, motion detection or the abnormity event activates the email, system sends out the email according to the interval you specified here. This function is very useful when there are too many emails activated by the abnormity events, which may result in heavy load for the email server.
Health mail enable
Please check the box here to enable this function.
Email test
The system will automatically sent out a email once to test the connection is OK or not .Before the email test, please save the email setup information.
6.2.7 UPnP
It allows you to establish the mapping relationship between the LAN and the public network. Here you can also add, modify or remove UPnP item. For UPnP on different routers, you must disable UPnP function. See Figure 6-38. In the Windows OS, From Start->Control Panel->Add or remove programs. Click the “Add/Remove Windows Components” and then select the “Network Services” from the Windows Components Wizard.
Click the Details button and then check the “Internet Gateway Device Discovery and Control client” and “UPnP User Interface”. Please click OK to begin installation.
Enable UPnP from the Web. If your UPnP is enabled in the Windows OS, the network camera can auto detect it via the “My Network Places”. Under manual mode, you can modify external port. Under auto mode, select idle port for auto port mapping without user modification.
Dahua Network Camera Web 3.0 Operation Manual
70
Figure 6-38
6.2.8 SNMP
The SNMP interface is shown as in Figure 6-39 and Figure 6-40. The SNMP allows the communication between the network management work station software and the proxy of the managed device. Please install the software such as MG MibBrowser 8.0c software or establish the SNMP service before you use this function. You need to reboot the device to activate the new setup.
Figure 6-39
Please refer to the following sheet for detailed information.
Dahua Network Camera Web 3.0 Operation Manual
71
Parameter
Function
SNMP Version
Check SNMP v1, device only process v1 info. Check SNMP v2, device only process v2 info. Check SNMP v3, can set username, password and
encryption method. Server calibrate corresponding
username, password and encryption method too access
device and v1/v2 are unavailable.
SNMP port
The listening port of the proxy program of the device. It is a UDP port not a TCP port. The value ranges from 1 to 65535. The default value is 161
Community
It is a string, as command between management and proxy, , defining a proxy, and a manager’s authentication.
Read community
Read-only access to all SNMP targets, default is public. Note: Only number, letter, _, and – supported.
Write community
Read/write access to all SNMP targets, default is private. Note: Only number, letter, _, and – supported.
Trap address
The destination address of the Trap information from the proxy program of the device.
Trap Address
Address where to send Trap message.
Trap Port
Port which send Trap message, default is 162, range 1~65535.
Figure 6-40
Dahua Network Camera Web 3.0 Operation Manual
72
Check SNMP v3 version and SNMP port, read community, write community, Trap address, Trap port are same with SNMP v1 and SNMP v2 versions. Only when SNMP version is SNMP v3, users need to configure parameter in chart.
Parameter
Function
SNMP Version
SNMP v3
Read-only Username
Default is public. Note: Name only can be number, letter and underline.
Read/Write Username
Default is private. Note: Name only can be number, letter and underline.
Authentication
You may select MD5 or SHA, default is MD5.
Authentication Password
Password not less than 8 characters. Encryption
Default is CBC-DES.
Encryption Password
Password not less than 8 characters.
6.2.9 Bonjour
The Bonjour interface is shown as below. See Figure 6-41. Bonjour is based on the multicast DNS service from the Apple. The Bonjour device can automatically broadcast its service information and listen to the service information from other device. You can use the browse of the Bonjour service in the same LAN to search the network camera device and then access if you do not know the network camera information such as IP address. You can view the server name when the network camera is detected by the Bonjour. Please note the safari browse support this function. Click the Display All Bookmarks: and open the Bonjour, system can auto detect the network camera of the Bonjour function in the LAN.
Dahua Network Camera Web 3.0 Operation Manual
73
Figure 6-41
6.2.10 Multicast
The multicast interface is shown as in Figure 6-42. Multicast is a transmission mode of data packet. When there is multiple-host to receive the same data packet, multiple-cast is the best option to reduce the broad width and the CPU load. The source host can just send out one data to transit. This function also depends on the relationship of the group member and group of the outer.
Note
Open preview, streaming media protocol, select multicast, and monitor via multicast format. Here you can set multicast address and port. You also need to go to Live interface to set the
protocol as Multicast.
Figure 6-42
Please refer to the following sheet for detailed information.
6.2.11 4G
Parameter
Function
Enable
Select to enable multicast function. Main stream and sub stream cannot be used at the same time.
Multicast address
Main/sub stream multicast default address is 224.1.2.4 and its range is
224.0.0.0239.255.255.255.
Port
Multicast port. Main stream is 40000, sub stream1 is 40016,sub stream2 is 40032 and the range is 102565534.
Dahua Network Camera Web 3.0 Operation Manual
74
Note: This function is only for series with 4G module. 4G is a mobile communication system which makes wireless communication integrates with Internet and multimedia communication.
6.2.11.1 Dialing Setting
Figure 6-43
Parameter
Function
Wireless Net Type
Auto, WCDMA, FDD-LTE optional, you can select according
to the operator.
Enable
Check to enable 4G module.
APN
It shall be acquired from the operator according to the setup of operator.
Authentication Mode
Auto, PAP and CHAP, the authentication algorithm is different according to different operators.
Dial-up Number
The number is different according to different operator, it can be acquired from operator.
User name
It shall be acquired from the operator.
Password
It shall be acquired from the operator.
Update Period
It is the period beyond the dial-up period which has been set, it is 30s by default, which means the device can auto acquire 4G dial-up status, cut off dial-up to save flow.
Dahua Network Camera Web 3.0 Operation Manual
75
Time Range
It is the time period to set dial-up. It can activate the function
via message to enable/disable dial-up function if it is beyond the time period.
IP Address
It will display the acquired IP after the dial-up is successful via 4G.
6.2.11.2 Mobile Setting
Figure 6-44
Please refer to the following sheet for detailed information.
Parameter
Function
Message Send
In the event, after the corresponding message activation is enabled, it will send message to the phone of receiver when event happens. It needs to enable the function of message activation function in the event interface when using the function.
Message Activation
It can send message ON/OFF to the SIM card inside the device by the mobile phone in the list, which is to enable /disable the dial-up function and send REBOOT to restart the device.
Phone Activation
You can use the mobile phone in the calling list to call the SIM card inside the device to enable dial-up function.
6.2.12 WIFI
Dahua Network Camera Web 3.0 Operation Manual
76
Note:
Some series devices don’t support WIFI and WPS function. WPS function is supported by the devices with WPS button.
6.2.12.1 WIFI WIFI info can show the name, status, IP information of the Current Hot Spot. Usually please “Refresh” WIFI work information after reconnection to ensure the real-time display of the work status, because it often takes some time to connect WIFI Hot Spot, which depends on the network signal strength.
Figure 6-45
WIFI setting method is as follows:
Step 1 Click show as means enabling WIFI function. Step 2 Click “ Search SSID, and shows the wireless network hot spot of the current network camera
environment in the list.
Dahua Network Camera Web 3.0 Operation Manual
77
Figure 6-46
Step 3 Click “Add SSID” when need to add a wireless network manually pop out an interface in
the figure below, and enter network ID in the dialog box.
Figure 6-47
Step 4 Double click on one can pop out the signal intensity and authentication of the hot spot.
· Please enter the password if necessary. Please keep the choice of password index number same as the router when entering password.
· Please click “connect” if it is unnecessary to enter the password.
6.2.12.2 WPS
Dahua Network Camera Web 3.0 Operation Manual
78
Figure 6-48
PIN Number and SSID are both acquired from the router, please “refresh” the work information of WIFI to ensure the real-time display of work state after filling in correctly.
6.2.13 802.1x
802.1x (port based network access control protocol) supports manual selection of authentication method to control if device connected to LAN can join the LAN. It well supports authentication, charging, safety and management requirement of network.
Figure 6-49
Please refer to the following sheet for detailed information.
Dahua Network Camera Web 3.0 Operation Manual
79
Parameter
Function
Authentication
PEAP (protected EAP protocol).
Username
It needs the username to login, which is authenticated by the server.
Password
Please input password here.
6.2.14 QoS
The QoS interface is shown as below. See Figure 6-50. Qos (Quality of Service) is network security mechanism. It is a technology to fix the network delay and jam problem and etc. For the network service, the quality of service includes the transmission bandwidth, delay, the packet loss and etc. We can guarantee the transmission bandwidth, lower the delay, and reduce the loss of the data packet and anti-dither to enhance the quality. We can set the DSCP (Differentiated Services Code Point) of the IP to distinguish the data packet so that the router or the hub can provide different services for various data packets. It can select the different queues according to the priority (64 different priority levels) of the packets and select the bandwidth of the each queue. Level 0 is the lowest, and level 63 is the highest. It can also discard at the different ratio when the broad bandwidth is jam.
Figure 6-50
Please refer to the following sheet for detailed information.
Parameter
Function
Real-time monitor
The value ranges from 0 to 63. The router or the switcher can provide different service for various data packets.
Dahua Network Camera Web 3.0 Operation Manual
80
Parameter
Function
Command
The value ranges from 0 to 63. The router or the switcher can provide different service for various data packets.
Enable Wireless QoS
Check it to enable QoS.
6.2.15 HTTPs
In the HTTPs setting interface, users can make PC log in normally via HTTPs by creating certificate or uploading signed certificate, which is to guarantee the security of communication data and provide safeguard for user information and device security with reliable and stable technical means. Step 1 Create certificate or upload the signed certificate. Please refer to the following steps if you select “Create Certificate”.
1. Select “Setup > Network > HTTPs”, and the system will display the interface of HTTPs, which is
shown in Figure 6-51.
Figure 6-51
2. Click “Create” and it will pop out the dialog box of “HTTPs”, which is shown in Figure 6-52.
Dahua Network Camera Web 3.0 Operation Manual
81
Figure 6-52
3. Fill in corresponding “Country”, “Province” and some other information; click “Create” after filling in. It will show the prompt of “Create Successfully”, which means the server certificate has been successfully created.
Note:
Make sure the “IP or domain name” is the same as that of the device.
4. Click “Install” and it will install the certificate on the device end, which is shown in Figure 6-53.
Dahua Network Camera Web 3.0 Operation Manual
82
Figure 6-53
5. Click “Download”. It will pop out the dialog box of “Save as”, save the file into the computer.
Dahua Network Camera Web 3.0 Operation Manual
83
Figure 6-54
6. Double click the downloaded icon of “RootCert.cer”. The system will display the information interface of “Certificate”, which is shown in Figure 5-55.
Figure 6-55
7. Click “Install Certificate” and it will pop out the interface of “Certificate Import Wizard”, which is shown in Figure 6-56.
Dahua Network Camera Web 3.0 Operation Manual
84
Figure 6-56
8. Click “Next”. Select “Trusted Root Certification Authorities”, which is shown in Figure 6-57.
Dahua Network Camera Web 3.0 Operation Manual
85
Figure 6-57
9. Click “Next”. The system will display the interface of “Completing the Certificate Import Wizard”, which is shown in Figure 6-58.
Dahua Network Camera Web 3.0 Operation Manual
86
Figure 6-58
10. Click “Finish”, and it will pop out the dialog box of “Security Warning”, which is shown in Figure
6-59.
Dahua Network Camera Web 3.0 Operation Manual
87
Figure 6-59
11. Click “Yes”. It will pop out the dialog box of “Import Successful”, click “Ok” to complete downloading certificate, which is shown in Figure 6-60.
Figure 6-60
Please refer to the following steps if you select “Install Signed Certificate”.
1. Select “Setup > Network > HTTPs”. The system will display the interface of HTTPs, which is shown in Figure 6-61.
Dahua Network Camera Web 3.0 Operation Manual
88
Figure 6-61
2. Select signed certificate and certificate key path respectively via “Browse”, click “Upload”.
3. Install root certificate, please refer to step 6~11 for more details.
4. Check “Enable HTTPs”, click “Save”. The system will display the dialog box of “Need to reboot the device”, and then the config is valid.
Figure 6-62
5. Use HTTPs
Use HTTPs to log in. Enter https://xx.xx.xx.xx in the browser, and it will pop out normal login interface; the browser will prompt certificate error if the certificate is not installed, which is shown in Figure 6-63.
Dahua Network Camera Web 3.0 Operation Manual
89
Figure 6-63
Note:
“xx.xx.xx.xx” is corresponding to your IP or domain name.
6.3 Event
6.3.1 Video detection
6.3.1.1 Motion Detection
Step 1
Select “Setup > Event > Video Detection > Motion Detection’ and the system will display the interface of “Motion Detection” which is shown in Figure 6-64.
Dahua Network Camera Web 3.0 Operation Manual
90
Figure 6-64
Step 2 Select “Enable” to enable motion detection function. Step 3 Set motion detection area.
Dahua Network Camera Web 3.0 Operation Manual
91
1. Click “Setup” and the system will pop out the interface of “Setting Area”, which is shown in Figure 6-65
Figure 6-65
2. Set area name, it is to set valid area of motion detection according to the actual situation, and it can set the value of sensitivity and threshold respectively. The bigger the sensitivity is, the easier it is to generate motion detection, the smaller the threshold is, the easier it is to generate motion detection; the entire video image is the valid area of motion detection by default.
Note:
Different colors represent different areas; each area can set different detection area. The red line in the Oscillogram means triggering motion detection; green line means not triggering
motion detection.
3. Click “Save” to complete area setting.
Step 4 It is to set other parameters of motion detection, please refer to the following sheet for more details.
Dahua Network Camera Web 3.0 Operation Manual
92
Parameter
Function
Working Period
Note:
It is to set the alarm period, it can enable alarm event only during the period range which has been set.
1. Click “Setup” and the system will pop out the interface of “Working Period”.
2. It is to set working period according to the following methods:
Press the left mouse button and drag it on the setup interface to set. Click " There are six periods to be set every day, select the check box in front
of the period, and then the period is valid.
Select week number (it selects Sunday by default, if it selects the
whole week, then it means the setup can be applied to the whole week, you can also select the check box in front of the week number to implement independent setting for some days).
3. Click “Save” to complete the setup of working period.
Anti-dither
System only memorizes one event during the anti-dither period. The value ranges from 0s to 100s.
Area
1. Click “Setup” and the system will pop out the interface of “Set Area”.
2. Set the area name, it is to set the valid area of motion detection according to the actual situation, and it can set its sensitivity and threshold respectively. The higher the sensitivity is, the easier it is to trigger motion detect, the smaller the area threshold is, the easier it is to generate motion detect, the whole video image is the valid area of the motion detect by default.
Note:
Different colors represent different areas; each area can set different detection areas. The red line in the Oscillogram means triggering motion detect, the green line means not triggering motion detect.
3. Click “Save” to complete area setup.
Record
Check it and so when alarm occurs, system will auto record. You shall set record period in Storage>Schedule and select auto record in record control interface.
Record Delay
System can delay the record for specified time after alarm ended. The value ranges from 10s to 300s.
Relay out
Enable alarm activation function. You need to select alarm output port so that system can activate corresponding alarm device when alarm occurs.
Alarm Delay
System can delay the alarm output for specified time after alarm ended. The value ranges from 10s to 300s.
Send Email
If you enabled this function, System can send out email to alert you when alarm occurs and ends. User can set email address in Network>SMTP.
Audio linkage
Check it and the system will play alarm audio file when alarm occurs. Users can set the recorded or uploaded audio file in “camera setting audio alarm audio.
Flash linkage
Check it and the flash will be on when alarm occurs, and the flash will be off until the end of alarm after corresponding delay.