
Important Safety Instructions
RISK OF FIRE AND/OR ELECTRIC SHOCK
This product should be installed and maintained by a
qualified Electrician ONLY, in accordance with all
applicable electrical codes.
Make sure the power is OFF before installing or
servicing. Never attempt to install or remove a fixture
from an energized circuit. Disconnect power at fuse or
circuit breaker before installing or servicing.
Proper grounding is required to ensure personal safety.
Inspect all units for damage prior to installation.
Do not alter, relocate or remove wiring, lamp holders,
ballast, drivers or any other electrical component.
Do not allow flammable or combustible materials to
accumulate on fixture.
Always wear appropriate personal protective equipment
(PPE) during installation, maintenance or handling.
Important Safety Instructions
HAZARDOUS LOCATIONS
Remove fixture from hazardous locations before
attempting any maintenance.
Do not return fixture to service in hazardous locations if
seals have been broken or product is damaged.
This fixture is made of aluminum and is not suitable for
use in underground mines where explosive atmospheres
may exist.
To maintain explosion proof integrity, make sure all
threads are fully engaged.
Thank you for purchasing a DAGR Industrial Lighting fixture – one of the most
durable LED fixtures on the market. Our lights have been engineered, tested and
certified to ensure optimum performance in the industry’s toughest environments.
When installed, operated and maintained in accordance with product specifications
and instructions, your new LED fixture can be expected to provide many years of
reliable lighting performance and energy savings.
If you have any questions about the use and maintenance of your DAGR LED fixture,
please contact us toll-free at 1.866.203.0040 or email info@DAGRlighting.com.
Product Unpacking
This fixture has been packed to avoid damage during transit. Inspect the fixture to confirm there is no damage prior
to installation. Do not install a damaged fixture or change fixture components.
DAGRlighting.com Page 1 FL570.1406.IM
1.866.203.0040 May 2014

European Union (EU) (IEC 60446)
Operating Environments
LED technology differs from previous forms of lighting. The driver is capable of accepting a range of input voltages, but
requires a consistent supply of power. Drivers are able to withstand minor voltage drops and surges, but should not be
subject to frequent power fluctuations. The fixture should not be operated at voltage and current inputs below or
exceeding those listed under the unit’s operating parameters. Lighting circuits should be designed to ensure sufficient
and stable voltage and current are delivered to the unit.
Temperature limits for hazardous locations are listed on the certificate of conformance as well on the product label
attached to the fixture and presented later in this document. For optimal performance and longevity, the standard
operational environment of the fixture should not routinely exceed 35°C. Continuous operation at high ambient
temperatures will decrease the longevity of the driver. Under abnormally high ambient temperatures, the driver will
decrease power output as ambient temperatures approach and exceed 50oC and may go into protection mode.
Wiring
Wiring of this product must be performed by a qualified electrician and all electrical connections made in accordance
with the National Electrical Code, any applicable local code requirements and hazardous location requirements.
Typical Current Draw: 70W Fixture — 1.4A / 115VAC
140W Fixture — 2.8A / 115VAC
Mounting
Fixture may become damaged and/or unstable if not installed properly. This fixture should be mounted using the
mounting bracket provided. Do not mount in a fashion that putts strain on the electrical cord or cord connector. Note:
Fixture may become damaged and/or unstable if not installed properly.
Ensure that all mounting hardware is fully tightened and will not loosen. If mounted in areas subject to vibration,
ensure mounting methodology will not allow wear or shear on mounting hardware. A secondary method of securing
the fixture to the support can be employed as an additional safety measure.
Maintenance
Perform visual, electrical, and mechanical inspections on a regular basis. The environmental and operating conditions,
in conjunction with a preventive maintenance program, should be used to determine inspection frequency. We
recommend an Electrical Preventive Maintenance Program as described in the National Fire Protection Association
Bulletin NFPA No. 70B: Recommended Practice For Electrical Equipment Maintenance (www.nfpa.org).
To prevent heat build-up, remove dust from the LED housing. The lens should be cleaned periodically to ensure
continued lighting performance. Do not use an abrasive, strong alkaline or acid cleaner as damage may result.
DAGRlighting.com Page 2 FL570.1406.IM
1.866.203.0040 May 2014

This product consists of:
Mounting bracket
Housing
Power supply
LED arrays
Internal reflector
Glass lens
Electrical cord and cord connector
(not shown)
Warranty
Fixtures come with a 5-year warranty when installed in a fixed location, such as in a building. The product has a limited
1-year warranty when installed and used in any mobile application. Visit DAGRlighting.ca for full warranty details.
Product Dimensions (mm) – FL570-140W
Unit Weight – FL570-140W
12.6 kg
Units per Box – FL570-140W
2
DAGRlighting.com Page 3 FL570.1406.IM
1.866.203.0040 May 2014

This product consists of:
Mounting bracket
Housing
Power supply
LED arrays
Internal reflector
Glass lens
Electrical cord and cord connector
(not shown)
Product Dimensions (mm) – FL570-70W
Unit Weight – FL570-70W
8.25 kg
Units per Box – FL570-70W
2
DAGRlighting.com Page 4 FL570.1406.IM
1.866.203.0040 May 2014

Certification and Conformance
This product conforms to UL and CSA standards for LED luminaires. It is approved for use in Class II, Division 1, Groups E, F, G; and
Class III hazardous locations.
Conformance certifications can be found at http://www.labtestcert.com/labtest/
Limitation of Liability
All statements, technical information and recommendations contained in this document are based on information and
test results we believe to be reliable. The accuracy or completeness thereof is not guaranteed. As conditions of use are
outside our control, the purchaser should determine the suitability of the product for his/her intended use and assumes
all risk and liability whatsoever in connection therewith.
NOTE: Product specifications and dimensions are subject to change without notice.
DAGRlighting.com Page 5 FL570.1406.IM
1.866.203.0040 May 2014