SPECIFICATIONS
POWER SUPPLY 230V AC, 50Hz SINGLE PHASE WITH GROUNDING
INPUT POWER 1000 W
MICROWAVE ENERGY OUTPUT 700 W
FREQUENCY 2,450MHz
OUTSIDE DIMENSIONS (W H D) 446 x 270 x 319 mm
CAVITY DIMENSIONS (W H D) 295 x 219 x 303 mm
CAVITY VOLUME 20 L
NET WEIGHT APPROX. 10.6 Kg
TIMER 35min. DUAL SPEED
POWER SELECTIONS 5 Levels
* Specifications are subject to change without notice.
17
(TROUBLE 1) Oven does not operate at all ; any inputs can not be accepted.
TROUBLESHOO TING GUIDE
Following the procedure below to chec k if the o ven is defective or not.
1. Check grounding before trouble checking.
2. Be careful of the high voltage circuit.
3. Discharge the high voltage capacitor.
4. When checking the continuity of the switches, fuse or high voltage transformer, disconnect one lead wire from these parts
and check continuity with the AC plug removed. To do otherwise may result in a false reading or damage to your meter.
Does the
fuse blow?
NO
NONO
Does the fan motor work when you
shut the door and turn the timer?
YES
If outlet has proper voltage, check
continuity of power supply cord.
Replace power supply cord.
NO Continuity
Check continuity of interlock
monitor switch with door shut.
Replace primary, secondary interlock
switch and interlock monitor switch.
Continuity
Both continuity
Replace fuse and check
continuity of both interlock
switch's contact and monitor
switch's contact with door
partially open until monitor
switch contact.
Replace primary, secondary interlock
switch and interlock monitor switch.
NO
Fuse again
Disconnect one side of the
lead wire connected from
transformer to the high
voltage capacitor, and operate
oven.
Replace high voltage capacitor.
Replace high voltage transformer
Normal
(NOTE1)
(NOTE1)
NOTE1 : All these switches must be replaced at the same time, please refer to “Interlock Mechanism And
Adjustment”