: In this Manual, some parts can be changed for improving, their
performance without notice in the parts list. So, if you need the
latest parts information,please refer to PPL(Parts Price List) in
Service Information Center (http://svc.dwe.co.kr).
7.Machine room view and part list--------------------------------------------------------------------7
8. Main components----------------------------------------------------------------------------------------- 8
9. Door color specification-------------------------------------------------------------------------------- 11
10. Exploded view and parts list ------------------------------------------------------------------------ 14
11. Electronic function -------------------------------------------------------------------------------------- 20
Page 3
1. SPECIFICATION
MODEL NAMEFR-440MFR-440P
Refirgerant
Cooling System
Refrigeration System
Defrost System
Defrost Operation
Cold Control
Capacity
External
Dimension
Net Weight 72Kg 72Kg
R12 160g 160g
R134a 130g 130g
Fan Cooling Convection
Air Forced Convection
Fin Evaporator Forced
Automatic Start & Stop
Adjustable Dial Adjustable Button
Freezer
Refrigerator
Total
Height 1762mm 1762mm
Width 650mm 650mm
Depth 650mm 650mm
95
95
271
366
271
366
1
Page 4
2. EXTERNAL VIEW
1624473.51048.5140
60
650
1256.5
580
1161097.5
1762
532.5610
1. FR-440M
6407.5
580
650
1256.5
640
16
24
473.5
60
1048.5140
2459224
1762
6
532.5
10
1161097.5
650
2. FR-440P
640
7.5
640
24592 24
650
2
Page 5
3. WIRE DIAGRAM
1. FR-440M
RD: RED
GN: GREEN
BR: BROWN
WH: WHITE
PK: PINK
BK: BLACK
YW: YELLOW
BL: BULE
GY: GRAY
WH/BL : WHITE WITH
: BLUE STRIPE
TEMP
FUSE
WH/BL
THERMOSTAT
YW
GY
WH/BL
WH
HEATER
DEFROST
1
M
3
DEFROST
TIMER
BI-METAL
BRWH
2
4
YW
RD
YW
L/BLBKBK
GN/YW
1
DOOR
3
S/W
2
BL
PK
LAMP
COMPRESSOR
A
M
OL
PTC
P-RELAY
PLUG
FAN
MOTOR
YW
RD
BR
2. FR-440P
F-PCB
PATTERN
FUSE
VAR
F/M RY
HTR RY
COMP RY
BLUE X 2
D-SENSORF-SENSOR
M-PCB
TRANS
SNUBBER
COMP
ORANGE X 2
COM
FAN
HTR
S/N
220V
BLUE
GRAY
VIOLET
GREEM
WHITE
PINK
GREEN
DOWN
TRANS
VIOLET
FM
PINK
BLACK
GRAY
BLACK
DEFROST
TEMP
FUSE
HEATER
WHITE
COMPRESSOR
OL
PTC
P-RELAY
BLACK
GREEN
BLACK
GN/YW
2
PINK
1
BLACK
DOOR
3
SWITCH
BLUE
R-LAMP
YELLOW
YELLOW BROWN
L/BLUE
PLUG
3
Page 6
4. NAME OF PARTS
1. FR-440M
18
2
1
3
4
5
6
7
8
10
9
11
12
13
14
17
15
16
1 Freezer Shelf
2 Case Icing
3 Case Ice
4 Case Child
5
Refrigerator
Temperature Controller
6 Shelf Refrigerator
7 Crisper Cover
8 Crisper
9 Adjustable Foot
10 Front Grille
11 Freezer Door Pocket
12 Egg Pocket
13 Case Egg
14 Refrigerator Pocket(SM)
15 Refrigerator
Pocket(Medium)
16 Refrigerator Pocket(BG)
17 Deodorant(Option)
18 Freezer Temperature
Controller
2. FR-440P
2
1
3
4
5
6
7
8
10
9
11
12
13
14
17
15
16
1 Freezer Shelf
2 Case Icing
3 Case Ice
4 Case Child
5
Refrigerator Temperature
Controller
6 Shelf
Refrigerator
7 Crisper Cover
8 Crisper
9 Adjustable Foot
10 Front Grille
11 Freezer Door Pocket
12 Egg Pocket
13 Case Egg
14
Refrigerator
15
Refrigerator
Pocket(SM)
Pocket(Medium)
16
Refrigerator
Pocket(BG)
17 Deodorant(Option)
4
Page 7
5. AIR FLOW DIAGRAM
Freezer door pocket
Do not put ice cream or frozen
food in freezer door pocket to
store for a long term. Opening
and shutting the door can rise up
the temperature.
-16~-18
-16~-18
Freezer room
Do not put any bottle such as
beer or beverage because it can
be frozen and broken.
Cold air absorbing duct
Do not place food in front
of the duct because it is the
entrance of the cold air.
Refrigerator door pocket
Temperature is high even if the
pocket is in the middle.
When storing margarine or cheese
for one or two weeks, make use
of the refrigerator shelf.
Crisper
Suitable in storing fruits or
vegetable.
Wrapping can prevent from
dryness.
2~4
3~5
3~5
2~4
-17~-19
5~7
A
1~32~4
B
1~32~4
C
2~3
Refrigerating room
This model is multi-flow type
which flows out cold air from
each shelf space. The hot air
after making the refrigerator
cold, flows into cooling system
through the front upper part.
Do not put food having much
moisture at the middle part of
each shelf space ("A", "B" and
"C" part). It can be frozen owing
to the low temperature.
5
Page 8
6. REFRIGERANT CYCLE DIAGRAM
HOT PIPE
AUX-HOT PIPE
BACK PLATE PIPE
AUX-HOT PIPE
ACCUM
FIN CROSS
EVA
DRYER
MAIN CAPI TUB.
COMP
SUC-PIPE
M
C
O
P
R
E
S
S
O
R
A
U
X
I
C
O
N
P
I
P
E
H
O
T
P
I
P
E
A
U
X
I
H
O
T
P
I
P
E
B
A
C
K
P
L
A
T
E
P
I
P
D
R
Y
E
R
C
A
P
I
T
U
B
E
E
V
A
P
O
R
A
T
O
R
A
C
C
U
M
U
A
O
S
U
C
P
I
L
P
E
T
R
E
COOLING PIPE
6
Page 9
7. MACHINE ROOM VIEW AND PART LIST
16
15
14
13
12
11
20
11
10
8
9
5
23224 3 2 1 2112 7 6
19
NOPART NAMENOPART NAMENOPART NAME
1 COMPRESSOR 9 PIPE CON (SUC)17CABLE CLAMP
2 ABSORBER10PIPE COOLING CON (AUX)18STARTING CAPACITOR
3 BOLT COMP. FIXTURE11PIPE COOLING (A)19POWER CORD
4 FIXTURE COMP. WASHER12PIPE CON (P.A)20ABSORBER PIPE
5 PLATE AUX-CON AS13SCREW MACHINE21VIBRATIONPROOF MASS(B)
6 CASTER PIN14DRAIN HOSE(B) AS22SWITCH P-RELAY AS
7 CASTER15TAPE OPP23RELAY BAND
8DRYER16CEC COVER
7
Page 10
8. MAIN COMPONENTS
1. COMPRESSOR
Refrigerant R12
Voltage 100V/50,60Hz 110V/60Hz
Comp. model X CL23YE-3-C CL23Y-1-C CL23Y-2-C SL27YE-5-C PL25YE-4 X SL27YE-5-C
Part code X 3957123C30 3951123C10 3957123C20 3954127C80 3956125442 X 3954127C80
Strating type X CSIR CSIR CSIR RSIR RSCR x RSIR
Refrigerant R134a
Voltage 100V/50,60Hz 110V/60Hz
Comp. model X HBL23YE-3- C HBL23YE-1-C X HSL27YE-5-C X HSL27YE-5- C HSL27YE-5-C
Part code X 3952123L20 3952123L10 X 3954127L50 X 3954127L50 3954127L50
Strating type X CSR CSR X RSIR X RSIR RSIR
2. RELAY ASSEMBLY
Refrigerant R12
Voltage 100V/50,60Hz 110V/60Hz
Relay model X 427THBYY-52 414THBYY-5 2 232THBYY-5 2197SHBYY-52 X 232THBYY-52
Part code X 3018108120 3018109740 3018103090 3018103010 X 3018103090
115, 120V/60Hz
115, 120V/60Hz
115, 120V/60Hz
127V/60Hz 220V/50Hz 220V/60Hz 230V/50Hz
127V/60Hz 220V/50Hz 220V/60Hz 230V/50Hz
127V/60Hz 220V/50Hz 220V/60Hz 230V/50Hz
240V/50Hz
240V/50Hz
240V/50Hz
Refrigerant R134a
Voltage 100V/50,60Hz 110V/60Hz
Relay model X 427THBYY-52 X 276THBYY-52 X 276THBYY-5 2276THBYY-52
Part code X 3018108120 X 3018105031 X 3018109510 3018105031
3. RUNNING CAPACITOR
Refrigerant R12
Voltage 100V/50,60Hz 110V/60Hz
Spec.
Part code
Refrigerant R134a
Voltage 100V/50,60Hz 110V/60Hz
Spec.
Part code
4. STARTING CAPACITOR
Refrigerant R12
Voltage 100V/50,60Hz 110V/60Hz
Spec.
Part code
X X X X X 350V/5 µF X X
X X X X X 400EL15110X X
X 300V/7 µF X X X X X
X 386100400X X X X X
X 140V/100µF
X
115, 120V/60Hz
115, 120V/60Hz
115, 120V/60Hz
115, 120V/60Hz
127V/60Hz 220V/50Hz 220V/60Hz 230V/50Hz
127V/60Hz 220V/50Hz 220V/60Hz 230V/50Hz
127V/60Hz 220V/50Hz 220V/60Hz 230V/50Hz
127V/60Hz 220V/50Hz 220V/60Hz 230V/50Hz
X X X X
X X X X
240V/50Hz
240V/50Hz
240V/50Hz
240V/50Hz
Refrigerant R134a
Voltage 100V/50,60Hz 110V/60Hz
Spec.
Part code
X 200V/100µF
X 3016400100
115, 120V/60Hz
127V/60Hz 220V/50Hz 220V/60Hz 230V/50Hz
X X X 290V/50 µF X
X X X 4124G62020X
8
240V/50Hz
Page 11
5. F-FAN MOTOR
Refrigerant R12, R134a
Voltage 100V/50,60Hz 110V/60Hz
Spec.
Part code
6. DEFROST HEATER
Refrigerant R12, R134a
Voltage 100V/50,60Hz 110V/60Hz
Spec.
Part code
7. LAMP ASSEMBLY
Refrigerant R12, R134a
Voltage 100V/50,60Hz 110V/60Hz
Spec.
Part code
8. DEFROST TIMER (FR-440M)
Refrigerant R12, R134a
Voltage 100V/50,60Hz 110V/60Hz
Spec. X TMDEX09UA1 TMDEX09UC1
Part code X 3018101200 3018100300
X 3210DWNFH-2
X 401VB42021
X 148W
X 400EL22311
X 10W
X 4019S15200
115, 120V/60Hz
115, 120V/60Hz
115, 120V/60Hz
115, 120V/60Hz
127V/60Hz 220V/50Hz 220V/60Hz 230V/50Hz
127V/60Hz 220V/50Hz 220V/60Hz 230V/50Hz
127V/60Hz 220V/50Hz 220V/60Hz 230V/50Hz
127V/60Hz 220V/50Hz 220V/60Hz 230V/50Hz
3210DWNFF-23210DWNFD-13210DWNFI-1
401VA42021 4017G24502 401UB42021
148W
400EL22211
13W
400EL20111
240V/50Hz
240V/50Hz
240V/50Hz
240V/50Hz
9. PCB TRANSFORMER (FR-440P)
Refrigerant R12
Voltage 100V/50,60Hz 110V/60Hz
Part code
Refrigerant R134a
Voltage 100V/50,60Hz 110V/60Hz
Part code
10. MAIN PCB ASSEMBLY (FR-440P)
Refrigerant R12
Voltage 100V/50,60Hz 110V/60Hz
Spec.
Part code
Refrigerant R134a
Voltage 100V/50,60Hz 110V/60Hz
Spec.
Part code
11. DRYER
X 5EPK041506
X 5EPK041506
X P717
X 3014300940
X P717
X 3014300920
115, 120V/60Hz
115, 120V/60Hz
115, 120V/60Hz
115, 120V/60Hz
127V/60Hz 220V/50Hz 220V/60Hz 230V/50Hz
5EPK041504 5EPK041507
127V/60Hz 220V/50Hz 220V/60Hz 230V/50Hz
5EPK041504 5EPK041507 X 5EPK041030 5EPK041504
127V/60Hz 220V/50Hz 220V/60Hz 230V/50Hz
127V/60Hz 220V/50Hz 220V/60Hz 230V/50Hz
3014300910
3014300930
240V/50Hz
5EPK041508
240V/50Hz
240V/50Hz
240V/50Hz
Refrigerant R12 R134a
Spec.
Part code 3016800103 3016801100
10 g 15 g
9
Page 12
POWER CORD SPECIFICATION
NO SHAPE OF POWER CODE PART CODE DESCRIPTION REMARK
1 3011315000 CP-2PIN FOR EUROPEAN COUNTRY
2 401RA17200 CP-2PIN FOR OTHER COUNTRY
3 4006D17101 KP-30 FOR AMERICA
4 401PD17101 KP-211 FOR JAPAN & TAIWAN
5 3011300801 BP-3PIN
6 3011303010 #267 FOR CHILE
7 3011315310 FOR ISRAEL
8 3011303050 BS-1363A
9 3011301200 KP-551/550 FOR CHINA & AUSTRALIA
FOR U.K, MIDDLE ASIA
SINGAPORE & MALAYSIA
* Upper power cord’s part code is only for lead wire, without any kinds of terminal or housing.
NO PART CODE PART NAME DESCRIPTION QUANTITY REMARK
1 ASSY URT CAB 1
2 4018G54120 PIPE DRN AL T1.0 1
3 4018G45110 GUIDE DRN AL 1
4 HTR GLASS TUBE AS 1 REFER TO # 9
5 4017Z73570 COVER DEFR HTR *T AL 1
6 4017Z73580 COVER DEFR HTR *U AL 1
7 3017044800 EVA FIN SAS 1
8 3018111100 SWITCH BIMTL AS 1
9 400EL21213 FUSE TEMP AS 1
10 4017Z90590 FIXTURE FUSE TEMP PP 1
11 4017Z40622 FOOT *F ASS 2
12 4017Z40192 ADJ FOOT AS PP 2
13 3010302800 BASE COMP 1
14 3010100201 ABSORBER COMP NR H=40 4
15 3014504001 PLATE AXCON AS SGCC 1
16 COMPRESSOR 1 REFER TO # 8
17 SWITCH P RELAY AS 1 REFER TO # 8
18 4019H09030 SPECIAL WASHER SWRH 4
19 3012900640 HINGE *M AS ZN DC-2 1
20 3016000220 SPECIAL SCREW M6X16 SWCH22A 2
21 3010023400 SWITCH DR AS 1
22 MOTOR FAN AS 1 REFER TO # 9
23 4017Z42312 FAN ABS 1
24 4017Z28490 COVER M/PCB PP 1
25 3010501600 BOX CONTL AS 1
26 3010500403 BOX CONTL HIPS 1
27 3018300401 THERMOSTAT 1
28 4017G31041 KNOB C/S ABS 1
29 401QA26000 ASSY R/DAMPER 1
30 4010Y26030 INSULATOR DAMP B F-PS 1
31 4010Y21300 DAMPER R AS D-704 1
32 4010C31261 INSULATOR DAMP A F-PS 1
33 4017Z18180 KNOB ABS 1
34 4010Y22130 COVER DAMP HIS 1
35 3017901410 SOCKET LAMP AS 1
36 4010Y75203 MULTI DUCT AS 1
37 4010Y75213 DUCT MULTI HIPS 1
38 4010Y75221 INSULATOR M/F DUCT F-PS 0.033 1
39 LAMP AS 1 REFER TO # 9
15
Page 18
NO PART CODE PART NAME DESCRIPTION QUANTITY REMARK
40 4017Z87570 SHADE R HC-2 1
41 4010C75252 LABEL DUCT PC T0.17 1
42 DRYER AS 1 REFER TO # 9
43 ASSY URT *T DOOR 1 REFER TO # 11
44 4018G35011 POCKET F *T HC-2 2
45 4018Z46017 LINER F DR ABS 1. 4 X 682 X 1116 1
46 4010Y47100 GASKET F DR AS PVC-S+NR+MAGNET 37 1
47 4010G51402 HINGE *T AS SPHC 1
48 3016000301 SPECIAL SCREW M5X14 S1018C ZN5 MICRO 3
49 4010G51455 COVER *T HI PP 42 1
50 ASSY URT *U DOOR 1 REFER TO # 11
51 4010Y47200 GASKET R DR AS PVC-S+NR+MAGNET 37 1
52 4018Z37018 DR INL R ABS 1.4X682X1138 1
53 3012900401 HINGE *U AS MF-ZN5-C 1
54 3016000600 SPECIAL SCREW M6X20 4
55 4017Z91110 CASE VAPORI PP 1
56 3011413001 COVER V/CASE AS 1
57 4017Z97171 CASE EGG 2
58 4018G35113 POCKET EGG HIPS 2
59 4017Z68414 POCKET BOTL HIPS 2
60 4010E30312 CASE CHILD 1
61 3011703201 DOOR CHILD AS 1
62 4017Z99112 CASE ICE HC-2 1
63 4018G30011 CRISPER HC-2 1
64 4010E55211 SHELF R GPS 2
65 4010Y44515 COVER PLT *F PP 1
66 4010G56011 CASE ICING PE-HD 1
67 4018Z75502 INSULATOR F LUVR AS 1
68 4018Z75115 LOUVER F PP 1
69 4017Z1068A COVER MECH ROOM PP (JI-36) 1
70 4010E55112 SHELF F 1
16
Page 19
2. FR-440P
1.Explode view
17
Page 20
2. Parts list
✔ Caution :
NO PART CODE PART NAME DESCRIPTION QUANTITY REMARK
1 ASSY URT CAB 1 REFER TO # 75
2 4018G54120 PIPE DRN AL T1.0 1
3 4018G54110 GUIDE DRN AL 1
4 HTR GLASS TUBE AS 1 REFER TO # 62
5 4017Z73570 COVER DEFR HTR *T AL 1
6 4017Z73580 COVER DEFR HTR *U AL 1
7 3017044800 EVA FIN SAS 1
8 400EL30141 SENSOR TEMP AS FD10 1
9 3012001102 FIXTURE TEMP SENS PP 1
10 400EL21213 FUSE TEMP AS 1
11 4017Z90590 FIXTURE FUSE TEMP PP 1
12 4017Z40622 FOOT *F ASS 2
13 4017Z40192 ADJ FOOT AS PP 2
14 3010302800 BASE COMP 1
15 3010100201 ABSORBER COMP NR H=40 4
16 3014504001 PLATE AXCON AS SGCC 1
17 COMPRESSOR 1 REFER TO # 61
18 SWITCH P RELAY AS 1 REFER TO # 61
19 4019H09030 SPECIAL WASHER SWRH 4
20 TRANSFORMER PCB 1 REFER TO # 62
21 3012900640 HINGE *M AS ZN DC-2 1
22 3016000220 SPECIAL SCREW M6¡¿16 SWCH22A 2
23 3010023400 SWITCH DR AS 1
24 MOTOR FAN AS 1 REFER TO # 62
25 4017Z42312 FAN ABS 1
26 PCB MAIN AS 1 REFER TO # 62
27 4017Z80430 FIXTURE M/PCB PP 1
28 4017Z28490 COVER M/PCB PP 1
29 401QA26000 ASSY R/DAMPER 1
30 4010Y26030 INSULATOR DAMP B F-PS 1
31 4010Y21300 DAMPR R AS D-704 1
32 4010C31261 INSULATOR DAMP A F-PS 1
33 4017Z18180 KNOB ABS 1
34 4010Y22130 COVER DAMP HIS 1
35 3017901410 SOCKET LAMP AS 1
36 4010Y75203 MULTI DUCT AS 1
37 4010Y75213 DUCT MULTI HIPS 1
38 4010Y75221 INSULATOR M/F DUCT F-PS 0.033 1
39 LAMP AS 1 REFER TO # 62
In this Service Manual, some parts can be changed for improving, their performance without notice in the parts list.
So, if you need the latest parts information, please refer to PPL (Parts Price List) in Service Information Center
(http://svc.dwe.co.kr)
18
Page 21
NO PART CODE PART NAME DESCRIPTION QUANTITY REMARK
40 4017Z87570 SHADE R HC-2 1
41 4010C75252 LABEL DUCT PC T0.17 1
42 DRYER AS 1 REFER TO # 62
43 ASSY URT *T DOOR 1 REFER TO # 76
44 4018G35011 POCKET F *T HC-2 2
45 4018Z46017 LINER F DR ABS 1.4¡¿682¡¿1116 1
46 4010Y47100 GASKET F DR AS PVC-S+NR+MAGNET 37 1
47 401QA45300 PANL *F.C AS 1
48 4010Y45010 PANL *F.C ABS 1
49 3014300900 PCB *F AS 1
50 401QA45350 LABEL C/B 1
51 4010Y45022 COVER F CP 1
52 4017Z18160 F CP CNTR KNOB 1
53 4010G51402 HINGE *T AS SPHC 1
54 3016000301 SPECIAL SCREW M5¡¿14 S1018C ZN5MICRO 3
55 4010G51455 COVER *T HI PP 42 1
56 ASSY URT *U DOOR 1 REFER TO # 76
57 4010Y47200 GASKET R DR AS PVC-S+NR+MAGNET 37 1
58 4018Z37018 DR INL R ABS 1.4¡¿682¡¿1138 1
59 3012900401 HINGE *U AS MF-ZN5-C 1
60 3016000600 SPECIAL SCREW M6¡¿20 4
61 4017Z91110 CASE VAPORI PP 1
62 3011413001 COVER V/CASE AS 1
63 4017Z97171 CASE EGG 2
64 4018G35113 POCKET EGG HIPS 2
65 4017Z68414 POCKET BOTL HIPS 2
66 4010E30312 CASE CHILD 1
67 3011703201 DOOR CHILD AS 1
68 4017Z99112 CASE ICE HC-2 1
69 4018G30011 CRISPER HC-2 1
70 4010E55211 SHELF R GPS 2
71 4010Y44515 COVER PLT *F PP 1
72 4010G56011 CASE ICING PE-HD 1
73 4018Z75502 INSULATOR F LUVR AS 1
74 4017Z29010 BRACKET F SENS SPCC 1
75 4018Z75115 LOUVER F PP 1
76 4010E55112 SHELF F 1
77 4017Z1068A COVER MECH ROOM PP(JI-36) 1
19
Page 22
11. ELECTRONIC FUNCTION
1. FR-440P
1) How to use the panel
Freezer Section Temp. Indicator LED
It checks the temp. In freezer section. If the Temp. Is
more than -5ûC, the warm temperature LED is
turned on, and if it is less than -5ûC, the normal
temperature LED is turned on.
Normal Temp. LED
Warm Temp. LED
Quick freezing SW
Quick Freezing
Pressing the quick freezing switch turns on LED and
performs quick freezing (COMP is operating for 90
min continuously.)
Pressing the switch again turns off LED and stops
Quick freezing.
Quick feezing LED
Temperature Control dial
It is used for changing the temperature in freezer
compartment.
Temperature control range:
ONOFF
Low-11ûC-17ûC
High-21ûC-27ûC
20
Page 23
2) Function table
NO.
1Quick COMP.
ControlControl
FunctionObjects
FreezingFan
LED
ContentsRemark
1. If press the quick freezing switch, then illuminates quick
freezing LED and starts quick freezing. (If press again, then
stops quick freezing)
2. COMP. and Fan operate for 90 min continuously.
3. After 90 min. F-sensor checks the temperature. If it is COMP.
on temperature, it continues quick freezing until it reaches
COMP off temperature.
4. If it becomes auto defrosting time during quick freezing,
defrosting starts from Pre-cool after finishing quick freezing.
5. If quick freezing switch is turn on during defrosting Pre-cool,
defrosting starts from Pre-cool after finishing quick freezing.
But if COMP. has been operating for more than 40 min., the
Pre-cool will be omitted.
2Freezer tem-COMP.
perature controlFan
3Prevent COMP.COMP.
restartingFan
4Warm & LED
normal
TEMP.
LED
5DefrostCOMP.
Fan
Heater
6. If quick freezing switch is turned on during Defrosting Heater
on or Fan delay, it performs quick freezing just after finishing
defrosting. But the quick freezing LED comes on immediately.
1. COMP. on/off temperature is controlled by F-sensor.
2. Usually COMP. and the fan operates simultaneously.
1. Restarting in 6 min. after COMP. off.
1. If F-sensor detects temperature over -5ûC, warm temperature
LED is on.
2. During defrosting, the normal temperature LED is always on
and F-sensor detects the temperature after finishing defrosting.
3. In quick freezing, warm temperature LED and normal
temperature LED are off.
PRE-COOLDefrosting
COMP.
Fan
D-heater
Prior rangequick freezingdefrosting
Fan & COMP.
delay
21
Page 24
NO.
Control Control
Function Objects
Contents Remark
1.After accumulated 13 hours of COMP. operation, it enters to
defrosting mode.
2.When power is loaded for the first time or when instant power
failure occurs, D-sensor detects temperature below 3.5˚C. It
immediately enters into defrosting mode.
3.During Pre-cool period, it operates COMP. and fan for 40 min.
regardless of F-sensor.
4.After finishing Pre-cool, the D-heater is immediately turned on.
5.At D-sensor temperature 13˚C, the D-heater stops.
6.If the D-heater does not stop within 1.5 hours, it enforcedly
turns off D-heater.
7.Fan, COMP. operates in 5 min. unconditionally after finishing
defrosting.
8.The defrosting LED is always on from Pre-cool to fan & COMP.
delay.
6. Forced defrost Heater
7. Term COMP.
Fan
Heater
1.It is set by forced defrosting switch.
2.It can not be set when D-sensor temperature is above 3.5˚C.
3.Manual reset is not possible.
4.If the D-sensor detect 13˚C the D-heater stops.
Mode Usually Usual short
Prevent COMP. restart 6 min. 0 sec.
Delay after switch on 2 sec. 0 sec.
Accumulated COMP
operation time
Quick freezing 90 min. 10 sec.
Defrosting Pre-cool 40 min. 2 sec.
Maximum D-heater on 90 min. 10 sec.
COMP & fan delay 5 min. 2 sec.
13 hours 40 sec.
22
Page 25
3) Circuit and wiring diagram
+
–
+
F-PCB
SVR
B10K
SW01
KPT-1103
LD02
KLG114E
LD03
KLY114E
LD01
KLR114E
ResistanceCODE Resistance
YR01
R06
10K
GREEN
ORANGE
R01
33ohm
R02
33ohm
BLACK
R04
33ohm
320 440
133R17 84.5
21.5R19 22.1
21.5R35 22.1
64.9R36 61.9
20.5R41 21.0
21.5R42 22.1
WHITE
VIOLET
RED
CN01
BLUE
YAW025-02
OUT B
OUT A
– IN A
+ IN A
– IN B
+ IN B
YCC
P4
1
2
3
4
5
6
7
Temyw025-07
Freezing Room
Temp
Control
GND
SW
Quick Freezing
LED
Normal
LED
High
LED
Quick Freezing
1N4148
DBL 3339
(TOP VIEW)
–
+
–
R36
61.9K F
R33 C24
D10
C22
10µF
–
+
+–+
YW025-02
P6
Short Mode
SHORT : Short
OPEN : Normal
+
C29
10µF
10K
0.01µF
R32
10K
C18
0.01µF
C18
0.01µF
C15
0.01µF
C21
330pF
330pF
R30
C20
10K
+
14
OUT C
13
OUT D
12
GND
11
+ IN D
10
– IN D
9
+ IN C
8
– IN C
R9
10K
R28
R27
R25
C30
240ohm
240ohm
360ohm
CSB400P
RE
0.01µF
R17
R31
10K
1
TEST SW
2
3
mode
4
13
14
GND
22
24
O-SW
23
S-SW
9
LO-LED
10
HI-LED
11
S-LED
12
Q-LED
5
EXTAL
R29
1M
6
XTAL
8
IC1
RESET
R11
10K
F-TEMP
26
C11
1µF
27
S-TEMP
R10
10K
28
HI/LO LED
C15
1µF
R13
LM6416F-2246
25
D-TEMP
C13
+
DS-CHIO
19
R5
10K
DF-SW
21
COMP
18
20
YCC
C9
10µF
R7
15
D-LED
390ohm
17
D-HTR
100ohm
R14
510ohm
10K
R12
R15
510ohm
10K
R20
510ohm
R24 510ohm C28
P7
R5
10K
+
84.5K
2.2M
C15
0.01µF
84.5K F
11
YW025-02
C31
0.1µF
LED
R3
1K
C5
0.1µF
21K F
R41
7
6
R42
22.1K F
IC4
R15
12
R23
R5
10K
4.7µF
5V
R18
10.2K F
3
7
+
–
2
6
+
R19
C14
10µF
R18
10.2K F
9
8
R39
21.5K F
Forced Defrosting Mode
SHORT : Forced Defrosting
OPEN : Normal Mode
COMP RELAY
RY2
HR-CR3130012
Q2
D9
1N4148
D7
R2
R1
1.5K
100K
C31
0.1µF
C3 C2
78057812
++++
0.33µF
KTA562Y
KLR114E
C8
D8
8
22.1K F
+
–
+
++
1N4148
1N4148
C26
+
10µF
F-SENSOR Temp/Resistance
Temp Resistance
ON
Warm
OFF
ON
Normal
OFF
ON
Cold
OFF
ON
High/
Normal
OFF
D13
1N4148
D11
1N4148
D14
1N4148
C15
D12
10µF
1N4148
RY1
HR-703VH
D8
1N4148
Q1
KTC1959Y
12V
D5
1N4002
1000µF
C6
0.1µF
IC2IC1
-11˚C
-17˚C
-15˚C
-22˚C
-21˚C
-27˚C
-5˚C
-5˚C
R35
22.1K F
R34
21.5K F
SX1
D15
YAR2
VAR
1N4002X4
576
D2
0.1µF
C4
C1
470µF
D304
13.746K
18.937K
17.937K
24.947K
23.612K
33.244K
10.098K
10.098K
TRANS
D1
FUSE1
250V 0.8A
220V
COMP
FN-SN
HTR
FRB-27
HTRP3
FAN
COM
P5 ORANGE
P2
P1
PCB
ORANGE
BLUE
BLUE
GREEN
PINK
WHITE
1S-3210
DWNFD
GREEN
BLACK
VIOLET
3
4
MAX) 150mA
MIN) 30mA
TRANS
F-SENSOR
D-SENSOR
F/M
VIOLET
BLACK
250V 7A
BLACK
BLACK
P-RELAY
YELLOWYELLOW
GREEN
GREEN
Defrost Heater GREY GREYTEMP FUSE
327ohm
PINK
BLACK
1
2
2
1
3
BLUE
240V 13W
P20H-220
COMP
PL21N1-4
BLACK
70+/-5˚C
Door Switch
LAMP
POWER CORD
23