DAEWOO DTQ-21U6SSV, DTQ-21U6SSFV, DTQ-20S1SSFV Service Manual

Caution
: In this Manual, some parts can be changed for improving. their performance without notice in the parts list. So, if you need the latest parts information, please refer to PPL(Parts Price List)in Service Information Center.
Service Manual
Color Television
MAR. 2006
CHSSIS MODEL
CN-402FN DTQ-20S1SSFV
DTQ-2130SSFV DTQ-21D7SSPV DTQ-21U6SSFV DTQ-21U6SSV
-1-
SAFETY PRECAUTIONS 2 SPECIFICATIONS 5 CIRCUIT BLOCK DIAGRAM 6 ALIGNMENT INSTRUCTIONS 7
YOUR REMOTE CONTROL 7 SERVICE MODE ADJUSTMENT 8 ASSEMBLY ADJUSTMENT 10
IC DESCRIPTION 14
UOC III SERIES 14 TDA8358J VERTICAL AMPLIFIER 26 TDA6107AJF 28 24WC16-16 KB EEPROM 29 LA42072N-E AUDIO AMPLIFIER 30
STR-W6735/56 31 WAVEFORMS 33 TROUBLE SHOOTING GUIDE 35
NO POWER 35
NO PICTURE 36
NO SOUND 37
CH DON’T MEMORY or SKIP 38
NO COLOR 39
NO VERTICAL DEFLECTION 39
REMOTE CONTROL DOESNOT OPERATE 40 ELECTRICAL PARTS LIST 41 DIFFERENT PARTS LIST 53 PRINTED CIRCUIT BOARD 56 SCHEMATIC DIAGRAM 59 EXPLODE VIEW 61
TABLE OF CONTENTS
APPENDIX(Appendix is provide only by internet[http://svc.dwe.co.kr])
-2-
SAFETY PRECAUTIONS
CAUTION : DO NOT ATTEMPT TO MODIFY THIS PRODUCT IN ANY WAY. NEVER PERFORM CUSTOMIZED INSTALLATIONS WITHOUT MANUFAC­TURER'S APPROVAL. UNAUTHORIZED MODIFICATIONS WILL NOT ONLY VOID THE WARRANTY, BUT MAY LEAD TO YOUR BEING LIABLE FOR ANT RESULT­ING PROPERTY DAMAGE OR USER INJURY. SERVICE WORK SHOULD BE PERFORMED ONLY AFTER YOU ARE THOR­OUGHLY FAMILIAR WITH ALL OF THE FOLLOWING SAFETY CHECKS AND SERVICING GUIDELINES. TO DO OTHERWISE, INCREASES THE RISK OF POTENTIAL HAZARDS AND INJURY TO THE USER. WHILE SERVICING, USE AN ISOLATION TRANSFORMER FOR PROTECTION FROM A.C. LINE SHOCK.
SAFETY CHECKS
AFTER THE ORIGINAL SERVICE PROBLEM HAS BEEN CORRECTED, A CHECK SHOULD BE MADE OF THE FOLLOWING:
SUBJECT:FIRE & SHOCK HAZARD
1. BE SURE THAT ALL COMPONENTS ARE POSITIONED IN SUCH A WAY AS TO AVOID POSSIBILITY OF ADJACENT COMPONENT SHORTS. THIS IS ESPECIALLY IMPORTANT ON THOSE MODULES WHICH ARE TRANS­PORTED TO AND FROM THE REPAIR SHOP.
2. NEVER RELEASE A REPAIR UNLESS ALL PROTECTIVE DEVICES SUCH AS INSULATORS, BARRIERS, COVERS, SHIELDS, STRAIN RELIEFS, POWER SUPPLY CORDS, AND OTHER HARDWARE HAVE BEEN REINSTALLED PER ORIGINAL DESIGN. BE SURE, THAT THE SAFETY PURPOSE OF THE POLARIZED LINE PLUG HAS NOT BEEN DEFEATED.
3. SOLDERING MUST BE INSPECTED TO DISCOVER POSSIBLE COLD SOL­DER JOINTS, SOLDER SPLASHES OF SHARP SOLDER POINTS. BE CER­TAIN TO REMOVE ALL LOOSE FOREIGN PARTICLES.
4. CHECK FOR PHYSICAL EVIDENCE OF DAMAGE OR DETERIORATION TO PARTS AND COMPONENTS, FOR FRAYED LEADS, DAMAGED INSULATION (INCLUDING A.C. CORD), AND REPLACE IF NECESSARY. FOLLOW ORIGI­NAL LAYOUT, LEAD LENGTH AND DRESS.
5. NO LEAD OR COMPONENT SHOULD TOUCH A RECEIVING TUBE OR A RESISTOR RATED AT 1 WATT OR MORE. LEAD TENSION AROUND PRO­TRUDING METAL SURFACES MUST BE AVOIDED.
6. ALL CRITICAL COMPONENTS SUCH AS FUSES, FLAMEPROOF RESISTOR, CAPACITORS, ETC. MUST BE REPLACED WITH EXACT FACTORY TYPES. DO NOT USE REPLACEMENT COMPONENTS OTHER THAN THOSE SPECI­FIED OR MAKE UNRECOMMENDED CIRCUIT MODIFICATIONS.
7. AFTER RE-ASSEMBLY OF THE STE ALWAYS PERFORM AN A.C. LEAKAGE TEST ON ALL EXPOSED METALLIC PARTS OF THE CABINET. (THE CHAN­NEL SELECTOR KNOB, ANTENNA TERMINALS, HANDLE AND SCREWS) TO BE SURE THE SET IS SAFE TO OPERATE WITHOUT DANGER OF ELECTRI­CAL SHOCK. DO NOT USE A LINE ISOLATION TRANSFORMER DURING THIS TEST USE AN A.C. VOLTMETER, HAVING 5000 OHMS PER VOLT OR MORE SENSITIVITY, IN THE FOLLOWING MANNER : CONNECT A 1500 OHM 10 WATT RESISTOR, PARALLELED BY A .15 MFD. 150V A.C. TYPE CAPACI­TOR BETWEEN A KNOWN GOOD EARTH GROUND (WATER POPE, CON­DUIT, ETC.) AND THE EXPOSED METALLIC PARTS, ONE AT A TIME. MEASURE THE A.C. VOLTAGE ACROSS THE COMBINATION OF 1500 OHM RESISTOR AND .15 MFD CAPACITOR. REVERSE THE A.C. PLUG AND REPEAT A.C. VOLTAGE MEASUREMENTS FOR EACH EXPOSED METALLIC PART. VOLTAGE MEASURED MUST NOT EXCEED .75 VOLTS R.M.S THIS CORRESPONDS TO 0.5 MILLIAMP A.C. NAY VALUE EXCEEDING THIS LIMIT CONSTITUTES A POTENTIAL SHOCK HAZARD AND MUST BE CORRECTED IMMEDIATELY.
SUBJECT : X-RADIATION
1. BE SURE PROCEDURES AND INSTRUCTIONS TO ALL SERVICE PERSON­NEL COVER THE SUBJECT OF X-RADIATION. THE ONLY POTENTIAL SOURCE OF X-RAYS IN CURRENT T.V. RECEIVERS IS THE PICTURE TUBE. HOWEVER, THIS TUBE DOES NOT EMIT X-RAYS WHEN THE HIGH VOLT­AGE IS AT THE FACTORY SPECIFIED LEVEL. THE PROPER VALUE IS GIVEN IN THE APPLICABLE SCHEMATIC. OPERATION AT HIGHER VOLT-AGES MAY CAUSE A FAILURE OF THE PICTURE TUBE OR HIGH VOLTAGE SUPPLY AND UNDER CERTAIN CIRCUMSTANCES, AMY PRODUCE RADIA-TION IN EXCESS OF DESIRABLE LEVELS.
2. ONLY FACTORY SPECIFIED C.R.T ANODE CONNECTORS MUST BE USED.DEGAUSSING SHIELDS ALSO SERVE AS X-RAY SHIELD IN COLOR SETS. ALWAYS RE-INSTALL THEM.
3. IT IS ESSENTIAL THAT SERVICE PERSONNEL HAVE AVAILABLE AN ACCU­RATE AND RELIABLE HIGH VOLTAGE METER. THE CALIBRATION OF THE METER SHOULD BE CHECKED PERIODICALLY AGAINST A REFERENCE STANDARD. SUCH AS THE ONE AVAILABLE AT YOUR DISTRIBUTOR.
4. WHEN THE HIGH VOLTAGE CIRCUITRY IS OPERATING PROPERLY THERE IS NO POSSIBILITY OF AN X-RADIATION PROBLEM. EVERY TIME A COLOR CHASSIS IS SERVICED, THE BRIGHTNESS SHOULD BE RUN UP AND DOWN WHILE MONITORING THE HIGH VOLTAGE WITH A METER TO BE CERTAIN THAT THE HIGH VOLTAGE DOES NOT EXCEED THE SPECIFIED VALUE AND THAT IT IS REGULATING CORRECTLY. WE SUGGEST THAT YOU AND YOUR SERVICE ORGANIZATION REVIEW TEST PROCEDURES SO THAT VOLTAGE REGULATION IS ALWAYS CHECKED AS A STANDARD SERVICING PROCEDURE, AND THAT THE HIGH VOLTAGE READING BE RECORDED ON EACH CUSTOMER’S INVOICE.
5. WHEN TROUBLESHOOTING AND MAKING TEST MEASUREMENTS IN A PRODUCT WITH A PROBLEM OF EXCESSIVE HIGH VOLTAGE, AVOID BEING UNNECESSARILY CLOSE TO THE PICTURE TUBE AND THE HIGH VOLTAGE SUPPLY. DO NOT OPERATE THE PRODUCT LONGER THAN IS NECESSARY TO LOCATE THE CAUSE OF EXCESSIVE VOLTAGE.
6. REFER TO HV, B+ AND SHUTDOWN ADJUSTMENT PROCEDURES DESCRIBED IN THE APPROPRIATE SCHEMATIC AND DIAGRAMS (WHERE USED).
SUBJECT : IMPLOSION
1. ALL DIRECT VIEWED PICTURE TUBES ARE EQUIPPED WITH AN INTEGRA IMPLOSION PROTECTION SYSTEM. BUT CARE SHOULD BE TAKEN TO AVOID DAMAGE DURING INSTALLATION. AVOID SCRATCHING THE TUBE. OF SCRATCHED REPLACE IT.
2. USE ONLY RECOMMENDED FACTORY REPLACEMENT TUBES.
SUBJECT : TIPS ON PROPER INSTALLATION
1. NEVER INSTALL ANY PRODUCT IN A CLOSED-IN RECESS, CUBBYHOLE OR CLOSELY FITTING SHELF SPACE, OVER OR CLOSE TO HEAT DUCT, OR IN THE PATH OF HEATED AIR FLOW.
2. AVOID CONDITIONS OF HIGH HUMIDITY SUCH AS: OUTDOOR PATIO INSTALLATIONS WHERE DEW IS A FACTOR, NEAR STEAM RADIATORS WHERE STEAM LEAKAGE IS A FACTOR, ETC.
3. AVOID PLACEMENT WHERE DRAPERIES MAY OBSTRUCT REAR VENTING. THE CUSTOMER SHOULD ALSO AVOID THE USE OF DECORATIVE SCARVES OR OTHER COVERINGS WHICH MIGHT OBSTRUCT VENTILA­TION.
4. WALL AND SHELF MOUNTED INSTALLATIONS USING A COMMERCIAL MOUNTING KIT, MUST FOLLOW THE FACTORY APPROVED MOUNTING INSTRUCTIONS. A PRODUCT MOUNTED TO A SHELF OR PLATFORM MUST RETAIN ITS ORIGINAL FEET (OR THE EQUIVALENT THICKNESS IN SPAC­ERS)TO PROVIDE ADEQUATE AIR FLOW ACROSS THE BOTTOM, BOLTS OR SCREWS USED FOR FASTENERS MUST NOT TOUCH ANY PARTS OR WIRING. PERFORM LEAKAGE TEST ON CUSTOMIZED INSTALLATIONS.
5. CAUTION CUSTOMERS AGAINST THE MOUNTING OF A PRODUCT ON SLOPING SHELF OR A TILTED POSITION, UNLESS THE PRODUCT IS PROPERLY SECURED.
6. A PRODUCT ON A ROLL-ABOUT CART SHOULD BE STABLE ON ITS MOUNT­ING TO THE CART. CAUTION THE CUSTOMER ON THE HAZARDS OF TRY­ING TO ROLL A CART WITH SMALL CASTERS ACROSS THRESHOLDS OR DEEP PILE CARPETS.
7. CAUTION CUSTOMERS AGAINST THE USE OF A CART OR STAND WHICH HAS NOT BEEN LISTED BY UNDERWRITERS LABORATORIES. INC. FOR USE WITH THEIR SPECIFIC MODEL OF TELEVISION RECEIVER OR GENERICALLY APPROVED FOR USE WITH T.V.S OF THE SAME OR LARGER SCREEN SIZE.
8. CAUTION CUSTOMERS AGAINST THE USE OF EXTENSION CORDS, EXPLAIN THAT A FOREST OF EXTENSIONS SPROUTING FROM A SINGLE OUTLET CAN LEAD TO DISASTROUS CONSEQUENCES TO HOME AND FAMILY.
THE LIGHTNING FLASH WITH ARROWHEAD SYMBOL, WITHIN AN EQUILATERAL TRIANGLE, IS INTENDED TO ALERT THE SERVICE PERSONNEL TO THE PRES-ENCE OF UNINSULATED “DANGEROUS VOLTAGE” THAT MAY BE OF SUFFICIENT MAGNITUDE TO CON­STITUTE A RISK OF ELECTRIC SHOCK.
THE EXCLAMATION POINT WITHIN AN EQUILATERAL TRIANGLE IS INTENDED TO ALERT THE SERVICE PERSONNEL TO THE PRESENCE OF IMPORTANT SAFETY INFORMATION ON SERVICE LITERATURE.
SUBJECT : GRAPHIC SYMBOLS
10WATT
GOOD EARTH GROUND
SUCH AS THE WATER PIPE, CONDUIT, ETC.
1500 OHM
A.C. VOLTMETER
PLACE THIS PROBE ON EACH EXPOSED METAL PART
0.15 uF
-3-
SAFETY PRECAUTIONS
CAUTION : Do not attempt to modify this product in any way. Unau­thorized modifications will not only void the warranty, but may lead to your being liable for any resulting property damage or user injury. Service work should be performed only after you are thoroughly familiar with all of the following safety checks and servicing guide-lines. To do otherwise, increases the risk of potential hazards and injury to the user.
SAFETY CHECKS
After the original service problem has been corrected, a check should be made of the following:
SUBJECT : FIRE & SHOCK HAZARD
1. Be sure that all components are positioned in such a way as to avoid possibility of adjacent component shorts. This is especially important on those chassis which are transported to and from the repair shop.
2. Never release a repair unless all protective devices such as insula-tors, barriers, covers, shields, strain reliefs, and other hardware have been reinstalled per original design.
3. Soldering must be inspected to discover possible cold solder joints, frayed leads, damaged insulation (including A.C. cord), solder splashes or sharp solder points. Be certain to remove all loose for-eign particals.
4. Check for physical evidence of damage or deterioration to parts and components, and replace if necessary follow original layout, lead length and dress.
5. No leads or components should touch a receiving tube or a resistor rated at 1 watt or more. Lead tension around protruding metal sur-faces must be avoided.
6. All critical components such as fuses, flameproof resistors, capaci-tors, etc. must be replaced with exact factory types. Do not use replacement components other than those specified or make unrecommended circuit modifications.
7. After re-assembly of the set always perform an A.C. leakage test on all exposed metallic parts of the cabinet, (the channel selector knob, antenna terminals, handle and screws) to be sure the set is safe to operate without danger of electrical shock. Do not use a line isolation transformer during this test. Use an A.C. voltmeter, having 5000 ohms per volt or more sensitivity, in the following manner : connect a 1500 ohm 10 watt resistor, paralleled by a 15 mfd. 150V A.C. type capacitor between a known good earth ground (9water pipe, conduit, etc.) and the exposed metallic parts, one at a time. Measure the A.C. voltage across the combination of 1500 ohm resistor and 0.15 MFD capacitor. Reverse the A.C. plug and repeat A.C. voltage measurements for each exposed metallic part. Voltage measured must not exceed 0.75 volts R.M.S. This corresponds to 0.5 milliamp A.C. Any value exceeding this limit constitutes a potential shock hazard and must be corrected imme­diately.
The lightning flash with arrowhead symbol, within an equilateral triangle, is intended to alert the service personnel to the presence of uninsu­lated “dangerous voltage” that may be of suffi­cienty magnitude to constitute a risk of electric shock.
The exclamation point within an equilateral tri­angle is intended to alert the service personnel to the presence of important safety information in service literature.
Fuse symbol is printed on pcb adjacent to the fuse, with “RISK OF FIRE REPLACE FUSE AS MARKED”. The symbol is explained in the ser­vice manual with the following wording or equiv­alent.
CAUTION : FOR CONTINUED PROTECTION AGAINST FIRE HAZARD, REPLACE ONLY WITH SAME TYPE (4A, 125V)” and “ATTENTION: AFIN D’ASSU UNE PROTECTION PERMANENTE CONTRE LES RISQUES D’INCENDIE, REMPLACER UNIQUE-MENT PAR UN FUSIBLE DE MEME TYPE ET DE ”4A, 125V”.
SUBJECT : X-RADIATION
1. Be sure procedures and instructions to all service personnel cover the subject of X-rays in current T.V. receivers is the picture tube. However, this tube does not emit X-rays when the high voltage is at the factory specified level. The proper value is given in the appli­cable schematic. Operation at higher voltages may cause a failure of the picture tube or high voltage supply and, under certain cir­cumstances, may produce radiation in excess of desirable levels.
2. Only factory specified C.R.T. anode connectors must be used. Degaussing shields also serve as X-ray shield in color sets. Always re-install them.
3. It is essential that the serviceman has available an accurate and reliable high voltage meter. The calibration of the meter should be checked perio - dically against a reference standard. Such as the one available at your distributor.
4. When the high voltage circuitry is operating properly there is no possibility of an X-radiation problem. Every time a color chassis is serviced, the brightness should be run up and down while monitor­ing the high voltage with a meter to be certain that the high voltage does not exceed the specified value and that it is regulating cor­rectly. We suggest that you and your service organization review test procedures so that voltage regulation is always checked as a standard servicing procedure. And that the high voltage reading be recorded on each customer’s invoice.
5. When troubleshooting and making test measurements in a receiver with a problem of excessive high voltage, avoid being unnecessarily close to the picture tub eand the high voltage compartment. Do not operate the chassis longer than is necessary to locate the cause of excessive voltage.
6. Refer to HV, B+and Shutdown adjustment procedures described in the appropriate schematic and diagrams(where used).
10WATT
GOOD EARTH GROUND
SUCH AS THE WATER PIPE, CONDUIT, ETC.
1500 OHM
A.C. VOLTMETER
PLACE THIS PROBE ON EACH EXPOSED METAL PART
0.15 uF
-4-
SAFETY PRECAUTIONS
SUBJECT : IMPLOSION
1. All direct viewed picture tubes are equipped with an integral implo­sion protection system, but care should be taken to avoid damage during installation. Avoid scratching the tube. If scratched, replace it.
2. Use only recommended factory replacement tubes.
SUBJECT : TIPS ON PROPER INSTALLATION
1. Never install any receiver in closed-in recess, cubbyhole or closely fitting shelf space over, or close to heat duct, or in the path of heated air flow.
2. Avoid conditions of high humidity such as : Outdoor patio installa­tions where dew is a factor. Near steam radiators where steam leakage is a factor, etc.
3. Avoid placement where draperies may obstruct rear venting. The customer should also avoid the use of decorative scarves or other coverings which might obstruct ventilation.
4. Wall and shelf mounted installations using a commercial mounting kit, must follow the factory approved mounting instructions. A receiver mounted to a shelf or platform must retain its original feet(or the equivalent thickness in spacers) to provide adequate are flow across the bottom, bolts or screws used for fasteners must not touch and parts or wiring. Perform leakage test on cus-tomized installations.
5. Caution customers against the mounting of a receiver on sloping shelf or a tilted position, unless the receiver is properly secured.
6. A receiver on a roll-about cart should be stable on its mounting to the cart. Caution the customer on the hazards of trying to roll a cart with small casters across thresholds or deep pile carpets.
7. Caution customers against the use of a cart or stand which has not been listed by underwriters laboratories, inc. For use with their specific model of television receiver or generically approved for use with T.V.’s of the same or larger screen size.
-5-
SPECIFICTION
Model
DTQ-21U6SSV DTQ-21D7SSPV DTQ-2130SSFV
Item
DTQ-21U6SSFV
DTQ-20S1SSFV CHASSIS CN-402FN TV Standard NTSC-M Power Input AC 120V, 60Hz AC 220V, 60Hz AC 100-250V, 60Hz Power Consumption 70W Tuning System Frequency Synthesizer(FS) Tuning System Tuning Ranges TV VHF(L) : CH2 - CH6
UHF(H) : CH7 - CH13 UHF : CH14 - CH69
CATV VHF(L) : 5A, A,B,A-5-A-1,CH2-CH6
VHF(H) : C-W+11,CH7 - CH13
UHF : W+12-W+84 Sound Output 3W + 3W Speaker 8 ohm 7W x 2EA Antenna Input Impedance 75 ohm Unbalanced
Auxiliary Input Terminal Front : Video, Audio(L,R) - AV2
Rear : Video, Audio(L,R) - AV1 Auxiliary Output Terminal Rear : Video, Audio(L,R) - MONITOR OUT Intermediate Frequencies Picture IF Carrier Frequency : 45.75MHz
Sound IF Carrier Frequency : 41.25MHz
Color Sub-Carrier Frequency : 3.579545MHz Remote Control R-48C04(AAA) Special Function 1) Closed Caption
2) V-Chip
3) Channel Label
-6-
CIRCUIT BLOCK DIAGRAM
CN-402FN 21" MODEL for US(With Component Input)
3W 8 ohm
3W 8 ohm
21"
+122V
+195V
+47V
+14V
+47V
+44V
195V
+122V
+44V
7.7V/5V
-7-
ALIGNMENT INSTRUCTION
Your Remote Control(R-48C04)
1. POWER
Use this button to turn your TV on or off.
2. MUTE
Use to turn the TV’s sound on and off.
3. WCHV
Use these buttons to change channels on your TV, or select items in the menu system.
4. C
VOL
B
Use these buttons to change your TV's vol­ume, to activate selections in the menu sys­tem, or to change audio and video settings.
5. MENU
Use this button to turn the TV’s menu system on and off.
6. DISPLAY
Use this button to display the present status.
7. INPUT
Use this button to select the TV’s signal source.
8. VIDEO
Use this button to display video adjustment items.
9. 0-9
Use these buttons to change channels.
10. SLEEP
Use this button to program the TV to turn off after a certain time.
11. PREVIOUS
Use this button to return to the previous chan­nel you were watching.
-8-
ALIGNMENT INSTRUCTION
1. SERVICE MODE ADJUSTMENTS Follow the steps below whenever service adjustment is required. See Table- A and Table- B to determine if service adjustments are required.
1) How to enter the service mode using the user remote control.
- Turn the set on.
- Direct the remote control to the reception window of TV.
- Push buttons of remote control in sequence as follows.
1 →MUTE →DISPLAY →MUTE
- Then, the screen will appear as follows.
SERVICE 02 SERVICE 03 SERVICE 04 SERVICE 05 SERVICE 06 SERVICE 07 SERVICE 08 SERVICE 09 SERVICE 10 SERVICE 11 SERVICE 12
VWSELECT CBADJUST L EXIT
- Using the channel up or channel down button, select the item you wish to adjust. (The color of selected item turns into the blue.)
-
Press the volume up or down button to enter in the service mode you wish to adjust.
2) How to memorize the adjusted values in the service mode.
- Don’t have to press any button the state which the screen is displaying each of service menus after all adjustments are completed each of all service menu.
Table-A : Adjust the values of service mode when a part is replaced.
PART ADJUSTMENT
NOTES
REPLACED NECESSARY UNNECESSARY
I701 O Data is stored in I702.
(U-COM)
Initial setting values are written from I701.
I702 ADJUSTING ITEMS
(EEPROM) O S6 : Geometry adjustmrnt
S8 : White balance S9 : Subbrightness
Adjust items related to picture tube only.
CRT O (White Balance adjustment)
CRT OPTION (Screen Option adjustment)
-9-
ALIGNMENT INSTRUCTION
MODE NAME VAL REMARKS MODE NAME VAL REMARKS
S1 HEAT RUN RUN OFF SOC 0
PWLDAC 0
CL 4
S5 AGC LEVEL 22 CLD 0
IFOFF 37 GAM 1
QSS 1 HCT 0 BPB 1 ACL 0
FMI 1 BPS 0
AGN 0 CHSE 2
BPBS 1 FCO 0
DSG RF:0, AV:1 CBPS 0
Fine Tunning CB 0
FILTBW 0 MUS 0
IDMOD 1 FFI 0
OVMTHR 1 R-GAIN 32
IDMOD SLOW KOR 1 G-GAIN 32
V.SIZE 31 B-GAIN 40
V.CENTER 36 R-BIAS 32
V.SLOPE 33 G-BIAS 32
V.LINEARITY 35 SRC R-BIAS 32
S_CORRECTION 20 SRC G-BIAS 32
H.CENTER 45 CVI R-BIAS 0
H.SIZE 54 CVI G-BIAS 0
H.PARALLEL 44 DP-Brightness 10
H-BOW 35 DP-Contrast 10
PARABOLA 17 DP-Color 5
EW TRAPEZ 38 DP-Sharpness 18
CORNER TOP 54 S10 OPTION
CORNER BOTTOM 46 S12 FACTORY SET
CFCLF 1
YD TV RF:4, AV:7
DTR 0
BPYD 0
TCCON 1
TCI2X 0
PF 3
TFR 1
NRR 0
WS 3 BLS 0 DSK 0 AAS 2 BSD 0 BKS 1 DSA 0 RPO 3 RPA 2 BPD 0
CFA0 1
S9
S8
S6
S7-1
S7-2
DTQ-20S1SSFV EEPROM DATA (050407)
CN-402FN
SCREEN ADJUSTS2 580V
* VOLUME : CENTER (32)
* OPTION 1 : 1110 1001 OPTION 2 : 0110 0011 OPTION 3 : 0000 0010
* SCREEN : 6AE ---> 18 (HEX)
-10-
ALIGNMENT INSTRUCTION
2. ASSEMBLY ADJUSTMENTS
1) SCREEN ADJUSTMENT (S2) Enter the service mode and select service adjustment S2.
You can see the one horizontal line on the screen. Adjust the Screen Control Volume (located on FBT) so that the horizontal line
onscreen may be disappeared.
Press S2 button to exit in the screen adjustment mode.
2) FOCUS ADJUSTMENT Turn in a local station and adjust the Focus Control knob (located on FBT) for best
picture details at high light condition.
3) AGC ADJUSTMENT Adjust the antenna signal level at 60 dBuV
Tune a colour bar pattern. Find the
"AGC"
item in service mode.
(it's two way to entering the
"AGC"
item in service mode)
- Enter the service mode and select service adjustment S5 and select AUTO-AGC.
- Enter the service mode and select service adjustment S3.
Wait until AGC level stabilise to the optimum value. Alternatively,
Enter the service mode and select service adjustment S5 and select AGC LEVEL.
Use "Vol Up/Dwn" keys to adjust manually to the desired Tuner Take Over Point.
4) GEOMETRIC ADJUSTMENTS (S6) Select service adjustment S6
You can see the OSD as shown in below.
V.SIZE 43 H.PARALLEL 33 V.CENTER 42 H-BOW 35 V.SLOPE 28 PARABOLA 17 V.LINEARITY 37 EW TRAPEZ 38
32 CORNER TOP 54 H.CENTER 45 CORNER BOTTOM 46 H.SIZE 54
SELECT ADJUST EXIT
S_CORRECT
-11-
ALIGNMENT INSTRUCTION
4-1) Vertical Position Adjustment.
- Select V.SLOPE item, adjust V.SLOPE data value till the horizontal line in the centre of the video signal is just at the position where the blanking stars.
- Select V.CENTER item, adjust V.CENTER data value to center the raster properly on the screen.
4-2) Vertical Size Adjustment
- Select V.SIZE item, adjust V.SIZE data value to proper vertical size as follows.
4-3) Horizontal Position Adjustment
- Select H.CENTER item, adjust H.CENTER data value to obtain proper horizontal centering of the internal cross pattern at the left and right of the screen.
-12-
ALIGNMENT INSTRUCTION
H.PARALLEL
4-4). H.BOW, PARABOLA Adjustment * Adjust the H.BOW, PARABOLA to compensate for geometrical distortion. * You can not adjust the H.PARALLEL, H.SIZE, EW TRAPEZ, CORNER TOP and CORNER BOTTOM.
-13-
ALIGNMENT INSTRUCTION
5) WHITE BALANCE ADJUSTMENT(S8) Receive a good local channel.
Enter the service mode and select service adjustment S8. You can see the OSD as shown in below.
R-GAIN 32 SRC R-BIAS 32
G-GAIN 32 SRC G-BIAS 32
B-GAIN 40 CVI R-BIAS -8 R-BIAS 32 CVI G-BIAS 10 G-BIAS 32
Using volume up or volume down, adjust service adjustment data of R-GAIN/G-GAIN/B-GAIN and
R-BIAS/G-BIAS until a good gray scale with normal whites is obtained.ALIGNMENT INSTRUCTIONS
6) DIGITAL PRESET(D.P) ADJUSTMENTS(S9)
SUBBRIGHTNESS ADJUSTMENT
Receive a good local channel. Enter the service mode and select service adjustment S9. You can see the OSD as shown in below.
s
10 DP-Contrast 10 DP-Color 5
s
18
Select DP-Brightness item, adjust DP-Brightness data value to obtain normal
brightness level.
DP-Contrast
Fixed value = 10
DP-Color
Fixed value = 5
DP-Sharpness
Fixed value = 18
7) FACTORY OUTGOING MODE (S12 : FACT) If you select the S12, then the set becomes factory outgoing status.
You can see the OSD
"SHIPPING OFF"
SELECT ADJUST EXIT
SELECT ADJUST EXIT
DP-Brightnes
DP-Sharpnes
-14-
IC DESCRIPTION
1-1. UOC III BLOCK DIAGRAM
1. UOC III SERIES
-15-
IC DESCRIPTION
1-2. UOC III FEATURES
-16-
IC DESCRIPTION
-17-
IC DESCRIPTION
-18-
IC DESCRIPTION
Loading...
+ 44 hidden pages