Daewoo DOC-091RH, DOC-091R User Manual

MODE L #:
DOC -091R DOC -091R H
R OOM AIR C ONDIT IONE R US E & C AR E MA NUA L
P OR TA B LE TYP E R OOM AIR C ONDIT IO NE R
P lea se read carefully a nd thoroughly this manua l before opera ting the unit. If you s till ha ve a ny difficulties or problems , cons ult your dealer for help or E LE C TR ON ICS . P lea se keep this manual well.
W1
R
C
US
LI S TE D
UL and
C UL listed
CONTENTS
1.SAFETY RULES.............................................................................
2.NAMES OF PARTS..........................................................................
3.ACCESSORIES................................................................................
4.OPERATION PANEL OF THE AIR CONDITIONER........................
5.OPERATING INSTRUCTION FOR THE AIR CONDITIONER ........
6.INSTALLATION...............................................................................
7.MAINTENANCE...............................................................................
8.TROUBLE SHOOTING....................................................................
1
2
2
3
4
6
7
8
SAFETY RULES
1. DO NOT CONNECT UNIT TO ANY AC SOCKET IN DISREPAIR OR WITH
CONNECTIONS.
2. DO NOT USE IN THE FOLLOWING LOCATIONS:
- NEXT TO SOURCE OF FIRE.
- AN AREA WHERE OIL IS LIKELY TO SPLASH.
- AN AREA EXPOSED TO DIRECT SUNLIGHT.
- AN AREA WHERE WATER IS LIKELY TO SPLASH.
- NEAR A BATH, A SHOWER OR A SWIMMING POOL
- IN THE GREEN HOUSE
3. NEVER INSERT YOUR FINGERS OR ANY FOREIGN OBJECTS INTO THE AIR
OUTLET. TAKE SPECIAL CARE TO WARN CHILDREN OF THESE DANGERS.
4. ALWAYS STORE THE UNIT UPRIGHT IN ORDER TO MAINTAIN THE COMPRE-
SSOR IN A PROPER CONDITION.
5. BE SURE TO UNPLUG THE UNIT BEFORE CLEANING.
6. THE HEATER MUST NOT BE LOCATED IMMEDIATELY BELOW A SOCKET
OUTLET.
7. IF THE APPLIANCE IS COVERED, THERE IS A RISK OF OVERHEAT.
8. IF THE SUPPLY TOOL OF THIS APPLIANCE IS DAMAGED, IT MUST BE
REPLACED BY A REPAIR SHOP APPOINTED BY THE MANUFACTURER,
BECAUSE SPECIAL PURPOSE TOOLS ARE REQUIRED.
NOTE: The air-conditioner can be connected only to a supply with system
impedance no more than 0.4582 ohm. In case necessary, please consult your
supply authority for system impedance information.
1
OPRATION PANEL
AIR OUTLET
NAMES OF PARTS
REAR COVER
FRONT COVER
WATER PUMP
DRAIN HOSE
AIR INLET INDOOR
AIR OUTLET
OUTDOOR
AIR INLET
OUTDOOR
REMOTE CONTROLLER
CASTER
FRONT VIEW
PARTS :
AIR INLET
OUTDOOR
POWER CORD
SIDE VIEW REAR VIEW
Fig.1
ACCESSORIES
PARTS NAME :
DUCT
ADAPTOR A (FOR PERMANENT DUCT
MOUNTING)
ADAPTOR B (FOR TEMPORARY DUCT
MOUNTING)
QUANTITY :
1
1
1
CONTINUOUS
DRAIN HOSE
WALL PLUG
SCREWS
ALKALINE BATTERIES
REMOTE CONTROLLER
WATER PUMP DRAIN HOSE
4
4
2
1
1
Fig.2
Check all the accessories are included in the package and please refer to the installation instructions
for their usage.
2
OPERATION PANEL OF THE AIR CONDITIONER(COOLING AND HEATING)
COOL/DRY/FAN/HEAT INDICATIOR
DIGITAL DISPLAY
TEMP SETTING BUTTON Press your desired room temperature setting by pressing the button (up) or button (down)
INFRARED SIGNAL RECEIVER
FAN SPEED INDICATOR
Green lamp will light when the mode is selected
WATER FULL INDICATOR Red lamp will blink when the tank is full
POWER INDICATOR
POWER BUTTON Turn on/off the unit
TIMER ON/OFF INDICATOR
TIMER ON/OFF BUTTON Program the on/off timer function
OPERATING PANEL
Fig.3
OPERATION PANEL OF THE AIR CONDITIONER(COOLING ONLY TYPE)
DIGITAL DISPLAY
TEMP SETTING BUTTON Select your desired room temperature setting by pressing the button (up) or button (down)
INFRARED SIGNAL RECEIVER
FAN SPEED INDICATOR
COOL/DRY/FAN INDICATOR Green lamp will light when the mode is selected
WATER FULL INDICATOR Red lamp will blink when the tank is full
MODES BUTTON Select the operation mode from COOL.DRY.FAN.HEAT
FAN SPEED BUTTON Select the fan speed from HIGH.MED or LOW
POWER INDICATOR
POWER BUTTON Turn on/off the unit
TIMER ON/OFF INDICATOR
TIMER ON/OFFBUTTON Program the on/off timer function
MODES BUTTON Select the operation mode from COOL.DRY.FAN.
FAN SPEED BUTTON Press the button to select the fan speed from HIGH.MED or LOW
OPERATING PANEL
Fig.4
3
OPERATING INSTRUCTING FOR THE AIR CONDITIONER
Before Starting This Unit
1) Select a suitable location, make sure you have easy access to an electrical outlet.
2) Install the Flexible Exhaust Hose and the Adjustable Window Slider Kit as depicted in Fig.5 & Fig.5a
Fig.5
Fig.5a
NOTE: Step 2 is required only while using the cooling mode
3) Plug the unit into a 115V~60Hz grounded electrical outlet.
4) Make sure the water pump drain hose is correctly installed. ¡¡ 5) Press the on / off button to turn on the unit.
Water pump drain hose
Fig.6
1 BEFORE USE
Dehumidifying and Cooling Operations
- The operating range for cooling operating is 17 C-30 C/63 F-86 F.
OOOO
- If the cooling or dehumidifying operations have been switched off and need switching on again in a short time, allow approximately three minutes for the cooling or dehumidifying operations to resume.
- Make sure the water pump drain hose is correctly connected to the unit. Power supply:
- Insert the AC Power Plug to a AC socket.
- Do not connect the air conditioner to a multiple socket outlet which is also being used for other electrical appliance.
- Be sure the power supply is AC 115V~ 60Hz.
4
2 COOLING OPERATION (Operating temperature range: 17 C-32 C/63 F-90 F)
- Press the "MODE" button several times until the "COOL" indicator light comes on.
- Press the "TEMP SETTING" buttons "" or " " to select your desired room temperature.
OOOO
(17 C-30 C/63 F-86 F)
OOOO
- Press the "FAN SPEED" button to choose the fan speed.
3 DEHUMIDIFYING OPERATION (Operating temperature range: 13 C-32 C/55 F-90 F)
OOOO
- Press the "MODE" button several times until the "DRY" indicator light comes on.
- The fan will run at a fixed speed at this setting.
- Keep windows and doors closed for the best dehumidifying effect.
- Do not put the duct to window.
4 HEATING OPERATION (Cooling only type without heat feature)
(Operating temperature range:5 C-30 C/41 F-86 F)
- Press the "MODE" button several times until the "HEAT" indicator light comes on.
- Press the "TEMP SETTING" buttons "" or " " to select your desired room temperature.
OOOO
(17 C-30 C/63 F-86 F)
OOOO
- Press the "FAN SPEED" button to choose the fan speed.
- Do not put the duct to window.
5 FAN OPERATION
- Press the "MODE" button several times until the "FAN " indicator light comes on.
- Press the "FAN SPEED" button to choose the fan speed.
- Do not put the duct to window.
6 TIMER OPERATION
Setting the on timer:
- Press the "TIMER ON" button when the air conditioner is off. Select the time you need the unit start to operate.
- The Operation Paned Window will display "ON"
- The starting time is adjustable from 0.00 to 24. Setting the off timer:
- Press the "TIMER OFF" button when the air conditioner is on. Select the time you need the unit turn off. The Operation Panel Window will display "OFF".
- The turning off time is adjustable from 0.00 to 24.
7 WATER PUMP DRAINAGE
- Connect the water pump drain hose to the unit before operate. When the water level of the internal water tank reaches a predetermined level, the water pump will be activated and drain the condensed water outside through the connected drain hose. The maximum delivery lift is 3.5m. (Under this condition, attach the rubber blockage to the back hole to prevent continuous drainage.)
8 CONTINUOUS DRAINAGE
- When you plan to leave this unit unused for a long time, remove the rubber blockage form the back hole and attach a section of the continuous drain hose to drain hose connector. All the water in the water tank would drain outside through the drain hose. (Under this condition, the water pump is not activated.)
5
INSTALLATION
1 IMPORTANT:
Install the mobile ir conditioner in a flat and spacious location where the air outlets will not be covered up. A minimum clearance of 30cm from a wall or other obstacles should be kept. The appliance shall not be used in the laundry. The plug shall accessible after appliance is positioned. Wiring shall be done according to National rules.
2 DUCT MOUNT INSTRUCTIONS:
Fig.8
30
cm
Fig.7
Exhaust Air Oulet
Duck
m
c
0
3
A) TEMPORARY-
1. Attach one end of the duct to the exhaust air outlet of the mobile air condition, first fit the left side of the duct on the exhaust air panel, then the right side duct. Push it downwards, be sure to fix thoroughly. (See the figures)
2. Attach the other end of the duct to adaptor B.
3. Put the end of duct to a nearby window.
B) PERMANENT-
1. Attach one end of the duct to the exhaust air outlet of the mobile air conditioner. According to the arrow direction, first fit the left side of the duct on the exhaust air panel, then the right side duct. Push it downwards, be sure to fix thoroughly. (See the figures)
2. Install the adaptor A onto the wall by using 4 wall plug and screws, be sure to fix thoroughly. (See the figures)
3. Attach the other end of the duct to adaptor A.
4. Cover the hole using the adaptor cap when not in use.
The duct can be compressed or extended between 500mm
and 2000mm, but it is desirable to keep the duct length to a
minimum.
IMPORTANT:
DO NOT OVER BEND THE DUCT (SEE FIGURE)
Fig.9
Fig.10
Adapter A
Skruer
Rawlplugs
max 120CM
min 30CM
6
Window Kit Installation
Your window kit has been designed to fit most standard Vertical and horizontal window applications, However, it may be necessary for you to improvise/modify some aspects of the installation procedures for certain types of window. Please refer to Fig. 11 & Fig. 11a for minimum and maximum window openings.
Drain Tank Safety Feature
This unit is equipped with a internal water tank, two full-safe switch mechanisms, one is used to control the water pump drainage, the other is used to monitor the water level inside the internal water tank. When the water level reaches a predetermined level, the full-safe switch mechanism is activated. The digital display shows P1 and the water full indicator light illuminates. Carefully move the unit outside, remove the rubber blockage from the back drainage hole and drain the water off. The unit will continue operating properly.
Horizontal window
Window Slider Kit Minimum:67.5cm(2.22ft). Maxmum:123cm(4.04ft).
Fig.11
Horizontal window
Window Slider Kit Minimum:67.5cm(2.22ft). Maxmum:123cm(4.04ft).
MAINTENANCE
Fig.11a
IMPORTANT:
1) BE SURE TO UNPLUG THE UNIT BEFORE CLEANING.
2) DO NOT USE GASOLING, THINNER OR OTHER CHEMICALS TO CLEAN THE UNIT.
3) DO NOT WASH THE UNIT DIRECTLY UNDER A TAP OR USING A HOSE. THE ELECTRICAL CAUE DANGER.
4) IF THE POWER CORD IS DAMAGED, IT SHOULD BE REPAIRED BY MANUFACTURE OR ITS AGENCY.
1 AIR FILTER
- Clean the air filter at least once every two weeks to prevent inferior fan operation because of dust.
- Removal Pull out the filter cover and remove the air filter from the filter cover.
- Cleaning Wash the air filter by immersing it gently in warm water (about 40 C/104 F) with a neutral detergent. Rinse the
OO
filter and dry it in a shady place.
- Mounting Attach the air filter to the filter cover using the attachment hooks on the inner surface of the cover. Put the filter cover back to the unit.
2 UNIT ENCLOSURE
- Use a lint-free cloth soaked with neutral detergent to clean the unit enclosure. Finished by a dry clean cloth.
Fig.12
7
TROUBLE SHOOTING
TROUBLES
1. UNIT DOES NOT
START WHEN
PRESSING 1/0 BUTTON
2. NOT COOL ENOUGH
POSSIBLE CAUSES
- Water full indicator blinks, water tank
is full.
- Room temperature is higher than
the set temperature.(Heating mode)
- Room temperature is lower than
the set temperature.(Cooling mode)
- The windows or doors in the room
are not closed.
- There are heat sources inside the
room.
- Exhaust air duct is not connected or
blocked.
- Temperature setting is too high.
SUGGEST REMEDIES
Dump the water in the water tank.
Reset the temperature.
Reset the temperature.
Make sure all the windows and
doors are closed.
Remove the heat sources if possible.
Connect the duct and make
sure it can function properly.
Decrease the set temperature.
3. POWER SHUT OFF AT
HEATING MODE
4. NOISY OR VIBRATION
5. GURGLING SOUND
- Air filter is blocked by dust.
- The automatic over heat protection
function. When the temperature at
the air outlet exceed 70 C/158 F,the
device will stop.
- The ground is not level or not flat
enough.
- The sound comes from the flowing
of the refrigerant inside the
air-conditioner.
OO
Clean the air filter.
Switch on again after the unit has cool down.
Place the unit on a flat, level
ground if possible.
It is normal.
8
L imited Warranty
DAE WOO E LE CT R ONIC S AME R IC A, INC . warrants the following Portable room air­conditioner to be free from defective ma terial and workmanship and a grees to remedy any such defect or to furnish a new part (at the C ompanyÕs option) in exchange for any part of a ny unit of its manufacture which under normal installation, us e and service disclos ed s uch defect, provided the unit is delivered by the owner to s tore or dea ler where purcha s ed or Daewoo authorized s ervice center. T o establish and receive warranty s ervice a t our store, dealer or our authorized service center, a s a les receipt or bill of sales is required for proof of purchas e.
This warranty does not extend to any of our electronic products which have been subjected to misus e, neglect, accident, incorrect wiring not our own, improper installation, unauthorized modification, or to us e in violation of ins tructions furnished by us, nor units which ha ve been repaired or altered outside of our factory, nor to ca s es where the serial number thereof ha s been removed, defaced, or cha nged.
This warranty is in lieu of all warranties expressed or implied a nd no repres entative or pers on is authorized to ass ume for us any other liability in connection with the s a les of our electronic products.
Over the counter exchange for units that a re initially defective. Initial defective is des cribed as when the dealer opens the unit and finds that it is inopera tive or an individual customer opening a new unit a nd finding that it is initially defective. T his unit may be returned to the factory by the dealer for exchange. Under no circumstances will an individual customer be permitted to return defective unit directly to factory. E xchange must be directly with the dealer. When this unit is returned to dealer, a copy of the purchase evidence s tating the date of purchase is to be put in the individual box for dealerÕs further control with the factory.
MODE L P AR TS LAB OR C O MPR E S S OR
DO C -091R
1 year 1 year 5 years
DO C -091R H
Note: T he warra nty service center list is constantly changing with the addition of our
current qua lified s ervice centers . If there is inadequate or no local s ervice facility, subject individual cus tomer will ca ll DAE WOO on the toll free number 1-800-DA EW O O8(1-800-323-9668) to be provided with further informations.
Loading...