-6-
ALIGNMENT INSTRUCTIONS
SVC KEY EXPLAIN
(S5) BCL THD : MAX BEAM CURRENT ADJUST,DIFFERENT DATA FOR INCH.
BCL GAIN : AVERAGE BEAM ADJUST.
(S6) GEOMETRY : PAL (50Hz) adjust.
AV NTSC is auto correction.
(S10) NORMAL : PICTURE NORMAL data setting.
(SLEEP) : TXT CHECK ON LINE
(SIZE) : GAME FUNCTION CHECK ON LINE
(S11) OPTION
- HOTEL VOLUME : HOTEL MODE MAX VOL DATA SETTING
- HOTEL MODE OFF : ON--> VOL MAX SET& INSTALL DONT OPERATING
* Software option for Function Change
PIP (ON)
- ON : With PIP Models (xxxxME/MP seiese)
- OFF : Without PIP Models (xxxxMT/MZ seriese)
Digital EYE (ON)
- ON : Enable the Digital Sensor (DTC-29M5xx, KR29M5-xx)
- OFF : Disable the Digital Sensor (DTC-29U1xx, DTC-29U5xx)
LARGE (OFF)
- ON : For 29 inch Models CM-907/F
- OFF : For 14~21 inch Models CM-907S
LATIN : English,French,Swedish,Czech,German,Spanish,Italian,Estonian
EAST: English,Slovakian,Hungarian,Serbian,Albanian,Polish,Turkian,Rumanian
RUSSIA : English,Russian,Bulgaian,Ukrainian,Serbian,Montenegro
TEXT sel. (OFF) PERSIAN : English,Farsi
ARAB : English,Arabic
OFF : Teletext Language depends on OSD Language selection
Note : If OSD language & text selec. is different then Teletext depends on Text selec.
2.The confirmation of Protection circuit
Protection circuit confirmation is omitted in case of mass production in the factory
2-1. Over Current Protecor (OCP) circuit confirmation
2-1-1. Receive PAL RETMA PATTERN(signal of company:2CH., PAL-B) and adjust
STANDARD MODE in PICTURE.
2-1-2. Connect 1M
1/2W between BASE of Q801 and GND, to confirm operating of
PROTECTOR.
The next place, to confirm normal operation when the resister(1M
) is removed.
2-1-3. After Main Power Switch OFF/ON, to confirm normal operation of picture and sound
when turn the set on by remocon.