Dacor SGM466, PGM365, SGM304, SGM364, SGM365 User Manual 2

2” (51mm) to Combustible Rear Wall 0” (0mm) to Non-Combustible Rear Wall
“A”
21”
(533mm)
6” (152mm) Min. from edge of cooktop to combustible side wall above finished countertop (both sides)
19 7/8”
(505mm)
2 3/4” (70mm) to Combustible Rear Wall 3/4” (19mm) to Non-Combustible Rear Wall
Flush with
backside of
cabinet front
“B”
25”
(635mm)
7” Min. from edge of cutout to combustible side wall above finished countertop (both sides)
SGM304, SGM364, SGM365, SGM466
30”, 36”, 46” Wide,
Preference™ Gas Cooktops
OVERALL DIMENSIONS
(PGM304 Shown)
PLANNING
1/2091605
GUIDE
Models “A” Cooktop Width “B” Cooktop Cutout Width
30” 30” (762mm) 27 1/2” (699mm)
36” 36” (914mm) 33 3/4” (857mm)
46” 46” (1168mm) 44 1/2” (1130mm)
Web: http://www.dacor.com Corporate Phone: 800-793-0093
TOP VIEW COUNTERTOP CUTOUT
Specifications are subject to change without notice. See installation instructions for additional details.
4.3
L65335 rev E
30" (762mm) Minimum
from finished countertop to combustible/
non-combustible surface
"C"
18” (457mm) Min.
Both Sides
6” (152mm) Min.
from edge of cooktop
to combustible side wall
above finished countertop
(both sides)
4” (102mm) Chassis height
1/4” (6mm) Min. to combustibles below chassis
Recommended Utility Location
SGM304, SGM364, SGM365, SGM466
30”, 36”, 46” Wide,
Preference™ Gas Cooktops
PLANNING
2/2091605
GUIDE
Models “C” Min. Hood Width “C” Recommended Hood Width
30” 30” (762mm) 36” (914mm)
36” 36” (914mm) 42” (1067mm)
46” 46” (1166mm) 54” (1372mm)
Model
No.
PGM304
SGM304
SGM364 57 lbs.
PGM365
SGM365 1/2” (13mm)
SGM466 76 lbs.
Dedicated
60Hz, 15A
Web: http://www.dacor.com Corporate Phone: 800-793-0093
Circuit
Required
120VAC,
(Breaker)
UPPER CABINET DIMENSIONS
(Upper Cabinets 13” (330mm) Maximum Depth)
Total
Connected
Load
0.03kW (0.25A)
Gas Supply
Requirements
1/2” (13mm)
Regulator -
Natural Gas
Standard
3/4” (19mm)
Regulator -
Natural Gas
Standard
Regulator -
Natural Gas
Standard
Approximate
Shipping
Weight
53 lbs.
67 lbs.
57 lbs.
NOTES:
1. Factory installed liquid propane (LP) special ordered.
2. Cooktop
is supplied with a 48” (1219mm) power
cord, with a three prong grounded plug.
Utilities are located in the right rear corner of the
3. cooktop.
4. See the Combination Installation (CI) Section if
Specifications are subject to change without notice. See installation instructions for additional details.
installing with a downdraft, wall oven, or warming oven.
4.4
L65335 rev E