Dacor SGM304, SGM365, SGM466 User Manual

SGM304, SGM365, SGM466
30"
(762mm)
21"
(533mm)
4" (102mm)
Chassis height
1/4" (6mm) Min. to combustibles below chassis
27 1/2"
(699mm)
19 7/8" (505mm)
3 1/8"
(79mm)
7 1/2" (191mm) Min. to combustible side wall above the cooktop (both sides)
2 1/4" (57mm) Min.
Vertical combustible
surface Rear wall
2"
(51mm) Min.
25" (635mm)
Minimum
Cutout Dimensions for
Model SGM304
36"
(914mm)
21"
(533mm)
19 7/8"
(505mm)
33 3/4"
(857mm)
4" (102mm)
Chassis height
3 1/8"
(79mm)
1/4" (6mm) Min. to combustibles below chassis
7 1/2" (191mm) Min. to combustible side wall above the cooktop (both sides)
2 1/4" (57mm) Min.
Vertical combustible
surface Rear wall
2"
(51mm) Min.
25" (635mm)
Minimum
Cutout Dimensions for
Model SGM365
21"
(533mm)
4" (102mm)
46"
(1168mm)
44 1/2"
(1130mm)
19 7/8" (505mm)
3 1/8"
(79mm)
1/4" (6mm) Min. to combustibles below chassis
7 1/2" (191mm) Min. to combustible side wall above the cooktop (both sides)
Vertical combustible surface
Rear wall
2 1/4" (57mm) Min.
2"
(51mm) Min.
25" (635mm)
Minimum
Cutout Dimensions for
Model SGM466
Revised 07/18/08
Preference™ Gas Cooktops
All tolerances +1/16” -0 (+1.6 mm, 0) unless otherwise noted.
PLANNING
1/2
GUIDE
Web: http://www.Dacor.com Corporate Phone: 800-793-0093
Specifications are subject to change without notice. See installation instructions for additional details.
WARNING
1.
Observe all governing codes and ordinances during planning and installation. Contact your local building department for further information.
This appliance must be installed in accordance
2. with the accompanying installation instructions.
4.9
SGM304, SGM365, SGM466
13"
(330mm)
Max.
A
3 1/8" Min.
(79mm)
30"
(762mm)
Min.
Clearances to Combustibles
18"
(457mm)
Min.
1/4” (6mm) Mimimum clearance to combustible surfaces
B
Under Cabinet Clearances - Front View
Revised 07/18/08
All tolerances +1/16” -0 (+1.6 mm, 0) unless otherwise noted.
Preference™ Gas Cooktops
PLANNING
2/2
Model
SGM304 30” (762mm) 36” (914mm)
SGM365 36” (914mm) 42” (1067mm)
SGM466 48” (1219mm) 54” (1372mm)
“A”
Minimum
GUIDE
“A”
Maximum
SGM304 SGM365 SGM466
Gas Type Natural Gas LP Gas
Manifold Pressure
Min. Gas Supply Pressure **
Total Connected Load
Circuit Requirement
5” Water Column
6” Water Column
60 Hz, 15 Amp
0.25 Amps (0.03 kW)
120 Vac,
SGM304LP SGM365LP SGM466LP
10” Water
Column
11” Water
Column
0.25 Amps (0.03 kW)
120 Vac,
60 Hz, 15 Amp
Model
SGM304 29” (737mm)
SGM365 35 1/4” (895mm)
SGM466 46” (1168mm)
“B”
Minimum
NOTES:
1. Factory installed liquid propane (LP) special ordered.
2. Cooktop is supplied with a 48” (1219mm) power cord, with a three prong grounded plug.
3. Utilities are located in the right rear corner of the cooktop.
4. See the Combination Installation (CI) section if installing with a downdraft, wall oven, or warming oven.
Web: http://www.Dacor.com Corporate Phone: 800-793-0093
Specifications are subject to change without notice. See installation instructions for additional details.
4.10