SGM304, SGM365, SGM466
30"
(762mm)
21"
(533mm)
4" (102mm)
Chassis height
1/4" (6mm) Min.
to combustibles
below chassis
27 1/2"
(699mm)
19 7/8" (505mm)
3 1/8"
(79mm)
7 1/2" (191mm) Min.
to combustible
side wall above
the cooktop
(both sides)
2 1/4"
(57mm) Min.
Vertical
combustible
surface
Rear
wall
2"
(51mm) Min.
25" (635mm)
Minimum
Cutout Dimensions for
Model SGM304
36"
(914mm)
21"
(533mm)
19 7/8"
(505mm)
33 3/4"
(857mm)
4" (102mm)
Chassis height
3 1/8"
(79mm)
1/4" (6mm) Min.
to combustibles
below chassis
7 1/2" (191mm) Min.
to combustible
side wall above
the cooktop
(both sides)
2 1/4"
(57mm) Min.
Vertical
combustible
surface
Rear
wall
2"
(51mm) Min.
25" (635mm)
Minimum
Cutout Dimensions for
Model SGM365
21"
(533mm)
4" (102mm)
46"
(1168mm)
44 1/2"
(1130mm)
19 7/8" (505mm)
3 1/8"
(79mm)
1/4" (6mm) Min.
to combustibles
below chassis
7 1/2" (191mm) Min.
to combustible
side wall above
the cooktop
(both sides)
Vertical
combustible
surface
Rear
wall
2 1/4"
(57mm) Min.
2"
(51mm) Min.
25" (635mm)
Minimum
Cutout Dimensions for
Model SGM466
Revised
07/18/08
30”, 36”, 46” Wide,
Preference™ Gas Cooktops
All tolerances +1/16” -0 (+1.6 mm, 0) unless otherwise noted.
PLANNING
1/2
GUIDE
Web: http://www.Dacor.com
Corporate Phone: 800-793-0093
Specifications are subject to change without notice.
See installation instructions for additional details.
WARNING
1.
Observe all governing codes and ordinances
during planning and installation. Contact
your local building department for further
information.
This appliance must be installed in accordance
2.
with the accompanying installation
instructions.
4.9
SGM304, SGM365, SGM466
13"
(330mm)
Max.
A
3 1/8" Min.
(79mm)
30"
(762mm)
Min.
Clearances to Combustibles
18"
(457mm)
Min.
1/4” (6mm)
Mimimum clearance
to combustible
surfaces
B
Under Cabinet Clearances - Front View
Revised
07/18/08
All tolerances +1/16” -0 (+1.6 mm, 0) unless otherwise noted.
Preference™ Gas Cooktops
30”, 36”, 46” Wide,
PLANNING
2/2
Model
SGM304 30” (762mm) 36” (914mm)
SGM365 36” (914mm) 42” (1067mm)
SGM466 48” (1219mm) 54” (1372mm)
“A”
Minimum
GUIDE
“A”
Maximum
SGM304
SGM365
SGM466
Gas Type Natural Gas LP Gas
Manifold
Pressure
Min. Gas Supply
Pressure **
Total Connected
Load
Circuit
Requirement
5” Water Column
6” Water Column
60 Hz, 15 Amp
0.25 Amps
(0.03 kW)
120 Vac,
SGM304LP
SGM365LP
SGM466LP
10” Water
Column
11” Water
Column
0.25 Amps
(0.03 kW)
120 Vac,
60 Hz, 15 Amp
Model
SGM304 29” (737mm)
SGM365 35 1/4” (895mm)
SGM466 46” (1168mm)
“B”
Minimum
NOTES:
1. Factory installed liquid propane (LP) special
ordered.
2. Cooktop is supplied with a 48” (1219mm) power
cord, with a three prong grounded plug.
3. Utilities are located in the right rear corner of the
cooktop.
4. See the Combination Installation (CI) section if
installing with a downdraft, wall oven, or warming
oven.
Web: http://www.Dacor.com
Corporate Phone: 800-793-0093
Specifications are subject to change without notice.
See installation instructions for additional details.
4.10