PHW Hoods
30” (76.2 cm) or
36” (91.4 cm)
5 3/4”
(14.6 cm)
8” Dia.
203.2 cm)
10 3/4” (27.3 cm)
11 7/8” (30.2 cm)
19 3/4” *
(50.2 cm)
25 3/8” *
(64.5 cm)
26 1/8” (66.4 cm)
Min.*
44” (111.8 cm)
Max.*
19 3/4”
(50.2 cm)
Revised
02/26/08
30”, 36” Wide
Preference™ Hoods
All tolerances: +1/16”, -0, (+1.6mm, -0)
unless otherwise stated
PLANNING
1/2
CHIMNEY MOUNTING BRACKET
5/16”
(0.3 cm)
GUIDE
REAR OF BLOWER UNIT
ALL MODELS
Blower 600 CFM with electronic speed control
Blower
Speeds
Exhaust 8-inch
Required
Required
Web: http://www.Dacor.com
Corporate Phone: 800-793-0093
PHW OVERALL DIMENSIONS
GENERAL SPECIFICATIONS
4
Lights 120 Vac, 50 W halogen (1)
Filters Mesh type, dishwasher safe (2)
Finish
Power
Circuit
430 stainless steel with tempered
glass hood
120 Vac, 60 Hz, 3.5 Amp
120 Vac, 60 Hz, 15 Amp
GLASS
30”
(76.2 cm)
SIDE VIEW
COOKTOP SURFACE
WARNING
The minimum installed distance from the rear of blower unit
base to the cooktop surface must be no less than
30” inches (76.2 cm), 26 inches (66.0 cm) for an electric
cooktop. The minimum specified distance may be higher for the
particular range or cooktop in use. Check the manufacturers
specifications for the cooktop or range.
Specifications are subject to change without notice.
See installation instructions for additional details.
7.9
PHW Hoods
Revised
02/26/08
Calculating the Maximum Duct Run Length
The maximum straight duct length for the hood is 50 feet. For each
elbow and transition added to the duct work, a certain number
of feet must be subtracted from the maximum straight length to
compensate for wind resistance. To determine the length the duct
work cannot exceed, subtract all of the equivalent lengths of the
elbows and transitions listed below from 50 feet.
DUCT PIECE SUBTRACT
90° elbow (8”) 7 feet
45° elbow (8”) 3 feet
3 1/4” x 10” to 8” round 4 feet
Wall cap with damper 30 feet
Roof cap 30 feet
DUCT WORK EQUIVALENT LENGTHS
Preference™ Hoods
30”, 36” Wide
PLANNING
2/2
The hood may exhaust through the ceiling on through a rear wall.
EXAMPLE OF REAR EXHAUST
GUIDE
Web: http://www.Dacor.com
Corporate Phone: 800-793-0093
Specifications are subject to change without notice.
See installation instructions for additional details.
7.10