Dacor PGM304-1, PGM365-1 User Manual

PGM304-1, PGM365-1
30"
(762mm)
21"
(533mm)
4" (102mm)
Chassis height
1/4" (6mm) Min. to combustibles below chassis
27 1/2"
(699mm)
19 7/8" (505mm)
3 1/8"
(79mm)
7 1/2" (191mm) Min. to combustible side wall above the cooktop (both sides)
Vertical combustible
surface Rear wall
2"
(51mm) Min.
25" (635mm)
Minimum
Cutout Dimensions for the PGM304-1
36"
(914mm)
21"
(533mm)
19 7/8"
(505mm)
33 3/4"
(857mm)
4" (102mm)
Chassis height
3 1/8"
(79mm)
1/4" (6mm) Min. to combustibles below chassis
7 1/2" (191mm) Min. to combustible side wall above the cooktop (both sides)
Vertical combustible
surface Rear wall
2"
(51mm) Min.
25" (635mm)
Minimum
Cutout Dimensions for the PGM365-1
Axis2 Axis2
Revised 06/24/08
30”, 36”, 46” Wide,
PLANNING
1/2
GUIDE
Web: http://www.Dacor.com Corporate Phone: 800-793-0093
Specifications are subject to change without notice. See installation instructions for additional details.
4.7
PGM304-1, PGM365-1
13" Max.
(330 mm)
A
3 1/8" Min.
(79 mm)
18" Min.
(457 mm)
30" Min.
(762 mm)
Clearances to Combustibles
1/4” (6 mm) Mimimum clearance to combustible surfaces
B
Under Cabinet Clearances
(Front View)
Revised 06/24/08
30”, 36”, 46” Wide,
All tolerances +1/16” -0 (+1.6 mm, 0) unless otherwise noted.
Model
PGM304-1 29” (737 mm)
PGM365-1 35 1/4” (895 mm)
PLANNING
2/2
GUIDE
“B”
Minimum
Web: http://www.Dacor.com Corporate Phone: 800-793-0093
Model
PGM304-1 30” (762 mm) 36” (914 mm)
PGM365-1 36” (914 mm) 42” (1067 mm)
“A”
Minimum
Dedicated
Model No.
PGM304-1
PGM365-1
Circuit
Required
120 Vac,
60 Hz,
15 Amp
(Breaker)
Total
Connected
Load
0.03 kW
(0.25 Amp)
“A”
Recommended
Gas Supply
Requirements
1/2” (13 mm)
Regulator -
Natural Gas
Standard
3/4” (19 mm)
Regulator -
Natural Gas
Standard
Approximate
Shipping
Weight
53 lbs.
67 lbs.
NOTES:
1. Factory installed propane (LP) special ordered.
2. Cooktop is supplied with a 40” (1016 mm) power cord, with a three-prong grounded plug.
3. Utilities connections are located on the bottm of the chassis at the right rear corner of the cooktop.
4. See the Combination Installation (CI) section if installing with a downdraft, wall oven, or warming oven.
Specifications are subject to change without notice. See installation instructions for additional details.
4.8