Dacor MRV3615S Installation manual

Installation Instructions
Downdraft Vent
HRV46, MRV3015*, MRV3615*, MRV48, MRV3015-ER, MRV36-ER, MRV48-ER
Includes installation instructions for Dacor cabinet blower CABP3, which is an option for the indicated* models.
Part No. 113910 Rev E
Use these downdraft vents only with approved Dacor® appliances. See the instructions in this manual to determine suitability with the companion appliance.
Table of Contents
Important Safety Instructions .......................................... 1
Safety Symbols and Labels
General Safety Precautions ............................................. 2
Product Specifications ..................................................... 2
Electrical Specifications ................................................... 2
Dimensions: MRV3015, MRV3615....................................3
Dimensions: HRV46, MRV48............................................4
Dimensions: MRV3015-ER, MRV36-ER, MRV48-ER......5
............................................. 1
Installation Specifications ................................................ 6
Planning the Installation ................................................... 6
Planning the Duct Work
Installation Instructions .................................................. 12
Installation Preparation .................................................. 12
Installing the Downdraft Vent in the Cutout ................... 13
Verifying Proper Operation Installation Checklist
Wiring Diagram: All Models ............................................ 17
CABP3 Cabinet Blower Ratings ..................................... 17
................................................... 8
............................................. 16
...................................................... 16
Before You Begin...
Installer: In the interest of safety and to minimize problems, read these installation instructions completely and care­fully before you begin the installation process. Leave these installation instructions with the customer.
Customer: Keep these installation instructions for future reference and the local electrical inspector’s use.
Customer Assurance Information
If You Need Help...
For installation or warranty questions/issues, contact Dacor Customer Assurance. Have available the vent’s model and serial numbers, which are on the data label on the front of the unit. This label includes power-supply requirements.
Dacor Customer Assurance: Phone: 833-35-ELITE (833-353-5483) USA, Canada; Mon - Fri 5:00 a.m. to 5:00 p.m. Pacific Time; Website: www.dacor.com/customer-care/contact-us
Model Identification
Use HRV, and MRV downdraft vents with approved Dacor cooktops and ranges only.
Model Number Description
HRV46 46” wide downdraft vent; HRV-style top cap
MRV3015
MRV3015-ER 30” wide downdraft vent; MRV-style top cap
MRV3615
MRV36-ER
MRV48
MRV48-ER
30” wide downdraft vent; MRV-style top cap
36” wide downdraft vent; MRV-style top cap
36” wide downdraft vent; MRV-style top cap
48” wide downdraft vent; MRV-style top cap
48” wide downdraft vent; MRV-style top cap
All specifications subject to change without notice. Dacor assumes no liability for such changes.
© 2018 Dacor, all rights reserved.
Important Safety Instructions
Important Information About Safety Instructions
• The Important Safety Instructions and warnings in this manual do not cover all possible issues. Use common sense and caution when installing, maintaining, or operat­ing the appliance.
• Contact Dacor Customer Assurance about issues and conditions you cannot resolve. (See Customer
Assurance Information.)
DANGER
Do not store/use combustible, flammable substances (e.g., gasoline, alcohol, benzene) in/on/near the vent.
WARNING
TO REDUCE RISK OF PROPERTY DAMAGE AND PERSONAL INJURY, OBSERVE THE FOLLOWING:
a) Installation work and electrical wiring must be done by
qualified person(s) per applicable codes, including fire-rated construction.
b) Sufficient air is needed for proper combustion and
exhaust of gases via the flue of fuel-burning equipment to prevent backdraft. Follow manufacturer guidelines such as are published by the National Fire Protection Association (NFPA); the American Society for Heating, Refrigeration, and Air Conditioning Engineers (ASHRAE); and local code authorities.
c) Know the location of wiring and piping before cutting
or drilling into a wall or ceiling.
d) Fans must always vent to the outdoors.
Safety Symbols and Labels
DANGER
Immediate hazards that WILL result in severe personal injury or death.
WARNING
Hazards or unsafe practices that COULD result in severe personal injury or death.
CAUTION
Hazards or unsafe practices that COULD result in minor personal injury or property damage.
WARNING
The unit has a 3-prong grounding plug to protect against electric shock. It must plug into a dedicated, 3-prong, grounded outlet. The owner shall ensure that such an outlet is available for the appliance. Do not:
• remove the third (ground) prong from the power cord.
• use an adapter plug.
• use an extension cord.
• use a damaged power cord.
• Use a ground fault interrupter (GFI).
READ AND SAVE THESE INSTRUCTIONS
1
Important Safety Instructions
General Safety Precautions
To reduce risk of fire, electric shock, serious injury, or death when using the vent, follow basic safety precautions, including:
WARNING
• Do not install a damaged appliance. If you receive a dam­aged appliance, contact your dealer or builder.
• Observe all governing ordinances during planning and instal­lation. Contact the local building department for details.
• The electrical outlet for the downdraft vent should be installed by a licensed electrician.
• Do not vent hazardous or explosive materials and vapors through the unit.
• Use this downdraft vent only as outlined in the User Manual. The vent is not designed for commercial use.
• The owner should install/repair/replace partts only as specified in the product literature. A qualified technician should perform all other service. Contact Dacor Customer Assurance for examination, repair, or adjustment.
• Keep all packaging away from children.
• For proper operation, install the unit with a cabinet, in-line, or remote blower. Use only a specified model.
Product Specifications
WARNING
• Ensure the vent is unplugged for installation/service.
• The installer must show the customer the outlet so the owner can unplug the vent as needed.
• Install the vent as instructed in this manual, the Dacor range/ cooktop installation instructions, and the blower installation instructions.
• Read the User Manual completely before operating the vent.
• Do not tamper with the vent controls.
• Do not let the filters or vent openings become blocked. Do not let foreign objects be sucked into vent holes.
• Clean the filters and all grease-laden surfaces often to pre­vent grease fires and maintain performance. Clean the appli­ance only as specified in the User Manual.
• Do not leave children/pets unattended near the operating range/cooktop.
• Do not let children play with the downdraft vent.
Electrical Specifications
The downdraft vent comes with a 28” (71.1 cm) power cord with a 3-prong plug. Plug it directly into a 3-prong outlet meeting the requirements below.
The correct voltage, frequency and amperage must be sup­plied as specified below. The circuit must be protected by a properly sized circuit breaker or time-delay fuse.
Electrical-Supply Requirements
A 3-prong outlet connected to a 120 Vac, 60 Hz, 15 Amp. grounded, dedicated, single-phase circuit is required.
• The above specifications are for reference only. If they conflict with spec’s on the product data label, use the spec’s on the label.
• The customer must supply 3 conductor wiring/conduit with minimum 8-Amp current-carrying capacity to sup­ply power to the blower from the downdraft vent. (See Installation Specifications for details.)
• The owner shall ensure the electrical outlet is installed by a licensed electrician. The electrical installation must comply with local ordinances and the latest revision of the National Electric Code ANSI/NFPA 70 (latest revi­sion), a copy of which may be obtained from:
National Fire Protection Association 1 Batterymarch Park Quincy, Massachusetts 02269-9101
• The electrical outlet situated so the vent can be unplugged for service without removing appliances from the cabinet.
2
Product Specifications
Product Dimensions: MRV3015, MRV3615
2 3/16”
(5.6 cm)
5/16” (8 mm) thick stiffener
across back
3”
(7.6 cm)
1 15/16 (4.9 cm)
2 1/8
(5.4 cm)
3/16”
(5 mm)
2 9/16”
(6.5 cm)
Vent shown
in raised
position
*
Top cap with
vent down
9/16”
(1.4 cm)
15"
(38.1 cm)
INSTALLER: To ensure the cooking unit performs properly, seal all seams around the motor cover where it contacts the vent chassis with aluminum tape. (See the graphic below for motor cover location.)
A
Tolerances: ±1/16” (±1.6 mm) unless otherwise stated
Model
A - Top-Cap Width B - Chassis Width
30” (76.2 cm) 27 3/8” (69.5 cm)MRV3015
36” (91.4 cm) 33 3/8” (84.8 cm)MRV3615
IMPORTANT
3/8"
(1.0 cm)
2 1/8" (5.4 cm)
MRV top cap (side view)
See pages 9 and 10 for exhaust locations and dimensions.
20”
(50.8 cm)
3 3/4”
(9.5 cm)
1 1/8” (2.9 cm)
30 1/4”
(76.8 cm)
to
37 1/4”
(94.6 cm)
(76.2 cm)
**
30"
Front of unit
Adjustable
anchor legs
Vent chassis
B
6”
(15.2 cm)
Motor cover
Aluminum tape
Product
data label
28" 3 prong
grounded
power cord
Motor cover
* Total chassis depth with optional CABP3 blower installed is 10 3/8” (26.3 cm).
** Maximum height of downdraft vent must not exceed maximum specified counter height for cooking appliance. See installation instructions for cooking appliance.
3
Product Specifications
Product Dimensions: HRV46, MRV48
Tolerances: ±1/16” (±1.6 mm) unless otherwise stated
5/16” (8 mm)
thick stiffener
across back
2 1/2"
(6.4 cm)
1 15/16" (4.9 cm)
18 5/8”
(47.3 cm)
3 3/4"
(9.5 cm)
1" (2.5 cm)
2 3/16"
(5.6 cm)
2 1/8"
(5.4 cm)
3/16"
(5 mm)
2 9/16"
(6.5 cm)
Vent shown
in raised
position
(76.8 cm)
(94.6 cm)
30 1/4"
to
37 1/4"
9/16"
(1.4 cm)
(25.4 cm)
(76.2 cm)
*
Top cap with
vent down
10"
30"
Model No.
A - Top-Cap Width B - Chassis Width
MRV48 48” (121.9 cm) 43 3/8” (110.2 cm)
HRV46
INSTALLER: To ensure the cooking unit performs properly, seal all seams around the motor cover where it contacts the vent chassis with aluminum tape. (See the graphic below for motor cover location.)
A
46” (116.8 cm) 43 3/8” (110.2 cm)
IMPORTANT
See Pg. 9 for exhaust locations/dimensions.
*Max height of downdraft must not exceed cooking
’s max. specified counter
unit
height. (See cooking unit’s installation instructions.)
B
6"
(15.2 cm)
Motor cover
Front of unit
Product
data label
28" 3-prong
grounded
power cord
Aluminum tape
Motor cover
Adjustable
anchor legs
Vent chassis
3/8"
(1.0 cm)
2 1/8" (5.4 cm)
HRV, MRV top cap (side view)
4
Loading...