Installation Instructions
Millennia ®Electric Range
For use with model MRES30
SAVE AND READ THESE INSTRUCTIONS
CONVENTIONS USED IN THESE INSTRUCTIONS
WARNINGS:
Must be followed carefully to avoid personal injury or damage.
NOTES:
Contain helpful hints and tips to facilitate the installation.
IMPORTANT
1. Before beginning installation, please thoroughly read and become familiar with these instructions.
2. Installation and service must be completed by a qualified installer or service agency.
3. Installer: Please leave these Installation Instructions with the owner.
4. Owner: Please keep these instructions for local electrical inspector's use and for future reference.
5. Read the accompanying use and care manual prior to operating this appliance.
TABLE OF CONTENTS
Important Safety Instructions .......................................................................................................................... Page 1
Electrical Power Supply Requirements .......................................................................................................... Page 2
Product Dimensions ......................................................................................................................................... Page 2
Planning the Location ...................................................................................................................................... Page 3
Cabinet and Countertop Preparation .............................................................................................................. Page 3-4
Verifying the Package Contents ...................................................................................................................... Page 5
Installing the Anti-tip Bracket .......................................................................................................................... Page 5
Removing the Oven Door ................................................................................................................................. Page 5
Removing the Kick Panel ................................................................................................................................. Page 5
Electrical Connection ........................................................................................................................................ Page 5-6
Installing the Range ........................................................................................................................................... Page 7
Re-installing the Oven Door .............................................................................................................................. Page 7
Verifying Proper Operation ................................................................................................................................ Page 7
I
I
Part No. 65166 Rev. K
IMPORTANT SAFETY INSTRUCTIONS
WARNINGS:
1. Read all instructions before
using the appliance.
. If the information in this
manual is not followed exactly,
a fire or explosion may result
causing property damage,
personal injury, or death.
.
Improper installation,
adjustment, alteration,
service or maintenance can
cause personal injury or
property damage. Refer to
these instructions and the
accompanying use and care
manual. For assistance or
additional information, consult
a qualified installer, service
agency or dealer.
.
For your safety:
Do not store or use gasoline
or other flammable vapors and
liquids in the vicinity of this or
any other appliance.
Do not obstruct the flow of
ventilation air to the unit.
Keep appliance area clear and
free from combustible material.
.
This appliance must not
be used in combination
with surface (countertop)
ventilation systems. The use
of an overhead hood, or Dacor
raised vent is recommended
for ventilation.
.
Use this appliance only for
its intended use as described
in this manual. Do not use
corrosive chemicals or vapors
in this appliance. This type of
appliance is not designed for
industrial or laboratory use.
10.
As with any appliance, close
supervision is necessary
when used by children.
11.
Do not operate this appliance
if it has a damaged electrical
cord, plug, conduit or wires,
if it is not working properly,
or if it has been damaged or
dropped.
12.
Installation of this appliance
must be performed by a
qualified installer or service
agency.
13.
This appliance should be
serviced only by qualified
service personnel. Contact the
nearest DACOR authorized
servicer at (800) 793-0093,
or at www.Dacor.com for
examination, repair or
adjustment.
14.
Some products, such as whole
eggs, and sealed containers,
such as closed glass jars, may
explode and should not be
heated on this cooktop.
WARNING:
NEVER cover any slots, holes
or passages in the oven bottom
or cover an entire rack with
materials such as aluminum
foil. Doing so blocks air flow
through the oven and may
cause a fire hazard. Aluminum
foil linings may also trap heat,
causing a fire hazard.
WARNING:
NEVER use this appliance as a
space heater to heat or warm
the room. Doing so may result
in overheating of the appliance.
Range Data Plate Location
The range data plate specifies the model
number, serial number and electrical
supply requirements. It is located on the
left side wall inside the range storage
compartment.
<
6. Disconnect the electrical
supply before installing or
servicing the appliance.
.
This appliance must be
grounded. Connect only to a
properly grounded electrical
supply. Refer to "Electrical
Requirements."
8. Install or locate this appliance
only in accordance with these
installation instructions.
1 _acar
Electrical Power Supply
Requirements
Product Dimensions
It is the owner's responsibility to ensure
that the electrical connection of this
appliance is performed by a qualified
electrician. The electrical installation,
including minimum supply wire size and
grounding, must be in accordance with
the National Electric Code ANSI/NFPA
70-2002* (or latest revision) and local
codes and ordinances.
*A copy of this standard may be obtained
from:
National Fire Protection Association
1 Batterymarch Park
Quincy, Massachusetts 02269-9101
The correct voltage, frequency and
amperage must be supplied to the
appliance from a separate, grounded,
circuit that is protected by a properly sized
circuit breaker or time delay fuse.
Dedicated Total
Electrical Connected
Circuit Required Load
120/240Vac,
4-wire, 60Hz., 50Amp. 10.3kW (48.2Amp.)
Electrical Requirements
The above electrical specifications are for
reference only. See the range data plate
for exact specifications. See page 1 for
location.
[_ WARNING:
If the electric service provided
does not meet the product
specifications, do not proceed
with the installation. Call the
selling dealer or a licensed
electrician.
NOTE:
If the appliance is connected
to a 120/208 volt power supply,
preheat times and cavity
temperature recovery times will
be increased slightly.
Optional full
size side
5/16"- 1 13/16"
(8- 46mm)
Removable (factory
3" (76mm) side panels
60" (1524mm)long
240 Vac 4 wire
conduit location
!
35" '
(889mm)_
!
Dimensions - Isometric View
30"
(762mm)
Range top
Rear of control
Panel/oven door
Door opened
23 2"
(59 Im)
_.5._'16"
345rim',
/
Max. depth
to oven door
handle with
door closed
45 1/4"
(1149mm)
Dimensions - Top View
1
_acar 2
Planning the Location
NOTE:
The shaded areas shown in the
illustrations, denote the location
of the electrical junction box/
receptacle. This is the suggested
location. For replacement
purposes, the location of the
existing electrical supply may be
utilized provided that it does not
interfere with the sides or rear of
the range. Verify that the electrical
service meets local building
codes.
Access to the remote circuit breaker panel/
fuse box, with the range in place and
operating, must also be allowed for in
the installation• Any openings in the walt
behind the appliance and in the floor under
the appliance must be sealed•
36" (914mm) Recommended .___
30" (762mm) Min.
The electrical junction box/receptacle must
be located so that it does not interfere
with the range when it is installed and
under operation• In addition, the junction
box must be located so the range can
be removed for service when the conduit
supplied with the unit is attached to the
junction box. Do not lengthen the conduit
or wiring provided with the range•
All dimensions shown are based on
standard American cabinets 36 inches
(914mm) high at the finished countertop
by 24 inches (610mm) deep, with a 25
inch (635mm) overall countertop depth•
When installing the range into nonstandard
cabinets, minimum clearances shown in
the diagrams must be maintained•
Cabinet and Countertop Preparation
NOTES:
1.
If cabinet storage space is to
be provided directly above
the range, the risk of personal
injury may be reduced by
installing a ventilating hood
that projects horizontally a
minimum of 5 inches (127mm)
beyond the face of the
cabinets.
.
The range may be installed
flush to the rear wall. We
recommend installing a non-
combustible material on the
rear wall above the range
and up to the vent hood. It
is not necessary to install
non-combustible materials
behind the range below the
countertop height.
.
The minimum distance from
the sides of the range above
the countertop to combustible
side walls must be at least 10
inches (254mm).
Utilities may be located:
13"
(330mm
Max.
Hood
1. In the lower left corner of the adjacent
right cabinet• (Recommended)
2. Alternate location, in the lower right
corner behind the range•
Contact your local building department
to verify compliance with local code
interpretation•
10"(254mm) Min.
to combustible side
walls above therange
(both sides)
Freestanding Cabinet Dimensions and Clearances to Combustible Surfaces
3 _acar