MMD24, MMD30 & MMDV30
5"
electrical outlet location
2x4 Anti-
Tip block
(6")
A. 6 "
B. Electrical outlet location
C. Anti-Tip block
D. 5 "
E. 3 1/2"
F. 4"
G. 22 1/4" opening
K. Allow 3/16" minimum overlap
H. 14 3/16" to bottom of Anti-Tip
block
I. Allow 7/8" minimum overlap
J. 23 1/2" minimum depth
Q. 15 3/16" ± 1/16" opening
L. 36" nominal countertop height
M. Allow 7/16" minimum overlap
N. Floor must support 100 lbs.
minimum
O. 19" to top of oor (recommended)
P. 30" cabinet minimum
A
B
C
D
E
F
G
H
I
I
J
K
L
M
N
O
P
Q
G
48" (1219mm)
3-prong
120 Vac power cord
A
B
C
F
I
D
H
E
NOTE: Open Top Cabinet illustrated
MMD24
A. 6 "
B. Electrical outlet location
C. Anti-Tip block
D. 5 "
E. 3 1/2"
F. 4"
G. 28 1/2" opening
K. Allow 1/4" minimum overlap
H. 14 3/4" to bottom of Anti-Tip
block
I. Allow 3/4" minimum overlap
J. 23 1/2" minimum depth
Q. 15 3/16" ± 1/16" opening
L. 36" countertop height
M. Allow 7/16" minimum overlap
N. Floor must support 100 lbs.
minimum
O. 19" to top of oor (recommended)
P. 30" cabinet minimum
MMD30, MMDV30
A. 21 19/32"
B. 4 11/16"
C. 1 23/32"
G. 15 1/16"
H. 1" door thickness
I. 15" auto drawer opening
D. 23 3/8"
E. 23 13/16"
F. 15 5/8"
Power cord length: 48”
MMD30, MMDV30
A. 28 5/16"
B. 4 11/16"
C. 2"
G. 15 1/16"
H. 1 1/4" door thickness
I. 15 1/4" auto drawer opening
D. 23 3/8"
E. 30"
F. 15 5/8"
MMD24
A. 6 "
B. Electrical outlet location
C. Anti-Tip block
D. 5 "
E. 3 1/2"
F. 4"
G. 22 1/4" opening
K. Allow 3/16" minimum overlap
H. 14 3/16" to bottom of Anti-Tip
block
I. Allow 7/8" minimum overlap
J. 23 1/2" minimum depth
Q. 15 3/16" ± 1/16" opening
L. 36" nominal countertop height
M. Allow 7/16" minimum overlap
N. Floor must support 100 lbs.
minimum
O. 19" to top of oor (recommended)
P. 30" cabinet minimum
A
B
C
D
E
F
G
H
I
I
J
K
L
M
N
O
P
Q
NOTE: Open Top Cabinet illustrated
MMD24
A. 6 "
B. Electrical outlet location
C. Anti-Tip block
D. 5 "
E. 3 1/2"
F. 4"
G. 28 1/2" opening
K. Allow 1/4" minimum overlap
H. 14 3/4" to bottom of Anti-Tip
block
I. Allow 3/4" minimum overlap
J. 23 1/2" minimum depth
Q. 15 3/16" ± 1/16" opening
L. 36" countertop height
M. Allow 7/16" minimum overlap
N. Floor must support 100 lbs.
minimum
O. 19" to top of oor (recommended)
P. 30" cabinet minimum
MMD30, MMDV30
Web: http://www.Dacor.com
ANTI-TIP BLOCK LOCATION
Corporate Phone: 800-793-0093
Revised
24”, 30” Microwave In-A-Drawer
06/19/08
NOTES:
1. All tolerances: +1/16”, -0, (+1.6mm, -0), unless
otherwise stated.
2. Spacing between appliances and doors/drawers
is minimum required to allow for ventilation and
to prevent scrapping. Additional space may be
required for appearance.
CUTOUT DIMENsIONs
Model No. Dedicated Circuit Required Total Connected Load
All Models
ELECTRICAL UTILITY LOCATION
120 Vac, 60 Hz, 15 Amp
(Breaker)
ELECTRICAL sPECIfICATIONs
1.56 kW (13 Amp) 128 lbs.
Specifications are subject to change without notice.
See installation instructions for additional details.
OVERALL DIMENsIONs
™
PLANNING
1/1
GUIDE
Approximate
Shipping Weight
12.7