The Important Safety Instructions and warnings in this
manual are not meant to cover all possible conditions and
situations that can occur. Use common sense and caution
when installing, maintaining or operating this or any other
appliance.
®
Always contact the Dacor
problems or situations that you do not understand.
Customer Service Team about
Clearances and Dimensions .......................................................3
Before You Call For Service ....................................................5
ip Block ..............................................................................4
Safety Symbols and Labels
DANGER
Immediate hazards that WILL result in severe personal injury or
death.
WARNING
Hazards or unsafe practices that COULD result in severe
personal injury or death.
CAUTION
Hazards or unsafe practices that COULD result in minor
personal injury or property damage.
InstallatIon recoMMenDatIons
The importance of proper installation of your new appliance
cannot be overemphasized. Installation should be done by
a qualified installer.
Before you begin the installation process, read these
Installation Instructions completely. There are important
details that you need to observeduring installation.
Reading these instructions carefully, will make the
installation process easier, problem-free and safe.
Direct any questions or problems with the installation to
your Dacor dealer or the Dacor Customer Service Team at
(800) 793-0093. Or you may email us at customerservice@
Dacor.com. You can also visit our website at www.Dacor.
com.
IMPORTANT NOTES TO THE INSTALLER
• Read all of the Installation Instructions before installing
the Microwave In-A-Drawer™.
• Remove all packing material before connecting the
electrical supply.
• Observe all governing codes and ordinances.
• Leave these instructions with the consumer.
IMPORTANT NOTES TO THE CONSUMER
Keep these instructions with your use and care manual for
future reference.
• When using any microwave oven generating heat,
there are certain safety precautions you should follow.
These are listed in the use and care manual. Read the
use and care manual and follow all safety precautions
carefully.
• Be sure your Microwave In-A-Drawer™ is installed and
grounded properly by a qualified installer or service
technician.
For SAFETY CONSIDERATIONS do not install drawer in
any combustible cabinetry, which is not in accord with the
stated clearances and dimensions on pages 4 and 5. See
Figures 2 and 3.
1
IMportant safety InstructIons
WARNINGS
If the information in this manual is not followed exactly, a fire or electrical shock may result that could cause property
damage, personal injury or death.
To reduce the risk of tipping, the Microwave In-A-Drawer™ must be secured by a properly installed Anti-Tip block.
This drawer must be electrically grounded in accordance with local codes.
•
• Make sure the wall coverings and the cabinets around the drawer can withstand the heat generated by the
microwave.
Never leave children alone or unattended in the area where a microwave is in use. Never leave the drawer open when
the microwave is unattended.
Stepping, leaning or sitting on the drawer may result in serious injuries and can also cause damage to the Microwave
In-A-Drawer™.
Do not use the drawer as a storage space. This creates a potentially hazardous situation.
•
• Check that the time-of-day is in the display. If not, touch STOP/CLEAR to prevent unintended use.
GROUNDING INSTRUCTIONS
This appliance must be grounded. The Microwave InA-Drawer™ is equipped with a cord having a grounding
wire with a grounding plug. It must be plugged into a
wall receptacle that is properly installed and grounded in
accordance with the National Electrical Code and local
codes and ordinances. In the event of an electrical short
circuit, grounding reduces risk of electric shock by providing
an escape wire for the electric current.
Power supply cord with
three-prong grounding plug
Grounding type wall
receptacle(ground fault
circuit not allowed)
Installer:Leave these installation instructions with this
appliance.
Improper use of the grounding plug can result in a risk of
electric shock.
Have the complete model and serial number for your
microwave available. The numbers are found on the serial
number plate, located on the faceplate behind the drawer
front. Write these numbers below for reference.
A. 6"
B. Electrical outlet location
C. Anti-Tip block
D. 5"
E. 3 1/2"
F. 4"
G. 28 7/16" opening
K. Allow 1/4" overlap
H. 14 3/4" to bottom of Anti-Tip block
I. Allow 3/4" overlap
J. 23 1/2" minimum depth
Q. 15 3/16" ± 1/16" opening
L. 36" countertop height
M. Allow 7/16" overlap
N. Floor must support 100 lbs.
O. 19" to top of floor
P. *30" cabinet minimum
A
B
C
D
E
F
G
H
I
I
J
K
L
M
N
O
P
Q
A
B
C
D
Figure1
DRAWER MEASUREMENTS
Figure 1
CLEARANCES AND DIMENSIONS
• Dimensions that are shown in Figures 2 and 3 must beused. Given dimensions provide minimum
clearance. Locate electrical outlet in the shaded areain the upper left-hand corner of the cutout.
• Contact surface must be solid and level. Pay special attention to the floor on which the drawer will sit.
The floor of the opening should be constructedof plywoodstrong enough to support the weight of the
oven (about 100 pounds).
• Check
• Your oven can be built into a cabinetor wall by itself or under a specific electric wall oven.
location where the drawer will beinstalled for proper electrical supply.
• Be sure that the clearance of the floor between the wall oven and the drawer is a minimum of 2".
• For updates of approved appliances that can be used adjacent to the Microwave In-A-Drawer™ go to
www.Dacor.com.
Figures 2 and 3 contain many Microwave In-A-Drawer™
measurements for reference when planning the drawer’s
location.
Figure 2
3
A
B
C
L
K
J
D
E
G
H
F
I
M
M
N
O
P
Q
R
S
A. 84" wall cabinet
B. Optional wall oven cutout illustrated in
sketch
C. Electrical outlet location
D. 6"
E. Anti-Tip block
F. 3 1/2"
G. 5"
H. 4"
I. 2" minimum
J. 28 7/16" opening
K. Allow 1/4" overlap
L. 14 3/4" to bottom of Anti-Tip block
M. Allow 3/4" overlap
N. 23 1/2" minimum depth
O. 15 3/16" ± 1/16" opening
P. Allow 7/16" overlap
Q. Floor must support 100 lbs.
R. * 19" to top of floor (recommended)
S. 30" cabinet minimum
DesIgn specIfIcatIons
Anti-Tip
block
(6")
ANTI-TIP BLOCK
Normal Installation Steps
Anti-Tip BLOCK Installation Instructions
To reduce the risk of tipping of the drawer, the Anti-Tip
block must be properly installed located 14 3/4" above the
floor on which the Microwave In-A-Drawer™ will sit. The
6" Anti-Tip block must be provided by the installer. See
Figures 2, 3 and 4. The Anti-Tip block prevents serious
injury that might result from spilled hot liquids.
If the drawer is ever moved to a different location, the AntiTip block must also be moved and installed. When installed
to the wall, make sure that the screws completely penetrate
the dry wall and are secured in wood or metal so that the
block is totally stable. When fastening, be sure that the
screws do not penetrate electrical wiring or plumbing.
Figure 4
Figure 3
4
5"
electrical outlet location
2x4Anti-Tipblock
(6")
InstallatIonInstructIons
4 Screws
Parts Supplied
VERIFYING PACKAGE CONTENTS
• Remove all packing materials from inside the drawer.
DO NOT REMOVE THE WAVEGUIDE COVER, which
is located on the top of the Microwave In-A-Drawer™.
• Remove
the feature sticker, if there is one. Check the
drawer for any damage, such as misaligned or bent
drawer, damaged drawer seals and sealing surfaces,
broken or loose drawer guides and dents inside the
cavity or on the front side of the drawer. If there is
any damage, do
not operate the
Sealing
Surface
Microwave InA-Drawer™ and
contact your dealer
Waveguide
Cover
or a DACOR
AUTHORIZED
SERVICER.
Sealing
Surface
Oven
Cavity
Figure 5
ELECTRICAL OUTLET
DRAWER INSTALLATION
Figure 7A
1. Place the drawer adjacent to the wall
or cabinet opening. Plug the power
supply cord into the electrical outlet.
Carefully guide the drawer into the
2.
prepared opening. Avoid pinching the
cord between the oven and the wall.
Slide the drawer all the way until the
3.mounting flange is flush with the face of the cabinet.
4.Open the drawer. Using the 4 holes on the drawer as
a template, predrill the cabinet using a 1/16" bit. See
Figure 7A.
Secure the drawer with the 4 screws supplied. See
5.
Figure 7B.
Figure 7B
Figure 6
The electrical requirements are a 120 volt 60 Hz, AC
only, 15 amp. or more protected electrical supply. It is
recommended that a separate circuit serving only this
appliance be provided.
The drawer is equipped with a 3-prong grounding plug.
It must be plugged into a wall receptacle that is properly
installed and grounded. Should you only have a 2-prong
outlet, have a qualified electrician install a correct wall
receptacle.
NOTE:
If you have any questions about the grounding or electrical
instructions, consult a qualified electrician or service
person.
BEFORE YOU CALL FOR SERVICE
Read the BEFORE YOU CALL and operating instruction
sections in your use and care manual. It may save you time
and expense. The list includes common occurrences that
are not the result of defective workmanship or materials in
this range.
Refer to the warranty in your use and care manual for
Dacor’s toll-free service number and address. Please call
or write if you have inquiries about your microwave product
and/or need to order parts.
5
Web Site: www.Dacor.com
Phone: (800) 793-0093
Specifications contained within are subject to change without notice.
No liability is assumed by DACOR
®
for changes in specifications.
The information and images in this book are the copyright
property of Distinctive Appliances, Inc. Neither this book nor any
information or images contained herein may be copied or used
in whole or in part without the express written permission of
Distinctive Appliances, Inc.