Dacor EHR3012SCH, EHR3018SCH, EHR3612SCH, EHR3618SCH, EHR4212SCH Installation Guide

...
Installation
Epicure®Wall Mount Range Hood
with Remote Blower
For use with models:
EHR30, EHR36, EHR42, EHR48, EHR54
Instructions
PartNo. 103781 Rev. D
APPROVED FOR USE WITH ALL DACOR ®RANGES AND COOKTOPS.
TESTED IN ACCORDANCE WITH THE LATEST EDITION OF ANSI/UL 507
FOR FANS AND VENTILATORS.
Important Safety Instructions .......................................... 1
Important Information About Safety Instructions .............. 1
General Safety Precautions ............................................. 2
Product Specifications .................................................... 3
General Specifications ..................................................... 3
Dimensions ...................................................................... 4
Product Specifications ..................................................... 5
Parts List .......................................................................... 5
Planning the Installation ................................................... 6
Cabinet Layout ................................................................. 6
Power Supply ................................................................... 6
Preparing for Installation .................................................. 8
Verify the Package Contents ............................................ 8
Mounting Location Preparation ........................................ 8
Electrical Service Installation ........................................... 9
Duct Cutout ...................................................................... 9
Installation Instructions .................................................. 10
AHT10 Transition Kit Installation .................................... 10
Mounting Bracket Installation.......................................... 11
Hanging the Range Hood .............................................. 12
Duct Work Installation.................................................... 12
Final Electrical Installation ............................................. 12
Verifying Proper Operation ............................................. 15
Installation Checklist ...................................................... 15
Wiring Diagrams .............................................................. 16
Important:
Installer: In the interest of safety and to minimize problems, read these installation instructions completely and care- fully before you begin the installation process. Leave these installation instructions with the customer.
Customer: Keep these installation instructions for future reference and the local electrical inspector's use.
If You Need Help...
If you have questions or problems with installation, contact your Dacor dealer or the Dacor Customer Service Team. For repairs to Dacor appliances under war- ranty call the Dacor Distinctive Service line. Whenever you call, have the model and serial number of the appliance ready. The model and serial number are printed on the appliance data plate.
Dacor Customer Service Team
Phone: (800) 793-0093 (U.S.A. and Canada) Monday -- Friday 6:00 A.M.to 5:00 P.M.Pacific Time
Web site: www.Dacor.com
Dacor Distinctive Service (for repairs under warranty only)
Phone: (877) 337-3226
Monday -- Friday 6:00 a.m. to 4:00 p.m. Pacific Time
Appliance Data Plate
The appliance data plate contains the model and serial number information and the electrical requirements.
It is located inside the hood behind the filters on the back side of the chas- sis. Remove the filters to view it.
All specifications subject to change without notice. Dacor assumes no liability for changes to specifications.
© 2008 Dacor, all rights reserved.
Important
Information About
Safety Symbols and Labels
Safety
The Important Safety Instructions and warnings in these instructions are not meant to cover all possible
problems and conditions that can occur. Use common sense and caution when installing, maintaining or oper- ating this or any other appliance.
Always contact the Dacor Customer Service Team about problems and conditions that you don't under-
stand.
Instructions
[] DANGER
Immediate hazards that WILL resu t n severe pers0n a
injury or death ........................... I
[_ WARNING
Hazards 0r Unsafe practices that COULD result insevere personal injury or death.
CAUTION
Hazards Or Unsafe practices that COULD result in minor
rsonal injury or property damagel
[_ DANGER
To avoid the PoSsibilitY Ofexplosion 0r fire, do not store or use combustible, flammable or explosive Vapors and liquids (such as gasoline ) inside 0rin the vicinity ofthi s or any other appliance. AIs0 keep items that could explode, such as
aerosol cans away from cooktop burners, ovens and range hoods. Do not store flammable or explosive materials in adjacent cabinets or areas.
WARNING
If the information this manual is not followed exactly, a fire or explosi0n may result causing property damagei personal
injury or death ..................................................................
WARNING
to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.
WARNING
WARNING - TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS. OBSERVE THE FOLLOWING:
a) Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable
codes and standards, including fire-rated construction.
b) Sufficient air is needed for proper combustion and exhausting of gases through the flue(chimney) of fuel
burning equipment to prevent back drafting. Follow the heating equipment manufacturer's guideline and safety
standards such as those published by the National Fire Protection Association (NFPA), and the American
Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities c) When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities. d) Ducted fans must always be vented to the outdoors.
READ AND SAVE THESE INSTRUCTIONS
_mCD_ 1
I [_ CAUTION
Forgenera Vent atng UseOn y.Do notuse toexhausthazardous orexp Os ve matera sand Vaporsl
General Safety Precautions
To reduce the risk of fire, electric shock, serious injury or death when using your appliance, follow basic safety precautions, including the following:
WARNING
Do not. install or operate this hood if it has been damaged, dropped, has damaged electrical wires or is not working properly. If the product is damaged when received, immediately contact the dealer or builder.
This range hood must be installed and grounded by a qualified installer according to these installation instructions.
Install or locate this appliance only in accordance with these installation instructions and the requirements specified by the manufacturer of the cooktop or range. Improper installation, adjustment, alteration, service or maintenance can cause serious personal injury or property damage.
TO REDUCE THE RISK OF FIRE, USE ON_Y METAL DUCTWORK.
The customer should not install, repair or replace any part of the range hood unless specifically recommended in the literature accompanying it. A qualified service technician should perform all other service. Contact the nearest Dacor authorized service representative at (800) 793-0093, or at www.Dacor.com for examination, repair or adjust-
ment
Keep all packaging materials away from children. Plastic bags can cause suffocation.
Do not use an extension cord or adapter plug with this appliance.
The installer must show the customer the location of the fuse box or circuit breaker panel box so that the customer knows where and how to turn the power off.
Before installing or servicing the range hood, switch power off at the fuse box circuit breaker and lock the electri- cal panel door to prevent power from being switched on accidentally. When the electrical panel cannot be locked, securely fasten a prominent warning device, such as a tag, to the electrical panel.
Read the use and care manual completely before using the appliance. Clean the appliance only as instructed in the use and care manual. Use only the cleaners specified.
Do not tamper with the controls.
Never allow the filter(s) to become blocked or clogged. Do not allow foreign objects, such as cigarettes or napkins, to be sucked into the hood.
Clean the filter(s) and all grease-laden surfaces often to prevent grease fires and maintain performance
If the cooktop and range hood are near a window, use an appropriate window treatment. Avoid long drapes or other window coverings that could blow over the cooktop and hood, resulting in a fire hazard.
Always run the fan(s) whenever the cooktop is operating. Never leave the range or cooktop unattended when a burner (or element) is in use. Boil-overs and greasy spills
may smoke and/or ignite.
Do not leave children alone or unattended in the area where the cooktop and range hood are in use. Never allow children to sit or stand on an appliance. Do not let children play with a range, cooktop or range hood. Do not store items of interest to children above or around the cooktop, range or range hood.
The minimum vertical distance between the cooktop surface and the exterior part of the hood must be no less than 30" (76.2 cm). The vertical distance may be longer for the range or cooktop being used. Consult the range or cooktop installation instructions for the minimum and maximum vertical distance from the appliance being used.
2 _mC_
General Specifications
All Models
Fan Speeds 4
Filters Mesh type, dishwasher safe
Exhaust(s) 8-inch
Total Connect
Load
Lights 120 Vac, 75 W halogen
Model Specific
Lights Filters
Exhaust Outputs
120 Vac, 60 Hz, 6.5Amp. Max.
Model Number
EHR48 EHR54
3 2 4 3
2 1
EHR42
EHR30 EHR36
2 2
Weight Specifications
Model
EHR3012
EHR3018, EHR3612
EHR3618 EHR4212 EHR4218
EHR4812 EHR4818 EHR5418
Weight
39 Ibs. (18 kg) 44 Ibs. (20 kg) 48 Ibs. (22 kg) 46 Ibs. (21 kg)
51 Ibs. (23 kg) 52 Ibs. (24 kg) 59 Ibs. (27 kg) 66 Ibs. (30 kg)
_mCD_ 3
Dimensions Tolerances: +1/16",-0 (1.6 mm,-0), unless otherwise stated.
NOTE: The exhaust duct(s) and electrical wiring can be connected from either the top or the back of the hood.
Electrical access holes
7/8" Dia. (5.1 cm)
1 ½" (3.8 cm)
4" (10.2 cm) I
3" (7.6 cm)
Single exhaust models**
Standard 8" duct connection
_ [
,I" % _"
/ \ !
I + II
\ I \
l I II
+
_-- 9 7/8" "-_
19¾"
(50.2 cm
Dual exhaust models*
Standard 8" duct connection
M
\ / \
I! + I
I I I
/ \ /
S % S
(25.1 cm)
Front of
hood
6 1/8"
(15.6 cm)
f
4" (10.2 cm) |
¾,, (1_9 cm) i_1 '
Electrical access holes
7/8" Dia. (5.1 cm)
Bottom of
hood
3" (7.6 cm)
/
/
/
I I _\ I / _'\
I ! +
1 l
\ \
Dual exhaust models*
Standard 8" duct connection
Top Dimensions
19¾" ._
(50.2 cm
9 7/8" --_
(25.1 cm)
l l
I I
I I
I I
Standard 8" duct connection
Back Dimensions
i I \
I +
l
\
l I
I
/
Single exhaust models**
* Models EHR48, EHR54 ** All other models
*** See facing page
D ***
f
4 _mC_
Loading...