Dacor EGR30, EGR30LP User Manual

EGR30
27" (686mm)
26" (660mm)
28 1/2" (724mm)
35 3/4"
(908mm)
to
37”
(940mm)
Finished Side Panel
24 3/8" (619mm)
Rear of Control Panel/Oven Door
Face of Control Panel/Oven Door
Front Edge of Bullnose
Handle
6” (152mm) Backguard
When Backguard and
Side Panels are
removed, the overall
depth decreases
by 1" (25mm)
Accessory 3” (76mm) Side Panels (Dacor Model No. AESP03)
1 9/16"
(40mm)
Revised 07/30/08
30” Wide,
All tolerances +1/16” -0 (+1.6 mm, 0) unless otherwise noted.
Observe all governing codes and ordinances during ◊ planning and installation. Contact your local building department for further information.
This appliance must be installed in accordance with the ◊ accompanying installation instructions.
PLANNING
1/2
WARNING
GUIDE
OVERALL DIMENSIONS
Electrical
Dacor®
Model No.
EGR30
EGR30LP Liquid
Circuit
Required
120 Vac,
60 Hz,
15 Amp
EGR30
SIDE VIEW
Total
Connected
Load
0.75 kW (6Amp)
Gas
Type
Natural 5” Water Column 6” Water Column
Propane
Manifold Pressure
10” Water Column 11” Water Column
Min. Gas Supply
Pressure
NOTES:
1. Utilities may be located in the lower left corner of the adjacent right cabinet. (Recommended)
2. Contact your local building department to verify compliance with local code interpretation.
3. Dacor rear top trim (part #26793; shipped with unit) must be used if backguard and side panels are removed.
4. See the Combination Installation (CI) section if installing with a downdraft.
Web: http://www.Dacor.com Corporate Phone: 800-793-0093
Specifications are subject to change without notice. See installation instructions for additional details.
5.1
EGR30
**
** Cabinet depth is at discretion of customer but cabinet face MUST NOT protrude further than rear of front panel, see product dimesions
* Vertical to combustible surface
B
A
Non-Combustible surface along back wall
Suggested location of utilities
30” (762mm)
min.*
29 1/4" (743mm) 13/32"
(10mm)
30 1/16" (764mm)
3/4" (19mm)
Max. backsplash
1/4" (6mm)
Min. flat ledge
13/16" (21mm)
23 3/16"
(589mm)
Vertical
non-combustible
surface
Rear wall
25"
(635mm)
Revised 07/30/08
30” Wide,
All tolerances +1/16” -0 (+1.6 mm, 0) unless otherwise noted.
PLANNING
2/2
GUIDE
Model Number “A” Cabinet Width “B” Hood Width
EGR30 30 1/16” (764mm) 30” (762mm)
CABINET DIMENSIONS
Web: http://www.Dacor.com Corporate Phone: 800-793-0093
Countertop
Countertop
TOP VIEW
(Slide-In, Self-Rimming Installation with Side Panels and Backguard Removed)
CUTOUT DIMENSIONS
Specifications are subject to change without notice. See installation instructions for additional details.
5.2