CombINATIoN INsTALLATIoNs
Non combustible rear
wall recommended
10” (254 mm) Min. to
combustible wall
above countertop,
both sides
Cabinet face
below countertop
overhang
3/8” (10 mm) Min.
countertop overhang
2 5/8”
(67 mm)
Hole 1/2” dia. (13 mm),
2 places, through platform
for hold down bolts
1/2” (13 mm)
countertop
overhang
1” thick mounting platform Min.
Open to below to allow for raised
vent, gas and electrical connections
Countertop
Countertop
1/2” (13 mm)
countertop
overhang
2” (51 mm)
1” (25 mm)
11 7/16”
(291 mm)
15”
(381 mm)
24 5/8”
(625 mm)
C
L
D
D
E
B
C
L
C
L
C
L
Stiffener
Cabinet face
Control panel
Countertop
Dacor approved
raised vent
IMPORTANT: See raised vent
installation instructions for
duct system layout/planning
EG366 or EG486 cooktop
3/8” Min. (10 mm)
space behind
raised vent
chassis to clear
stiffener
3/8” Min. (10 mm)
flat countertop overhang
required behind cutout
Minimum
countertop
height:
30 1/4"
(768 mm)
Document # PGCI-001 Revised 09/09/09 Page 1/1
EG series slide-in Cooktop
with Erv/Prv series slim raised vent
WARNING
Observe all governing codes and ordinances during •
planning and installation. Contact your local building
department for further information.
All appliances must be installed in accordance with •
the accompanying installation instructions.
Model
No.
EG366 ERV36, PRV36
EG486 ERV48, PRV48
IMPORTANT: Use only approved raised vent models
Model
No.
EG366
EG486
B - Cutout
Width
(914 mm)
(1219 mm)
Approved Raised
36”
48”
Vent Models
D - Hole
Offset
16 5/8”
(422 mm)
20 13/16”
(529 mm)
E - Raised
Vent Cutout
33 1/2”
(851 mm)
43 1/2”
(1105 mm)
PLANNING
GUIDE
Cutout tolerances: +1/16”, -0, (+1.6 mm, -0) unless otherwise stated
EG series cooktop
All specications subject to change without notice.
Install all appliances according to accompanying installation instructions.
CAbINET/CoUNTErToP CUToUT DImENsIoNs
wITH rAIsED vENT - sIDE vIEw
CAbINET/CoUNTErToP CUToUT DImENsIoNs wITH rAIsED vENT - ToP vIEw
www.Dacor.com Phone: (800) 793-0093