EG366, EG486
4” (102 mm)
5/8”
(16 mm)
7 3/4”
(197 mm)
Trim:
7/16”
(11 mm)
thick
26” (660 mm)
1 1/2” (38 mm) cooking surface
height (grate level) above
countertop
3/4” gas inlet, connects to regulator from
bottom or rear of unit, end is recessed
2” (51 mm) from chassis bottom
27” (686 mm)
28” (711 mm)
Power cord
32” long
Combustible
rear wall
Backguard mandatory if
gap from back of cooktop
to combustible wall is less
than 2 1/2”
Combustible
rear wall
2 1/2” (64 mm) Min. to
combustible rear wall
Document # PG04-001 Revised 05/06/10 Page 1/4
36 Inch and 48 Inch Wide
Epicure® Gas Cooktops
WARNING
Observe all governing codes and ordinances during planning •
and installation. Contact your local building department for
further information.
This appliance must be installed in accordance with the •
accompanying installation instructions.
Product tolerances: ±1/16” (±1.6 mm) unless otherwise noted
PLANNING
GUIDE
ELECTRIC CIRCUIT REQUIREMENTS
Circuit Required Total Connected Load
120 Vac 60Hz, 15 Amp. (3 wire) 0.25 Amp @ 120 Vac, 60 Hz
GAS SUPPLY PRESSURE REQUIREMENTS*
Gas Type Manifold Pressure
Natural Gas 5” Water Column 6” Water Column
Propane (LP) 10” Water Column 11” Water Column
* Maximum gas supply pressure for all models is 1/2 p.s.i.
IMPORTANT: Installation of a non-combustible material* (up to the hood) or
a backsplash is always recommended, and mandatory if the distance to the
back wall from the cooktop is less than 2 1/2” (Figure 2). When installing a
backguard, use only Dacor model numbers AEB3609, AEB3612 (EG366),
AEB4809 or AEB4812 (EG486).
Minimum Gas Supply
Pressure
PRODUCT DIMENSIONS - ISO VIEW
A - Width
EG366 35 7/8” (911 mm)
EG486 47 7/8” (1216 mm)
Specications subject to change without notice.
Install all appliances according to accompanying installation instructions.
PRODUCT DIMENSIONS - SIDE VIEW
CABINET/COUNTERTOP SIDE VIEW WITHOUT BACKGUARD
CABINET/COUNTERTOP SIDE VIEW WITH BACKGUARD
www.Dacor.com Phone: (800) 793-0093
4.1

See note 2
2
See Cabinet/Countertop Dimensions - Top View
3
Not applicable for cabinets more than a horizontal
distance of 10” (254mm) from the edge of the cooktop.
1
Vertical to combustible surface from cooktop grate level;
if installing an overhead vent hood, also check the hood
specifications for minimum required clearances.
C
13” (330 mm)
max.
3
Top of
finished
counter
18” (457 mm)
Min.
1, 3
30” (762 mm)
Min.
1
Cutout for
utility access
Hood
Recommended
gas and electrical
service location,
consult local code
B
10” (254 mm) to
combustible side
wall Min. both sides
1/2” (13 mm)
overhang,
both sides
1 1/2” (38 mm)
typical countertop
thickness
7 3/4”
(197 mm)
36” (914 mm)
typical
Cooktop platform
1” (25 mm) Min.
thickness
EG366, EG486
Document # PG04-001 Revised 05/06/10 Page 2/4
36 Inch and 48 Inch Wide
Epicure® Gas Cooktops
Cabinet tolerances: +1/16”, -0 (+1.6 mm, -0) unless otherwise noted.
CABINET/COUNTERTOP DIMENSIONS - FRONT VIEW
PLANNING
GUIDE
Model No. B C
EG366 36” (914 mm)
EG486 48” (1219mm)
* Minimum ** Recommended
CABINET/COUNTERTOP DIMENSIONS -
ISO VIEW
36” (914 mm)*
42” (1067 mm)**
48” (1219 mm)*
54” (1372 mm)**
Specications subject to change without notice.
Install all appliances according to accompanying installation instructions.
www.Dacor.com Phone: (800) 793-0093
Continued on following pages...
4.2