Dacor EG366 User Manual

EG366, EG486
Revised 01/30/08
A
PRODUCT DIMENSIONS
COOKTOP WIDTH (A)
EG366 35 7/8” (911mm)
EG486 47 7/8” (1216mm)
All tolerances: +1/16”, -0 (+1.6mm, -0)
36”, 48” Wide,
4” (102mm)
Power Cord
29” (737mm) long
PLANNING
1/4
A 28” (711mm)
B 27” (686mm)
C 26” (660mm)
SIDE VIEW
A Rear of trim to front of knobs
B Rear of trim to front of bull nose
C Rear of trim to front of control panel
D Bottom of chassis to bottom of trim
GUIDE
5/8” (16mm)
Combustible
rear wall
D 7 3/4”
(197mm)
ELECTRIC CIRCUIT REQUIREMENTS
Circuit Required Total Connected Load
120VAC
60Hz, 15A
GAS SUPPLY PRESSURE REQUIREMENTS
Gas Type Manifold Pressure
Natural Gas 5” Water Column 6” Water Column
Propane (LP) 10” Water Column 11” Water Column
24.0W (0.2A)
Minimum Gas Supply
Pressure
2 1/2” (64mm) Min. to
combustible rear wall
SIDE VIEW
Combustible
rear wall
Backsplash mandatory
if gap from back of
cooktop to combustible
wall is less than 2 1/2”
Web: http://www.Dacor.com Corporate Phone: 800-793-0093
SIDE VIEW WITH BACKSPLASH
Specifications are subject to change without notice. See installation instructions for additional details.
4.3
EG366, EG486
C
L
10” (254mm) to
combustible side wall
minimum, both sides
Revised 01/28/08
36”, 48” Wide,
B
Hood
1 1/2” (38mm)
5/8” (16mm)
Overhang, both sides
Typical countertop
thickness
PLANNING
2/4
GUIDE
18” (457mm)
Minimum
30” (457mm)
Minimum
1” (25mm) Minimum
Model No. “B” “C” “D”
EG366
EG486
Web: http://www.Dacor.com Corporate Phone: 800-793-0093
Cooktop platform
thickness
6” (152mm)
36” (914mm)*
42” (1067mm)**
48” (1219mm)*
54” (1372mm)**
C
Gas and electrical service
location
D
CUTOUT DIMENSIONS
36” (914mm) 24” (610mm)
48” (1219mm) 30” (762mm)
* Minimum
** Recommended
All tolerances: +1/16”, -0 (+1.6mm, -0)
Specifications are subject to change without notice. See installation instructions for additional details.
7 3/4”
(197mm)
2 3/4”
(70mm)
15 1/2”
(393mm)
NOTE:
1. POWER CORD IS 29” LONG
36” (914mm)
Continued...
4.4
Loading...