DWR30M977WIP/WIM/WIS
Doc #:PGM-DWR.01 Revised 29 Jan 2019 Page 1 of 4
All tolerances: ±¹/₁₆” (±1.6 mm), unless otherwise stated.
Modernist
WARNING
• Observe all governing codes and ordinances during planning/
installation. Contact your local building department for details.
• The drawer must be installed as directed in its installation
instructions.
®
Warming Drawer
Electrical Circuit Required Total Connected Load
PLANNING
GUIDE
Min. Ambient
Operating Temp.
Front Panel for WIM/WIS Shown
120Vac, 60 Hz, 15 Amp
grounded, dedicated circuit
4.0 Amp. @
120Vac, 60 Hz
32°F (0°C)
Front Panel for WIP Front Panel for WIM/WIS
Model No.
DWR30M977
All specications subject to change without notice. www.dacor.com Ph. 800.793.0093
(A)
Chassis Face
Width
29 5/8”
(75.2 cm)
(B)
Chassis
Width
27 7/8”
(70.8 cm)
(C)
Chassis
Depth
20 15/16”
(53.1 cm)
(D)
Drawer Depth
(without panel)
19 3/4”
(50.2 cm)
(D)
Drawer Depth
(with 3/4” panel)
20 1/2”
(52.1 cm)
(E)
Chassis Height
(with feet)
9 3/4”
(24.8 cm)
DWR30M977WIP/WIM/WIS
All tolerances: ±¹/₁₆” (±1.6 mm), unless otherwise stated.
Page 2 of 4
Modernist
®
Warming Drawer
Mounting platform must be ¾" (1.9 cm) thick and able to support
100 lbs. (45.4 kilos)
PLANNING
GUIDE
Measurement DWR30M977
(A) Cutout Width 30 1/4” (76.8 cm)
(B) Min. Width to Adjacent Doors/
Drawer
(C) Cutout Height 10 1/2” (26.7 cm)
(D1) Min. Vertical Gap Betw. Warming Drawer Cutouts
(D2) Min. Vertical Gap Betw.
Dacor Wall Oven
(E1) Flush to Drawer Front 1 5/64” (2.7 cm)
(E2) Flush to Cab’t Frame /
Drawer with Panel Flush to
Drawer Front
(E3) Drawer with Panel
Flush to Cab’t Frame
(E4) Drawer with Oversized
Panel
(F) Min. Width Inside Cleats 28” (71.0 cm)
(G) Min. Cutout Depth 24” (61.0 cm)
30 1/4” (76.8 cm)
1 1/4” (3.2 cm)
1 1/2” (3.8 cm)
1 53/64” (4.6 cm)
2 37/64” (6.5 cm)
1 37/64” (4.0 cm)
All specications subject to change without notice. www.dacor.com Ph. 800.793.0093