Dacor DTCT466GBLP Planning Guide

Document # PG04-008
DTCT304, DTCT365, DTCT466
Revised 11/05/15 Page 1/3
Distinctive® 30”, 36” and 46” Wide
Drop-in Gas Cooktops
WARNING
Observe all governing codes and ordinances during planning and installation.
Contact your local building department for further information. This appliance must be installed in accordance with the installation instructions supplied with the unit.
All tolerances: ±1/16” unless otherwise noted.
21 in
(53.3 cm)
36 in
(91.4 cm)
30 in
(76.2 cm)
19 1/2 in *
(49.5 cm)
PLANNING
GUIDE
Model DTCT304G
1 5/8 in (4.1 cm)
bottom of base
to cooking surface
4 in (10.2 cm)
chassis height
27 5/8 in *
(70.2 cm)
Model DTCT365G
1 5/8 in (4.1 cm)
bottom of base
to cooking surface
21 in
(53.3 cm)
19 1/2 in *
(49.5 cm)
1 5/8 in (4.1 cm)
bottom of base
to cooking surface
21 in
(53.3 cm)
19 1/2 in *
(49.5 cm)
33 1/2 in *
(85.1 cm)
46 in
(116.8 cm)
4 in (10.2 cm)
chassis height
Model DTCT466G
4 in (10.2 cm)
chassis height
44 5/8 in *
(113.3 cm)
* including raised embosses on sides of chassis
All specications subject to change without notice.
Phone: (800) 793-0093www.dacor.com
4.22
Document # PG04-008
DTCT304, DTCT365, DTCT466
Revised 11/05/15 Page 2/3
Distinctive® 30”, 36” and 46” Wide
Drop-in Gas Cooktops
Electrical Requirements
WARNING
To prevent an electric shock hazard, the power supply must meet the specifications stated below. It is the owner’s responsibility to make sure that the electrical service meets electrical requirements and that the electrical outlet has been properly installed by a licensed electrician.
◊ The cooktop is supplied with a factory installed, 40-inch,
three-prong, grounding electrical plug. It is connected to the chassis at the bottom right rear corner.
Refer to the figure Chassis Bottom below.
◊ The cooktop must be connected to a dedicated, grounded
three-prong electrical outlet installed by a licensed electrician.
◊ The electrical installation, including the supply wire size and
grounding, must be done in accordance with National Electric Code ANSI/NFPA 70* and local codes and ordinances. A copy of this standard may be obtained from:
National Fire Protection Association 1 Batterymarch Park Quincy, MA 02269-9101
◊ The correct voltage, frequency, and amperage must be
supplied to the electrical outlet according to the product data label located on the bottom of the chassis.
◊ See the table Gas and Electrical Requirements on this
page for reference.
◊ Be certain to choose an electrical outlet with easy access so
that the power cord may be disconnected if the unit needs service.
PLANNING
GUIDE
Gas Supply Requirements
◊ Ensure that the cooktop is correct for the gas being provided (natural
gas or LP gas). Also, if using the cooktop at an altitude above 4000 ft. (1219 m), make sure it is equipped for high altitude operation.
◊ Units equipped for LP operation have “LP” in the model number
listed on the product data label. See the figure Chassis Bottom for the label location.
◊ Units equipped for high altitude operation have an “H” at the end of
the model number listed on the product data label.
◊ Check your local building codes for the proper method of installation.
In the absence of local codes, this appliance should be installed in accordance with the National Fuel Gas Code ANSI Z223.1/NFPA 54.
◊ An external manual shut-off valve must be installed between the gas
inlet and the cooktop for the purpose of turning on or shutting off gas to the appliance.
◊ The cooktop comes from the factory with a regulator in the shipping
carton. The regulator must be installed in the gas line that runs from the cooktop gas inlet to the gas shut-off valve. Use only the regulator provided.
◊ Models DTCT304G and DTCT365G have a 1/2-inch regulator.
Model DTCT466G has a 3/4-inch regulator, approved for connection to a 1/2 inch house gas supply.
The cooktop gas connection is located on the bottom of the cooktop, in the back right corner as you face the front of the unit. See the figure Chassis Bottom on this page.
DTCT304G
Model Number
Gas Type Natural Gas LP Gas
Manifold Pressure
Min. Gas Supply Pressure **
Max. Gas Supply Pressure
Total Connected Load
Circuit Requirement
DTCT365G DTCT466G
4” Water
column
5” Water
column
1/2 psi 1/2 psi
0.25 Amp. (0.03 kW)
120 Vac,
60 Hz, 15 Amp.
DTCT304LP DTCT365LP DTCT466LP
10” Water
column
11” Water
column
0.25 Amp. (0.03 kW)
120 Vac,
60 Hz, 15 Amp.
Product data label
3-prong plug
Chassis Bottom
All specications subject to change without notice.
Gas inlet
Gas and Electrical Requirements*
* The electrical and gas data on this page is for reference only. If the
above data does not agree with the product data label, use the data on the product data label.
** The gas supply pressure for testing the regulator setting shall be at least 1-inch water column (249 Pa) above the specified manifold pressure.
Phone: (800) 793-0093www.dacor.com
4.23
Loading...
+ 2 hidden pages