It is important to observe the specified dimensions of the installation cutout for a
trouble-free installation of the appliance and for the subsequent appearance of the door
panel.
- In particular ensure that the cutout is square. Squareness can be checked by suitable
means, spirit level diagonal measurements, etc.
- This side walls of the cutout must be flush. The minimum thickness of the side and top
walls is 5/8” (16 mm).
2. Plan the cutout : Single
Call Out 18”24”30”36”42”
A (Cabinet Width)
B (Cabinet Depth)
• B : Includes the standard door panel thickness with 3/4”.
• Installation inside a cabinet of this width allows the refrigerator trim to be attached
directly to the surrounding cabinets.
Min 25” (635 mm)
84” (2134 mm)
9
DACOR built-in refrigeration appliances are designed to accommodate nearly any type
of kitchen cabinetry door installation. Generally, when using standard ¾”(19mm)panels,
Min 25”(635mm) deep cutout are recommended.
2. Plan the cutout : Single
* Furniture Return
Back wall
84”
(2134mm)
25”
(635mm)
Furniture Return
Min. 4inch
(102mm)
Face Cabinet
Min 4”
(102mm)
Back wall
25”
(635mm)
10
Furniture Return
Furniture return must be at least 4" (102 mm) deep, on interior top and sides,
of solid material and should be finished to match the exterior at the same depth (4" or 102 mm)
3. Plan the configuration & cutout : Pair / 3 unit
1) Recommend configuration
OK OK X
Column Column Column
Single
* Without Partition
3. Plan the configuration & cutout : Pair / 3
Pair
OK
Column Column
X ( not possible pairing ) X ( not possible pairing )
Column Column
X ( not possible pairing )
X ( not possible pairing )
Column Column
Column FDR or T
unit
FDR or T FDR or T
11
3. Plan the configuration & cutout : Pair / 3 unit
1) Recommend configuration
* With Partition
Door swivel direction : Opposite
The minimum thickness of the partition is 1 1/4” (32mm).
OK
Column Column
3. Plan the configuration & cutout : Pair / 3
Pair
Screw
Door swivel direction : Same
The minimum thickness of the partition is 1 9/16” (40mm).
OK
Column Column
OK
FDR or T
Column Column
Column
OK
Screw
unit
Column
OK
FDR or T
12
Loading...